The cross-rack trunk (ch1, 4×1G) between core-sw01 and tor3-stor is
still static mode=on — no failure detection if a cable dies. Adding
command files to convert both switches to LACP during Friday's
maintenance window. Core hash stays layer-2-3 (5448 hardware limit);
stor hash stays layer-2-3-4 (already set).
💘 Generated with Crush
Assisted-by: Crush:glm-5.2
25 lines
841 B
Plaintext
25 lines
841 B
Plaintext
! #369/#394: Convert cross-rack trunk ch1 from static (mode=on) to LACP
|
|
! Switch: pfv-r3-tor-stor (Dell PowerConnect 5324 / "Neyland 24T", rack 3)
|
|
! WHEN: Friday maintenance window — BOTH switches must change together
|
|
! RISK: Brief storage-net outage during transition (seconds)
|
|
!
|
|
! Current: g20-g23 in ch1, mode=on (static, no failure detection)
|
|
! Target: g20-g23 in ch1, LACP active
|
|
!
|
|
! Radlan CLI syntax (different from DNOS on core-sw01)
|
|
! Verify exact keywords on this switch first — 'show running-config'
|
|
! will show the current ch1 config to confirm syntax.
|
|
!
|
|
! IMPORTANT: Run this SIMULTANEOUSLY with core-sw01 change.
|
|
!
|
|
enable
|
|
configure
|
|
interface range ethernet g20-g23
|
|
no channel-group
|
|
channel-group 1 mode active
|
|
exit
|
|
exit
|
|
show interfaces status port-channel 1
|
|
show lacp port-channel 1
|
|
copy running-config startup-config
|