UCS (LDAP/AD) does not need SSD. Corrected placement:
- ucs-01 stays on D2 (tsys4 HDD) -- no change needed
- ucs-02 moves from D5 (tsys4) to S2 (tsys5 HDD) for cross-server
redundancy only, not for speed
D3 SSD (moving to tsys5 Friday) is now freed for workloads that
actually benefit: sectestbed k8s nodes, CI/CD artifact cache, or a
container image registry mirror.
Added storage tier characterization per host (tsys4 = bulk/spinning
only, tsys5 = hybrid fast-tier hub, tsys2/3 = SSD/NVMe only). Added
UCS migration TODO item for today.
💘 Generated with Crush
Assisted-by: Crush:glm-5.2
244 lines
9.4 KiB
Markdown
244 lines
9.4 KiB
Markdown
# TODO.md — Pending User Actions
|
|
|
|
**Date:** 2026-07-27
|
|
**Items needing user input or physical action.**
|
|
|
|
---
|
|
|
|
## 1. tsys2 Windows hardware inventory (run on the Windows host)
|
|
|
|
pfv-tsys2 is currently Windows 10. Before rebuilding it as Proxmox, gather
|
|
hardware data so the architecture plan can account for it.
|
|
|
|
### Option A: PowerShell (recommended — single command, copy-paste output)
|
|
|
|
Open **PowerShell as Administrator** and run:
|
|
|
|
```powershell
|
|
# Full hardware inventory in one shot
|
|
Write-Output "=== COMPUTER ==="
|
|
Get-CimInstance Win32_ComputerSystem | Select-Object Manufacturer, Model, SystemType, TotalPhysicalMemory | Format-List
|
|
|
|
Write-Output "`n=== CPU ==="
|
|
Get-CimInstance Win32_Processor | Select-Object Name, NumberOfCores, NumberOfLogicalProcessors, MaxClockSpeed | Format-List
|
|
|
|
Write-Output "`n=== MEMORY STICKS ==="
|
|
Get-CimInstance Win32_PhysicalMemory | Select-Object Manufacturer, PartNumber, Capacity, Speed, ConfiguredClockSpeed, DeviceLocator, FormFactor | Format-Table -AutoSize
|
|
|
|
Write-Output "`n=== DISKS ==="
|
|
Get-PhysicalDisk | Select-Object FriendlyName, MediaType, BusType, Size, SpindleSpeed | Format-Table -AutoSize
|
|
|
|
Write-Output "`n=== DISK PARTITIONS ==="
|
|
Get-Disk | Select-Object Number, FriendlyName, Size, PartitionStyle, OperationalStatus | Format-Table -AutoSize
|
|
|
|
Write-Output "`n=== NETWORK ADAPTERS ==="
|
|
Get-NetAdapter | Select-Object Name, InterfaceDescription, Status, LinkSpeed, MacAddress | Format-Table -AutoSize
|
|
|
|
Write-Output "`n=== GPU(s) ==="
|
|
Get-CimInstance Win32_VideoController | Select-Object Name, AdapterRAM, DriverVersion, VideoProcessor | Format-List
|
|
|
|
Write-Output "`n=== PCIe SLOTS ==="
|
|
Get-CimInstance Win32_SystemSlot | Select-Object SlotDesignation, CurrentUsage, Status | Format-Table -AutoSize
|
|
|
|
Write-Output "`n=== USB DEVICES (storage + network only) ==="
|
|
Get-PnpDevice -PresentOnly | Where-Object { $_.Class -in @('DiskDrive','Net','USB') } | Select-Object Class, FriendlyName, Status | Format-Table -AutoSize
|
|
```
|
|
|
|
Copy the full output into a file (e.g., `tsys2-hardware.txt`) or paste it
|
|
directly into the chat.
|
|
|
|
### Option B: Command Prompt (cmd.exe) fallbacks
|
|
|
|
If PowerShell is unavailable for some reason, these cmd commands give a
|
|
subset:
|
|
|
|
```cmd
|
|
:: Computer model and serial
|
|
wmic computersystem get manufacturer,model
|
|
wmic bios get serialnumber
|
|
|
|
:: CPU
|
|
wmic cpu get name,numberofcores,numberoflogicalprocessors,maxclockspeed
|
|
|
|
:: RAM (total)
|
|
wmic computersystem get totalphysicalmemory
|
|
|
|
:: RAM sticks (per-slot detail)
|
|
wmic memorychip get manufacturer,capacity,speed,partnumber,devicelocator
|
|
|
|
:: Disks
|
|
wmic diskdrive get model,size,interfacetype,mediatype
|
|
|
|
:: Network adapters
|
|
wmic nic where netenabled=true get name,speed,macaddress
|
|
|
|
:: GPU
|
|
wmic path win32_videocontroller get name,adapterram,driverversion
|
|
```
|
|
|
|
### What I'm looking for
|
|
|
|
- **Disk inventory**: Are there any SSDs/NVMe available locally? (Determines
|
|
whether wnode-tsys2 can use local storage like the other wnodes.)
|
|
- **Network adapters**: How many onboard NICs? Model? (Determines whether
|
|
tsys2 needs a USB dongle for storage network like tsys4/9, or has a real
|
|
onboard NIC available.)
|
|
- **RAM layout**: Is all 32 GB in 1 stick, 2 sticks, or 4 sticks? (Affects
|
|
memory bandwidth for HPC workloads — dual-channel matters.)
|
|
- **GPU detail**: Confirm the Quadro M1200 model and VRAM for passthrough
|
|
planning.
|
|
- **PCIe slots**: Is there a free PCIe slot for adding a NIC or HBA?
|
|
- **Service tag confirmation**: `GH1XZG2` (already on file from spreadsheet).
|
|
|
|
### STATUS: Collected 2026-07-27
|
|
|
|
**Disk inventory — RESOLVED:**
|
|
- Disk 0: Samsung SSD 960 PRO **512 GB NVMe** (best local storage in fleet)
|
|
- Disk 1: Samsung SSD 850 EVO **1 TB SATA SSD**
|
|
- Both SSDs, no spinning rust. 1.5 TB total local SSD.
|
|
|
|
**Network adapters — RESOLVED (concerning):**
|
|
- StorageNetwork: **ASIX USB to Gigabit Ethernet** (dongle, D4-81-D7-3E-0D-5E)
|
|
- Ethernet: **Realtek USB GbE Family Controller** (also USB, 18-FD-CB-00-D2-CA)
|
|
- Wi-Fi: Intel 8265 (disconnected)
|
|
- **Both wired NICs are USB-attached.** Same anti-pattern as tsys4/9.
|
|
Unavoidable on this laptop form factor — no onboard PCIe NIC available.
|
|
|
|
**GPU — RESOLVED:**
|
|
- Intel HD Graphics 630 (integrated, 1 GB)
|
|
- NVIDIA Quadro M1200 (4 GB, confirmed for passthrough)
|
|
|
|
**PCIe slots — RESOLVED:**
|
|
- Slots 3/6/7/8 report "Available" but these are laptop M.2/WWAN slots, not
|
|
user-accessible full PCIe. **Cannot add a PCIe NIC.** NVMe slot occupied
|
|
by 960 PRO.
|
|
|
|
**RAM — PARTIAL:**
|
|
- Total 32 GB confirmed (34,097,573,888 bytes).
|
|
- Per-stick detail failed to run (PowerShell line-break split
|
|
`Format-T` + `able`). Re-run the command below if bandwidth planning
|
|
needs stick-level detail:
|
|
```powershell
|
|
Get-CimInstance Win32_PhysicalMemory | Select-Object Manufacturer, PartNumber, Capacity, Speed, ConfiguredClockSpeed, DeviceLocator, FormFactor | Format-Table -AutoSize
|
|
```
|
|
|
|
**Service tag — CONFIRMED:** `GH1XZG2` (Precision 5520).
|
|
|
|
---
|
|
|
|
## 2. Friday maintenance window (physical hardware)
|
|
|
|
### tsys4 — install PCIe NIC + add RAM
|
|
|
|
1. Power down tsys4 (graceful shutdown via Proxmox UI or `shutdown -h now`).
|
|
2. Install the **PCIe NIC** (Intel i350-T2 or similar 1 GbE dual-port).
|
|
3. Add **RAM**: 16 GB → 64 GB DDR3 ECC.
|
|
4. Power on, then update `/etc/network/interfaces` to replace
|
|
`enx8cae4ccda926` (USB dongle) with the new PCIe NIC device name.
|
|
5. Reboot to activate new NIC and NFS nconnect.
|
|
6. Run `validate-fixes.sh pfv-tsys4` to confirm.
|
|
|
|
### tsys5 — plug storage cable + install NVMe + relocate D3 SSD
|
|
|
|
1. Plug the **second ethernet cable** into tsys5's dedicated storage NIC.
|
|
2. Verify bond0 recovery: `cat /proc/net/bonding/bond0` — look for
|
|
"Number of ports: 2" and a real partner MAC (not all zeros).
|
|
3. Apply bond hash fix (same as tsys6/7):
|
|
```bash
|
|
echo "layer3+4" > /sys/class/net/bond0/bonding/xmit_hash_policy
|
|
```
|
|
4. **Relocate D3 SSD** from tsys4 USB to tsys5 SAS port:
|
|
- Power down tsys4
|
|
- Remove the SK hynix SC300 SSD from its USB enclosure on tsys4
|
|
- Install it on a free SAS port on tsys5 (5 ports free on LSI SAS1068E)
|
|
- On tsys5: mount as `/mnt/pfv-tsys5/D3`, add to `/etc/exports`
|
|
- Update `/etc/pve/storage.cfg` cluster-wide: repoint D3 `server` from
|
|
`pfv-tsys4-nfs-stor` to `pfv-tsys5-nfs-stor`, update `export` path
|
|
- Copy any existing D3 data from tsys4 first (currently ~2 MB, essentially
|
|
empty, so minimal migration)
|
|
5. Install the **PCI NVMe drive** (uses a PCI slot, not a SATA/SAS port).
|
|
6. Format NVMe as local directory storage (see TODO section 3 below).
|
|
7. Reboot tsys5 to activate NFS nconnect.
|
|
8. Run `validate-fixes.sh pfv-tsys5` to confirm.
|
|
|
|
---
|
|
|
|
## 3. tsys5 NVMe format/mount decision (after Friday install)
|
|
|
|
**Recommendation: local-only, not NFS-exported.** Format as Proxmox directory
|
|
storage so it shows up as a VM image target in the Proxmox UI.
|
|
|
|
After the NVMe is physically installed and visible in Proxmox:
|
|
|
|
1. Identify the device: `lsblk` or `ls /dev/nvme*`
|
|
2. Format and add to Proxmox:
|
|
```bash
|
|
# Option A: LVM-thin (thin provisioning, snapshots)
|
|
pvcreate /dev/nvme0n1
|
|
vgcreate nvme-pool /dev/nvme0n1
|
|
lvcreate -l 100%FREE -T nvme-pool/data
|
|
# Then in Proxmox UI: Datacenter > Storage > Add > LVM-Thin
|
|
# ID: nvme-local
|
|
# Volume Group: nvme-pool
|
|
# Thin Pool: data
|
|
# Content: Disk image, Container template
|
|
|
|
# Option B: Directory (simpler, no thin provisioning)
|
|
mkfs.ext4 /dev/nvme0n1
|
|
mkdir -p /mnt/nvme
|
|
mount /dev/nvme0n1 /mnt/nvme
|
|
# Add to /etc/fstab for persistence
|
|
# Then in Proxmox UI: Datacenter > Storage > Add > Directory
|
|
# ID: nvme-local
|
|
# Directory: /mnt/nvme
|
|
# Content: Disk image, Container template
|
|
```
|
|
|
|
3. Use for wnode-tsys5 boot disk (highest impact) and sectestbed VM scratch.
|
|
|
|
---
|
|
|
|
## 4. Post-hardware validation (run after Friday work)
|
|
|
|
1. Re-run iperf matrix: `./iperf-full-matrix.sh`
|
|
2. Validate tsys4 and tsys5: `./validate-fixes.sh pfv-tsys4 && ./validate-fixes.sh pfv-tsys5`
|
|
3. Update PROJECT.md with post-hardware iperf numbers.
|
|
|
|
---
|
|
|
|
## 5. UCS storage migration to spinning disk (do today)
|
|
|
|
UCS (Univention Corporate Server / open-source AD) does not need SSD. Both
|
|
UCS VMs should stay on spinning disk (HDD) and be split across storage
|
|
servers for redundancy.
|
|
|
|
| VM | Current | Target | Action |
|
|
|----|---------|--------|--------|
|
|
| ucs-01 (108) | D2 (tsys4 HDD) | **D2 (tsys4 HDD) -- no change** | Already correct |
|
|
| ucs-02 (902) | D5 (tsys4 HDD) | **S2 (tsys5 HDD)** | Move for cross-server redundancy |
|
|
|
|
**To migrate ucs-02 to S2:**
|
|
1. Shut down VM 902 on tsys9
|
|
2. Copy disk: `cp /mnt/pve/D5/902/vm-902-disk-0.qcow2 /mnt/pve/S2/902/`
|
|
3. Update VM 902 config: change `scsi0` from `D5:902/...` to `S2:902/...`
|
|
4. Start VM 902, verify it boots and LDAP/AD services are healthy
|
|
5. Remove old disk from D5
|
|
|
|
Note: both VMs are currently on tsys4 HDD, which is fine for UCS. Only
|
|
ucs-02 needs to move -- it should be on a different storage server than
|
|
ucs-01 so a tsys4 failure doesn't take down both halves of the AD pair.
|
|
|
|
---
|
|
|
|
## 6. Open questions for next session
|
|
|
|
- Are the hosts a Proxmox cluster (`pvecm status`) or standalone installs?
|
|
Determines whether live migration is available.
|
|
- What k8s distribution is in use? (k3s, kubeadm, RKE2?)
|
|
- Container runtime? (containerd, cri-o?)
|
|
- Is there a local container image registry mirror?
|
|
- What specific ETL tools? (GDAL, PostGIS, xarray, Dask?)
|
|
- HPC job scheduler? (plain k8s Jobs, Argo Workflows, Volcano?)
|
|
- What uses tsys5's SDR + parallel port before planning tsys5 role changes?
|
|
- tsys3 thermal state (laptop in rack for years) — check `sensors`.
|