Rewrite STATUS Pending section to match the audit's phased action plan (§11)
exactly. Remove stale "wnode-tsys6 D5->S4, wnode-tsys7 D5->S1" line (wnode6
already on S4, wnode7 on S3, S1 is not a target). Fix section reference (§12 ->
§11). Correct actual-usage percentages (73%/37%/62%) and CPU idle range (0-5%).
Add D2 IOPS hotspot as a known issue. Fix sectestbed suite count in audit (x9 ->
x10). Verified all VM counts and host data against fresh ground truth.
💘 Generated with Crush
Assisted-by: Crush:glm-5.2
8.0 KiB
Project Status
Human read-only. Agents maintain this file automatically after each work session. Do not edit by hand — the next agent run will overwrite it.
Last updated: 2026-07-29 by Crush (GLM-5.2)
Capacity targets are now codified in
proxmox/docs/CAPACITY-GOALS.md: 80% RAM steady-state, ~50% idle CPU. The current placement analysis lives inproxmox/docs/AUDIT-2026-07-29.md.
Current State: STABLE
The merged PFVCluster repo is fully operational across provisioning, DNS infrastructure, Proxmox cluster ops, and k8s control plane.
Completed Work
Server Provisioning (validated on sectestbed-sandbox)
- SetupNewSystem.sh deploys end-to-end to rc=0 (Debian 13 trixie)
- Security hardening: SSH, SCAP-STIG, Wazuh, 2FA (SSH+Cockpit+Webmin)
- NTP: redundant pfv-netinfra-01/02 (192.168.3.252/253), synced stratum 3
- DNS resolv.conf: managed static file pointing at netinfra pair
- Test suite: 5 tests (framework, safe-download, 2fa, https, system-req)
- VM validation harness: git-based deploy + auto-rollback + guest-agent access
DNS Cluster (pfv-netinfra-01/02)
- Production Technitium config replicated from tailscale-router (read-only)
- 124 zones on both nodes (knel.net + reverse DNS)
- pfv-netinfra-01 = PRIMARY, pfv-netinfra-02 = SECONDARY
- Zone replication via rsync systemd timer (every 60s)
- Credentials + 2FA replicated identically to production
- Both LAN IPs resolve knel.net device names + recurse externally
Proxmox Cluster Ops
- 5 of 7 hosts fully performance-tuned (tsys1/3/6/7/9)
- Fleet audit refreshed 2026-07-29 (consolidated, storage-corrected)
- Memory goal (≤80% actual) met fleet-wide — highest host is tsys1 at 73%
- Capacity goals codified (80% RAM / ~50% idle CPU + workload model)
- Storage topology corrected:
local-nonprod= S1 disk (not separate); per-host storage.cfg - cnode5 (706) deleted; cnode4 (601) stopped (delete pending)
- tsys6 S1 typo + tsys9 missing S1 — both FIXED by operator (verified: 8/8 NFS stores active on both)
- CPU ~50%-idle goal: fleet idles 0-5% (under-utilized; chase via workloads, not hardware)
- tsys4: blocked on PCIe NIC + RAM install
- tsys5: blocked on 2nd ethernet cable + NVMe install; also single-CPU (CPU2 socket empty)
- tsys2: pending rebuild from Win10 to Proxmox
Kubernetes Control Plane (k3s HA — LIVE)
- 3-node k3s HA control plane deployed: cnode1/2/3 (v1.36.2+k3s1, embedded etcd)
- All traffic over Tailscale IPs — no LAN IPs in node status or certs
- All 3 cnodes tainted
control-plane:NoSchedule(zero user workloads) - 13/13 health checks pass (verify.sh): nodes Ready, etcd quorum, Tailscale IPs, CoreDNS, API server, workload isolation
- Scripts in
k8s/: wipe, install-cp, join-servers, post-setup, verify - Kubeconfig saved to
~/.kube/config.pfv-k8s(gitignored, embedded certs) - Workers (wnodes) not yet joined to this cluster
- Distro decision: k3s chosen for regular R&D cluster. Talos docs
preserved in
k8s/docs/for future ITAR/classified cluster.
PDU Management (powerman on pfv-tsys1 — LIVE)
- Cyclades AlterPath PM10i (10 outlets) managed via powerman over serial
- USB-DB9 adapter (Prolific pl2303) with stable udev symlink
/dev/cyclades-pm10 - powermand listening on
127.0.0.1:10101+ Tailscale100.121.189.98:10101 - All 10 outlets defined as
outlet-1throughoutlet-10 - Validated: outlet 10 cycled off → on (8/8 test checks passed)
- Rename outlets to match physical devices (Friday onsite)
Console Management (ser2net + conman on pfv-tsys4 — LIVE)
- 7 network switch/router consoles managed via ser2net + conman
- USB enumeration problem SOLVED: udev rules pin each adapter by
ID_PATH (physical USB port topology) to stable
/dev/consoles/<name>symlinks that survive reboot regardless of enumeration order - ser2net exposes all 7 consoles on TCP ports (2001-2007) bound to
Tailscale IP only (
100.70.77.93) - conman connects to TCP ports for logging + multiplexing (7 log
files active in
/var/log/conman/) - Both ser2net + conmand enabled via systemd (survive reboot)
- conmand systemd unit created (Debian package doesn't ship one)
- Old
/root/conmap+ manualscreenworkflow replaced
Repo Merge
- KNELServerBuild merged into PFVCluster (history preserved)
- Directory structure reorganized (provisioning/, tests/, perf/, docs/)
- All docs gardened: links fixed, stale refs removed, tailscale.md updated
Known Issues
| Issue | Impact | Status |
|---|---|---|
| 2 of 3 k3s cnodes on tsys4 | tsys4 failure = etcd quorum lost (1 of 3) | Accepted — fundamental constraint with 3 cnodes + 2 NFS servers. Revisit after Friday (local-SSD boot for one cnode). Deferred storage concern. |
| tsys1/5/9 RAM-overcommitted (alloc) | 115%/134%/129% allocation; actual usage 73%/37%/62% — all under 80% goal | Migrate NFS-backed VMs to tsys6/7 (117/171 GB free actual). See AUDIT-2026-07-29 §11 |
| tsys5 is single-CPU | CPU2 socket unpopulated; half the documented CPU capacity | Consider seating a spare LGA771 Xeon (also activates CPU2 DIMM branch) |
| cnode4/5 stale VMs | cnode4 (601) stopped; cnode5 (706) deleted | cnode4 delete pending; cnode5 done ✓ |
| Fleet CPU 0-5% idle | Misses ~50%-idle utilization goal | Consolidate baseline; solar-gate idle PowerEdge; grow via workloads |
| D2 IOPS hotspot | 17 of 26 NFS-backed VMs on one spindle; S1/S4 underused | Phase 2 disk migrations: D2→S2/S3/S4/D5 (see audit §11) |
| Technitium AXFR uses port 53 (occupied by Pi-hole) | Zone transfer via rsync instead of native AXFR | Workaround in place |
| tsys4/5 hardware pending | Perf tuning incomplete on 2 hosts | Friday physical install |
Pending (next session priorities)
Full phased action checklist with current/target inventory is in
proxmox/docs/AUDIT-2026-07-29.md§11. Summary below. SSD/NVMe tiering is deferred to post-Friday.
Phase 0 — Storage config fixes — DONE ✓ (tsys6 S1 typo, tsys9 S1 missing)
Phase 1 — Cleanup:
- Delete cnode4 (601) on tsys6 (stopped, stale)
- cnode5 (706) already deleted ✓
Phase 2 — Disk migrations off D2 (IOPS rebalancing, 6 moves):
- wnode-tsys5 (509): D2→S4 · tsys-awx (600): D2→D5 · hfnoc-uisp (702): D2→S4
- rr-middleware (703): D2→S4 · TCTC (704): D2→S3 · cnode2 (705): D2→S2
Phase 3 — Host + disk migrations (RAM/CPU relief, 6 VMs):
- tsys1→tsys7: librenms(104), pdm(105), tailscale-router(109), kali-tsys(114), workbench(117)
- tsys9→tsys6: tsys-siem(901)
Phase 4 — Grow wnode-tsys9: 4c/4GB → 6c/8GB (after siem leaves tsys9)
Phase 5 — Join wnodes to k3s (after migrations free resources)
Other:
- Friday maintenance: tsys4 (PCIe NIC + RAM), tsys5 (2nd CPU candidate, NVMe, 2nd ethernet)
- PDU: Rename outlets in powerman.conf (Friday onsite)
- k8s deferred: ETL tooling, HPC scheduler, vcluster policy, solar-aware scale-out
Infrastructure Summary
| Component | Details |
|---|---|
| Proxmox hosts | 7 standalone PVE, managed via PDM |
| DNS primary | pfv-netinfra-01 (192.168.3.252) — Technitium + Pi-hole |
| DNS secondary | pfv-netinfra-02 (192.168.3.253) — Technitium + Pi-hole |
| DNS production | tailscale-router (read-only source of truth) |
| NTP | pfv-netinfra-01/02 (redundant, LAN IPs, stratum 2/3) |
| Sandbox VM | sectestbed-sandbox (VMID 6000 on pfv-tsys5) |
| Backup | Proxmox Backup Server (PBS) |
| k8s control plane | 3-node k3s HA (cnode1/2/3), all traffic over Tailscale |
| PDU | Cyclades PM10i via powerman on pfv-tsys1 (port 10101) |
| Console | 7 switch consoles via ser2net+conman on pfv-tsys4 (TCP 2001-2007 on Tailscale) |
| Production | Cloudron VPS, Reston VA (this cluster is R&D only) |