Files
mrcharles 019ab468bf feat: relocate D3 SSD from tsys4 USB to tsys5 SAS on Friday
Deep-dive on tsys4/5 storage controllers revealed:
- tsys4: 4-port SATA, all occupied; D3 SSD is USB 2.0
- tsys5: LSI SAS1068E (8-port, 5 free) + ICH10 SATA (2 free) + USB 3.0

Decision: move D3 (SK hynix SSD) to a tsys5 SAS port. Eliminates USB
bottleneck and consolidates all fast storage on tsys5: NVMe (local) +
D3 SSD + T5-SSD + 4 HDD exports.

Updated storage architecture, speed tiers, critical VM placement,
failure survival matrix, StorageClass design, and Friday plan.

💘 Generated with Crush

Assisted-by: Crush:glm-5.2
2026-07-27 11:50:16 -05:00

475 lines
20 KiB
Markdown

# K8S.md -- Kubernetes Architecture Deep-Dive
**Date:** 2026-07-27
**Purpose:** Detailed kubernetes architecture plan for the pfv-k8s cluster.
Companion to `PROJECT.md` (which has the fleet-wide assessment).
**Status:** For discussion in a future session. No changes made.
---
## Table of Contents
1. [Workload Profile](#1-workload-profile)
2. [Current State](#2-current-state)
3. [Target Architecture](#3-target-architecture)
4. [Control Plane (Cnodes)](#4-control-plane-cnodes)
5. [Worker Nodes (Wnodes)](#5-worker-nodes-wnodes)
6. [Storage Class Design](#6-storage-class-design)
7. [ETL/HPC Considerations](#7-etlhpc-considerations)
8. [Migration Plan](#8-migration-plan)
---
## 1. Workload Profile
This cluster runs **R&D and RackRental (containerlab) workloads** via
Kubernetes. Production (Gitea, RustFS, Redmine, websites) lives on a VPS in
Reston, VA running Cloudron.
**Workload types expected:**
| Type | Description | Storage need | RAM need | Examples |
|------|------------|-------------|----------|---------|
| **ETL (weather/GIS)** | Batch processing of large geospatial datasets. Sequential reads, transform, sequential writes. | High capacity (100s of GB), moderate IOPS | Medium (8-32 GB per job) | GRIB/NetCDF processing, raster reprojection |
| **HPC (hardware startup)** | Compute-intensive simulations, firmware build pipelines, hardware-in-the-loop testing. | Low capacity, moderate IOPS | High (32-128 GB per job) | RTL simulation, PCB thermal analysis |
| **RackRental (containerlab)** | Rapid deployment/teardown of network lab topologies. Many containers, short-lived. | Low capacity, high IOPS (container image pulls) | Low-Medium (4-16 GB) | Network topology testing, protocol validation |
**Key storage insight:** ETL workloads need bulk capacity (NFS-HDD is fine --
sequential I/O). HPC and containerlab need low-latency random I/O (local
SSD/NVMe is essential). The tiered StorageClass design (section 6) serves both.
---
## 2. Current State
### 2.1 pfv-k8s nodes and their storage
| Node | Type | Host | Storage | Disk type | Status |
|------|------|------|---------|-----------|--------|
| cnode1 (107) | control | tsys1 | D5 (tsys4) | NFS-HDD | running |
| cnode2 (603) | control | tsys6 | D2 (tsys4) | NFS-HDD | running |
| cnode3 (106) | control | tsys1 | D2 (tsys4) | NFS-HDD | running |
| cnode4 (601) | control | tsys6 | D2 (tsys4) | NFS-HDD | running |
| cnode5 (602) | control | tsys6 | D5 (tsys4) | NFS-HDD | running |
| wnode-tsys3 (313) | worker | tsys3 | D5 (tsys4) | NFS-HDD | running |
| wnode-tsys5 (509) | worker | tsys5 | D2 (tsys4) | NFS-HDD | running |
| wnode-tsys6 (100) | worker | tsys6 | D5 (tsys4) | NFS-HDD | **STOPPED** |
| wnode-tsys7 (701) | worker | tsys7 | D5 (tsys4) | NFS-HDD | running |
| wnode-tsys9 (905) | worker | tsys9 | S3 (tsys5) | NFS-HDD | running |
### 2.2 Problems
1. **100% of cnodes on tsys4 NFS.** D2 disk failure loses 3 of 5 cnodes =
etcd quorum lost.
2. **90% of all k8s nodes on tsys4 NFS.** tsys4 failure kills the cluster.
3. **Zero nodes use SSD or NVMe.** All on NFS-over-HDD.
4. **Zero nodes use local-lvm.** tsys3/6/7/9 all have empty local storage
(349 GB / 1.7 TB / 1.7 TB / 136 GB SSD respectively).
5. **wnode-tsys6 is stopped.** Reduces cluster capacity.
6. **3 cnodes on tsys6** -- should be on lighter hosts to free tsys6 for workers.
---
## 3. Target Architecture
### 3.1 Design principles
1. **Cnodes on lightweight hosts** (tsys1, tsys9, tsys3) -- frees tsys6/7 for
heavy workers.
2. **Cnode storage split across tsys4 and tsys5** -- etcd survives either
storage server failing.
3. **Wnode boot disks on local storage** -- eliminates NFS latency for
container runtime and kubelet.
4. **Wnode data disks on NFS-HDD** -- bulk capacity for ETL/weather/GIS.
5. **tsys5 NVMe dedicated to wnode-tsys5** -- fastest tier for HPC jobs.
6. **One wnode per hypervisor host** -- maximize total cluster capacity.
### 3.2 Target node-host-storage matrix
| Node | Type | Host | Boot disk | Data disk | Disk type |
|------|------|------|-----------|-----------|-----------|
| cnode1 | control | tsys1 | D5 (tsys4) | -- | NFS-HDD |
| cnode2 | control | tsys9 | D2 (tsys4) | -- | NFS-HDD |
| cnode3 | control | tsys1 | S2 (tsys5) | -- | NFS-HDD |
| cnode4 | control | tsys9 | D5 (tsys4) | -- | NFS-HDD |
| cnode5 | control | tsys3 | S3 (tsys5) | -- | NFS-HDD |
| wnode-tsys1 | worker | tsys1 | D5 (tsys4) | -- | NFS-HDD (small) |
| wnode-tsys2 | worker | tsys2 | **NVMe (960 PRO 512GB)** | **SATA SSD (850 EVO 1TB)** | **NVMe + SSD -- no NFS needed** |
| wnode-tsys3 | worker | tsys3 | **local-lvm (NVMe PM961)** | S3 (NFS) | **LOCAL-NVMe** |
| wnode-tsys5 | worker | tsys5 | **NVMe (local, Friday)** | local-nonprod (HDD) | **NVMe** |
| wnode-tsys6 | worker | tsys6 | D2 (tsys4 NFS) | -- | NFS-HDD (local-lvm is USB 2.0 -- do not use) |
| wnode-tsys7 | worker | tsys7 | D5 (tsys4 NFS) | -- | NFS-HDD (local-lvm is USB 2.0 -- do not use) |
| wnode-tsys9 | worker | tsys9 | **local-lvm (SSD)** | S2 (NFS) | **LOCAL-SSD** |
### 3.3 Storage server distribution after changes
| Storage server | cnodes | wnodes (boot) | wnodes (data) |
|---------------|--------|---------------|---------------|
| tsys4 (D2) | cnode2 | wnode-tsys6 | wnode-tsys7 |
| tsys4 (D5) | cnode1, cnode4 | wnode-tsys1 | -- |
| tsys5 (S2) | cnode3 | wnode-tsys9 | -- |
| tsys5 (S3) | cnode5 | -- | wnode-tsys3 |
**Note:** wnode-tsys2 needs no NFS (1.5 TB local SSD). wnode-tsys6/7 stay on
NFS by design -- their local-lvm is USB 2.0 portable HDD (~30 MB/s), slower
than NFS-HDD, and the user has chosen not to install internal drives.
**No single disk or server is a quorum-losing failure point.**
---
## 4. Control Plane (Cnodes)
### 4.1 Cnode sizing
Each cnode: 4 cores, 4 GB RAM, 32 GB disk. This is sufficient for etcd +
kubernetes control plane components (API server, scheduler, controller-manager).
### 4.2 Cnode host placement rationale
| Host | cnodes | RAM for cnodes | Total host RAM | Remaining for other VMs |
|------|--------|---------------|---------------|------------------------|
| tsys1 | 2 (cnode1, cnode3) | 8 GB | 32 GB | ~24 GB (but 11 infra VMs consume most) |
| tsys9 | 2 (cnode2, cnode4) | 8 GB | 24 GB | ~16 GB (4 infra VMs + 1 wnode) |
| tsys3 | 1 (cnode5) | 4 GB | 32 GB | ~28 GB (1 wnode at 20 GB = 8 GB headroom) |
**tsys6 and tsys7 have ZERO cnodes** -- fully dedicated to heavy worker nodes.
### 4.3 Cnode storage placement rationale
The 5 cnodes are split 3-on-tsys4 / 2-on-tsys5:
| Disk | cnodes | Rationale |
|------|--------|-----------|
| D5 (tsys4 HDD) | cnode1, cnode4 | Spread load across 2 disks on tsys4 |
| D2 (tsys4 HDD) | cnode2 | Only 1 cnode on D2 (was 3 -- reduces blast radius) |
| S2 (tsys5 HDD) | cnode3 | tsys5 storage for quorum diversity |
| S3 (tsys5 HDD) | cnode5 | tsys5 storage, different disk than S2 |
**If D2 fails:** cnode2 dies. 4 of 5 survive. Quorum OK.
**If D5 fails:** cnode1 + cnode4 die. 3 of 5 survive. Quorum OK.
**If tsys4 fails:** cnode1, cnode2, cnode4 die. cnode3 + cnode5 survive on
tsys5. **Only 2 of 5 -- QUORUM LOST.**
Wait -- that is a problem. If tsys4 goes completely offline, we lose 3
cnodes and only have 2 on tsys5. That loses quorum (need 3).
**Revision needed:** Move 1 more cnode to tsys5 storage. Target: 2 on tsys4,
3 on tsys5. But that means tsys5 failure (3 cnodes die) leaves only 2 on
tsys4. Same problem inverted.
The fundamental issue: with 5 cnodes and 2 storage servers, the best split is
3/2. The server holding 3 cnodes is a quorum-loss risk if it fails. The server
holding 2 cnodes is safe (3 survive).
**Proper solution: 3 cnodes on the "less likely to fail" server, 2 on the
other.** After Friday's hardware work:
- tsys4 will have a new PCIe NIC + 64 GB RAM -- more reliable
- tsys5 will have bond0 fixed + NVMe -- more reliable
Either way, 3/2 split means one server failure could lose quorum. **To truly
solve this, use a 3rd storage target.** Options:
- Use tsys9 local SSD for 1 cnode (breaks the 2-server model, adds a 3rd
independent failure domain)
- Use local-lvm on the cnode's own host (etcd data is local to the VM's host,
no NFS dependency at all)
**Best option: put cnode boot disks on local-lvm where available.** This
eliminates NFS entirely for the control plane. Each cnode's etcd data lives on
its own host's local disk -- no shared dependency.
| cnode | Host | **Recommended storage** | Type |
|-------|------|------------------------|------|
| cnode1 | tsys1 | **local-lvm** (if space) or D5 (tsys4) | LOCAL-HDD or NFS-HDD |
| cnode2 | tsys9 | **local-lvm (SSD)** | **LOCAL-SSD** |
| cnode3 | tsys1 | **S2 (tsys5)** | NFS-HDD |
| cnode4 | tsys9 | **local-lvm (SSD)** | **LOCAL-SSD** |
| cnode5 | tsys3 | **local-lvm** | LOCAL-HDD |
With this layout, a tsys4 failure takes down 0 cnodes. A tsys5 failure takes
down 1 (cnode3). A host failure takes down at most 2 cnodes. Quorum always
survives.
**This is the recommended approach.** Local storage for cnodes wherever
possible. NFS only as fallback.
### 4.4 etcd performance on local vs NFS
| Storage | Typical fsync latency | etcd commit latency | Impact |
|---------|----------------------|--------------------|--------|
| NFS-HDD (via USB dongle on tsys4) | 5-15 ms | 10-30 ms | Slow API responses, sluggish pod scheduling |
| NFS-HDD (via PCIe NIC, post-Friday) | 2-8 ms | 5-15 ms | Better but still network-bound |
| Local HDD (tsys1/3/6/7 local-lvm) | 1-5 ms | 3-10 ms | No network hop, moderate improvement |
| Local SSD (tsys9 PNY CS900) | 0.1-0.5 ms | 0.5-2 ms | **10-30x faster than NFS-HDD** |
| NVMe (tsys5, Friday) | 0.02-0.1 ms | 0.1-0.5 ms | **100x faster than NFS-HDD** |
etcd is the heartbeat of the kubernetes control plane. Every API call, every
pod schedule, every controller reconciliation involves an etcd write. Cutting
etcd commit latency from 15 ms to 1 ms makes the entire cluster feel 15x more
responsive. **This is the single highest-impact change for k8s performance.**
---
## 5. Worker Nodes (Wnodes)
### 5.1 One wnode per hypervisor host
| Host | wnode | Boot disk | Data disk | Total RAM | wnode RAM | Role |
|------|-------|-----------|-----------|-----------|-----------|------|
| tsys1 | wnode-tsys1 | D5 (tsys4 NFS) | -- | 32 GB | 4-8 GB | Small worker, infra co-tenant |
| tsys2 | wnode-tsys2 | **NVMe (960 PRO 512GB)** | **SATA SSD (850 EVO 1TB)** | 32 GB | 16-24 GB | **Best storage of any worker -- 1.5TB local SSD, no NFS needed** |
| tsys3 | wnode-tsys3 | **local-lvm (349 GB)** | S3 (NFS) | 32 GB | 20 GB | General worker |
| tsys5 | wnode-tsys5 | **NVMe (local)** | local-nonprod (HDD) | 96 GB | 32-64 GB | **HPC/ETL powerhouse** |
| tsys6 | wnode-tsys6 | D2 (tsys4 NFS) | -- | 128 GB | 64-96 GB | **Heavy worker, max RAM.** local-lvm is USB 2.0 -- stays on NFS |
| tsys7 | wnode-tsys7 | D5 (tsys4 NFS) | -- | 192 GB | 96-128 GB | **Heavy worker, max RAM.** local-lvm is USB 2.0 -- stays on NFS |
| tsys9 | wnode-tsys9 | **local-lvm SSD (136 GB)** | S2 (NFS) | 24 GB | 4-8 GB | Small worker, SSD boot |
### 5.2 Why boot disks on local-lvm
Current: all wnodes boot from NFS. Every container image pull, every kubelet
log write, every ephemeral volume traverses the NFS network path.
With local-lvm boot disks:
- **Container image pulls** write to local disk (100-150 MB/s HDD, no network
hop) instead of NFS-HDD (80-120 MB/s with network latency)
- **kubelet logs** stay local (no NFS writes for log rotation)
- **ephemeral storage** (emptyDir volumes) uses local disk by default
- **NFS server failure does not kill the wnode** -- the VM stays running, only
the data disk (if mounted) goes away
### 5.3 Wnode sizing guidance
| Host | Recommended wnode config | Rationale |
|------|------------------------|-----------|
| tsys7 (192 GB) | 8-12 cores, 96-128 GB RAM, NFS boot | Largest host -- run the heaviest ETL/HPC jobs here. local-lvm is USB 2.0 |
| tsys6 (128 GB) | 8 cores, 64-96 GB RAM, NFS boot | Second-largest -- parallel heavy jobs. local-lvm is USB 2.0 |
| tsys5 (96 GB + NVMe) | 4 cores, 32-64 GB RAM, NVMe boot + HDD data | NVMe makes this fastest for I/O-bound HPC |
| tsys3 (32 GB) | 4 cores, 20 GB RAM, local-lvm boot | General-purpose worker |
| tsys2 (32 GB, NVMe+SSD, incoming) | 4 cores, 16-24 GB RAM, **NVMe boot + SSD data** | **Fastest storage worker** -- HPC with I/O bounds |
| tsys1 (32 GB) | 2 cores, 4-8 GB RAM | Small worker, don't starve infra VMs |
| tsys9 (24 GB) | 2-4 cores, 4-8 GB RAM | Small worker, SSD boot is the advantage |
### 5.4 Tainting and labeling strategy
Label wnodes by capability so the k8s scheduler can target them:
```yaml
# Heavy RAM hosts (ETL/HPC)
wnode-tsys6: workload=heavy, ram=128g
wnode-tsys7: workload=heavy, ram=192g
# NVMe host (I/O-intensive HPC)
wnode-tsys5: workload=hpc, storage=nvme
# SSD boot host (low-latency)
wnode-tsys9: workload=light, storage=ssd
# General workers
wnode-tsys3: workload=general
wnode-tsys2: workload=storage-fast, storage=nvme
wnode-tsys1: workload=light
```
Then use nodeSelector or nodeAffinity in job specs:
```yaml
# Weather/GIS ETL job -- needs lots of RAM
spec:
nodeSelector:
workload: heavy
# Firmware build -- needs fast storage
spec:
nodeSelector:
storage: nvme
```
---
## 6. Storage Class Design
### 6.1 Proposed StorageClasses
| StorageClass | Provisioner | Where | Speed | Use case |
|-------------|------------|-------|-------|----------|
| `local-fast` | local-path (k8s) | wnode local-lvm / NVMe | 100-3500 MB/s | Container runtime, scratch, databases |
| `nfs-hdd` | nfs-subdir-external-provisioner | tsys4 D2/D5, tsys5 S1-S4 | 80-120 MB/s | Bulk data, weather/GIS datasets |
| `nfs-ssd` | nfs-subdir-external-provisioner | tsys4 D3, tsys5 T5-SSD | 200-400 MB/s | Latency-sensitive persistent data |
### 6.2 How this maps to wnode disk topology
Each wnode has:
- **Disk 1 (boot/OS):** local-lvm or NVMe. Contains the OS, kubelet, container
runtime. k8s `local-fast` StorageClass provisioner points here.
- **Disk 2 (bulk data, optional):** NFS mount. Mounted inside the VM as a
second block device or filesystem. k8s `nfs-hdd` provisioner points here.
Inside k8s, pods request storage via PVC:
```yaml
# ETL job: needs bulk storage for weather data
apiVersion: v1
kind: PersistentVolumeClaim
spec:
storageClassName: nfs-hdd
accessModes: [ReadWriteMany] # NFS allows RWX
resources:
requests:
storage: 500Gi
# HPC job: needs fast scratch
spec:
storageClassName: local-fast
accessModes: [ReadWriteOnce]
resources:
requests:
storage: 50Gi
```
### 6.3 NFS-SSD tier (D3 and T5-SSD -- both on tsys5 after Friday)
The SSD NFS exports are a middle tier. **Both consolidated on tsys5** after
the Friday D3 relocation:
- **D3 (tsys5 SAS, 445 GB free):** CI/CD artifacts, container image cache,
UCS/LDAP. Currently 99% empty. Fastest NFS tier after the move off USB.
- **T5-SSD (tsys5 SAS, 140 GB free):** SIEM databases, monitoring data.
Currently 35% used by ultix-streaming.
**tsys5 is the fast-tier hub:** NVMe (local) + D3 SSD + T5-SSD all on one host.
This simplifies the StorageClass design -- latency-sensitive PVCs target
tsys5 exports, bulk PVCs target either server.
### 6.4 NFS data distribution across storage servers
To avoid re-creating the "everything on tsys4" problem, distribute NFS data
disks across both servers:
| wnode | Boot (local) | Bulk data (NFS) | NFS server |
|-------|-------------|-----------------|------------|
| wnode-tsys3 | local-lvm | S3 | tsys5 |
| wnode-tsys5 | NVMe | local-nonprod | local (no NFS) |
| wnode-tsys6 | D2 (tsys4 NFS) | -- | tsys4 |
| wnode-tsys7 | D5 (tsys4 NFS) | -- | tsys4 |
| wnode-tsys9 | local-lvm (SSD) | S2 | tsys5 |
This balances: 2 wnodes using tsys4 for bulk data, 2 using tsys5.
---
## 7. ETL/HPC Considerations
### 7.1 Weather/GIS ETL pipeline
Typical flow: download GRIB/NetCDF files -> process (reproject, aggregate) ->
store results.
| Stage | Storage class | Why |
|-------|-------------|-----|
| Download raw data | `nfs-hdd` | Large sequential writes. NFS-HDD handles this well. |
| Processing scratch | `local-fast` | Random access during transform. Local disk avoids NFS latency. |
| Store results | `nfs-hdd` | Large sequential writes. Persistent. |
**Recommendation:** Deploy a `local-fast` PV mount as `/scratch` on every
wnode. ETL jobs use `/scratch` for intermediate processing and write final
output to the NFS-mounted `/data`.
### 7.2 HPC workloads (hardware startup)
Use cases: RTL simulation, PCB thermal analysis, firmware build pipelines.
| Workload | Best wnode | Why |
|----------|-----------|-----|
| RTL simulation (CPU-bound, high RAM) | tsys7 (192 GB) | Most RAM, most cores (24t) |
| Firmware builds (I/O-bound, moderate RAM) | tsys5 (NVMe) | Fastest storage for compile I/O |
| Hardware-in-the-loop (latency-sensitive) | tsys9 (local SSD) | Lowest latency storage |
| Parallel batch jobs | tsys6 + tsys7 | Distribute across both heavy hosts |
### 7.3 RackRental/containerlab
Rapid container deployment. Key need: fast container image pulls.
This is where **local-lvm boot disks** shine. Currently, every container image
pull writes through NFS to a spinning disk -- slow. With local-lvm, images
cache on local disk (even HDD is 2-3x faster than NFS-HDD for random I/O).
On tsys9 (SSD) and tsys5 (NVMe), image pulls are near-instant.
### 7.4 Data locality for ETL
For weather/GIS data that is read repeatedly (e.g., climate reanalysis), cache
it on local-lvm of the heavy hosts:
```
tsys3 local-lvm (NVMe 349 GB): /data/cache/weather/ -- fastest cache tier
tsys5 NVMe (local): /data/cache/gis/ -- fastest cache tier
```
**Note:** tsys6/7 local-lvm is USB 2.0 portable HDD (~30 MB/s) -- cannot
be used for caching. Pre-populate weather/GIS data on D2/D5 (NFS) instead.
This avoids re-reading the same data from the same NFS export on every job
if the data is already cached in the page cache.
---
## 8. Migration Plan
### 8.1 Phase 1: Friday (after hardware work)
After tsys5 cable + NVMe and tsys4 NIC + RAM:
1. **Format tsys5 NVMe** as local directory storage (e.g., `nvme-local`)
2. **Restart wnode-tsys6** (VM 100). Keep on NFS (D5). local-lvm is USB 2.0 --
do not use for VM storage. Recreate on D2 or D5 NFS.
3. **Move wnode-tsys9** (VM 905) disk from S3 (NFS) to local-lvm (SSD).
### 8.2 Phase 2: Cnode rebalance (maintenance window)
These changes require creating new VMs on target hosts and migrating disks.
Plan for a maintenance window with the k8s cluster briefly down.
1. Create cnode2 on tsys9 (local-lvm SSD if possible, or D2 NFS).
2. Create cnode4 on tsys9 (D5 NFS or local-lvm SSD).
3. Create cnode5 on tsys3 (S3 NFS or local-lvm).
4. Move cnode3 disk from D2 to S2 (tsys4 to tsys5).
5. Join new cnodes to etcd cluster, drain old cnode2/4/5, remove.
### 8.3 Phase 3: Wnode local storage migration (maintenance window)
1. Recreate wnode-tsys3 with boot disk on local-lvm (349 GB).
2. wnode-tsys6 stays on NFS (local-lvm is USB 2.0 HDD -- not suitable).
3. wnode-tsys7 stays on NFS (same reason).
4. Recreate wnode-tsys5 with boot disk on NVMe.
5. Add data disks (NFS) as second SCSI devices where applicable.
### 8.4 Phase 4: tsys2 integration (when rebuilt)
1. Install Proxmox on tsys2.
2. Run `scripts/check.sh` to inventory.
3. Run `scripts/apply-tunings.sh --apply`.
4. Create wnode-tsys2 with **boot disk on NVMe (960 PRO)** and **data disk on SATA SSD (850 EVO)**. No NFS needed -- 1.5 TB local SSD is the most local storage of any worker.
5. Join to k8s cluster.
### 8.5 Phase 5: Critical VM relocation
1. Move netinfra-02 (VM 904) from D2 to S3.
2. Move ucs-01 (VM 108) from D2 to D3 (SSD).
3. Move ucs-02 (VM 902) from D5 to tsys9 local-lvm (SSD).
---
## Open questions for next session
1. **Are the hosts a Proxmox cluster (pvecm) or standalone?** This determines
whether live migration is available (huge simplification) or we need manual
disk migration. Check `pvecm status` on each host.
2. **What k8s distribution is in use?** (k3s, kubeadm, RKE2?) This affects how
nodes are joined/drain and how StorageClasses are configured.
3. **Container runtime?** (containerd, cri-o?) Affects local storage layout.
4. **Is there a container image registry mirror in the cluster?** Or do all
pulls go to Docker Hub / external? A local registry on D3 SSD would speed
up all pulls.
5. **What specific ETL tools?** (GDAL, PostGIS, xarray, Dask?) This affects
whether jobs need shared (RWX) or exclusive (RWO) storage.
6. **HPC job scheduler?** (plain k8s Jobs, Argo Workflows, Volcano?) Affects
how we label and taint nodes.