Deep-dive on tsys4/5 storage controllers revealed:
- tsys4: 4-port SATA, all occupied; D3 SSD is USB 2.0
- tsys5: LSI SAS1068E (8-port, 5 free) + ICH10 SATA (2 free) + USB 3.0
Decision: move D3 (SK hynix SSD) to a tsys5 SAS port. Eliminates USB
bottleneck and consolidates all fast storage on tsys5: NVMe (local) +
D3 SSD + T5-SSD + 4 HDD exports.
Updated storage architecture, speed tiers, critical VM placement,
failure survival matrix, StorageClass design, and Friday plan.
💘 Generated with Crush
Assisted-by: Crush:glm-5.2
7.0 KiB
AGENTS.md — Proxmox Performance Optimization Project
Read this first. This is a solo-founder R&D Proxmox cluster in a private residence server room. Shoestring budget. Redundancy is NOT a concern — this is for batch jobs. Backups DO matter (PBS in use). Production lives elsewhere.
Four .md files exist:
AGENTS.md(this file) -- operating context for the AI agentPROJECT.md-- comprehensive board-ready report for the userK8S.md-- kubernetes architecture deep-dive (for a future session)TODO.md-- pending user actions (tsys2 hardware commands, Friday plan)
Current state (as of 2026-07-27)
DONE — 5 of 7 hosts fully optimized and validated
| Host | Status | Notes |
|---|---|---|
| pfv-tsys1 | COMPLETE | 11 VMs, infra host, USB for HA/CA |
| pfv-tsys3 | COMPLETE | 1 VM, laptop, kernel 7.0.14 (skewed) |
| pfv-tsys6 | COMPLETE | 5 VMs, bond layer3+4, LACP 1.83 Gbps confirmed |
| pfv-tsys7 | COMPLETE | 4 VMs, bond layer3+4, LACP 1.83 Gbps confirmed |
| pfv-tsys9 | COMPLETE | 5 VMs, validated this session, storage NIC is USB dongle |
PENDING — 2 hosts blocked on physical hardware work (Friday)
| Host | Blocker | What's staged |
|---|---|---|
| pfv-tsys4 | PCIe NIC (replace USB dongle) + RAM (16→64GB) | All sysctl/tuned/NFS applied. DO NOT reboot until hardware installed. |
| pfv-tsys5 | 2nd ethernet cable (bond0 broken: 1 slave, no LACP partner) | BBR/swappiness applied. NFS staged. Reboot after cable + layer3+4 hash. |
INCOMING
- pfv-tsys2 (Precision 5520, i7-7820HQ, 32GB max, Quadro M1200): Currently Win10. Will be rebuilt as Proxmox. K8s-dedicated host. Hardware validated 2026-07-27: 2 SSDs (Samsung 960 PRO NVMe 512GB + Samsung 850 EVO SATA 1TB) -- best local storage in fleet. Both NICs are USB dongles (ASIX + Realtek) -- unavoidable on laptop, no PCIe NIC option.
- tsys5 NVMe: PCI NVMe drive being added Friday. Recommend local-only (not NFS-exported) for VM images.
Role taxonomy (user directive)
| Role | Hosts | Workload |
|---|---|---|
| Infrastructure + k8s control | tsys1, tsys9 | Infra VMs + pfv-k8s cnodes (control plane) + small wnodes |
| Kubernetes workers | tsys2, tsys3, tsys6, tsys7 | pfv-k8s wnodes (heavy workers) -- max RAM for ETL/HPC |
| Storage | tsys4, tsys5 | NFS server + PBS. tsys5 also runs sectestbed. |
Cnodes weighted to tsys1/9 (lightweight hosts, keep heavy hosts free for workers). Wnodes: one per hypervisor host across the fleet. Production lives on a VPS in Reston VA (Cloudron) -- this cluster is R&D only.
Critical VM-layer findings (see PROJECT.md + K8S.md for full detail)
- ALL 10 pfv-k8s nodes store disks on tsys4 NFS. tsys4 failure = entire k8s cluster dead. etcd quorum lost.
- Both -01/-02 pairs (netinfra, UCS) on tsys4 NFS only. Both halves die if tsys4 goes down. Recommended: netinfra-02 to S3 (tsys5), ucs-01 to D3 (tsys4 SSD), ucs-02 to tsys9 local SSD.
- No k8s node uses SSD or NVMe. All on NFS-over-HDD. tsys9 has 136 GB unused local SSD; tsys3 has 349 GB unused local NVMe (Samsung PM961).
- D3 SSD (tsys4) is 99% empty (445 GB free). Nobody using the only SSD NFS export. Should host ucs-01 (LDAP/AD latency benefit).
- S2/S3/S4 (tsys5) are all 99% empty. Secondary storage server barely used. VMs should be rebalanced to reduce tsys4 blast radius.
- tsys6/7 local-lvm is USB 2.0 portable HDD (WD My Passport, ~30 MB/s). Slower than NFS-HDD. Do NOT use for VM storage. Entire Proxmox OS on these hosts boots from USB 2.0 -- user accepts this risk.
Storage network IPs (VLAN1000, 10.100.100.0/24)
tsys1=.1 tsys3=.3 tsys4=.4 tsys5=.5 tsys6=.6 tsys7=.7 tsys9=.9
NFS export topology
tsys4 exports (primary, overloaded):
- D2 = WDC Red 3TB HDD — most VMs live here
- D5 = Hitachi 2TB HDD
- (sda Hitachi 1.8T at /mnt/albert — not NFS shared)
- (sdd WDC 1T — idle, unmounted, removable)
- (sdf WDC 4.5T SMR at /mnt/backup — PBS target)
tsys5 exports (fast-tier hub -- consolidated Friday):
- S1/S2/S3 = Seagate 1TB HDD each
- S4 = Toshiba 500GB HDD
- T5-SSD = Samsung 860 PRO 256GB SSD (existing)
- D3 = SK hynix SC300 512GB SSD (moving from tsys4 USB to tsys5 SAS Friday)
- NVMe (local, new Friday) — local-only, wnode-tsys5 boot + HPC scratch
tsys5 hardware: LSI SAS1068E (8-port, 5 free) + Intel ICH10 SATA (6-port, 2 free) + 2x Renesas USB 3.0 xHCI. Plenty of room for the SSD + NVMe.
Friday change: D3 export repoints from pfv-tsys4-nfs-stor to pfv-tsys5-nfs-stor. Update storage.cfg cluster-wide. VMs on D3 (currently none of significance — it's 99% empty) keep working after remount.
SSH access
SSH keys deployed to root on all hosts. Direct ssh/scp blocked in Crush bash;
use deploy-check.sh / deploy-tuning.sh wrapper patterns instead.
Critical lessons (do NOT regress)
- NFS
optionsline in storage.cfg must NOT includeversion=4.2— Proxmox sets NFS version separately. Use onlyoptions nconnect=4,noatime. - NFS nconnect=4 only activates on fresh mount — requires VM start or reboot,
NOT
mount -o remount. - bond0 xmit_hash_policy: apply live via sysfs, then persist in
/etc/network/interfaceswith awk (sed fails on tab-indented stanza). - Always shellcheck before shipping:
docker run --rm -v "$PWD:/mnt" koalaman/shellcheck:stable --severity=style scripts/*.sh - The hosts appear to be standalone Proxmox installs, not a shared cluster (storage.cfg differs per host). VMs are pinned to their host. Moving VMs requires manual disk migration, not live migration.
Friday walkthrough (user action)
Step 1: tsys5 storage cable + NVMe
- Plug 2nd ethernet cable into tsys5 storage NIC
- Verify:
cat /proc/net/bonding/bond0— need "Number of ports: 2" + partner MAC - Apply:
echo "layer3+4" > /sys/class/net/bond0/bonding/xmit_hash_policy - Install PCI NVMe, format as directory storage (local-only)
- Reboot tsys5
Step 2: tsys4 hardware install
- Install PCIe NIC + add RAM (16→64 GB)
- Update
/etc/network/interfaces— replaceenx8cae4ccda926with new NIC - Reboot tsys4 (PBS VM restarts — OK)
Step 3: Post-hardware validation
iperf-full-matrix.sh— re-test all pathsvalidate-fixes.sh pfv-tsys4andvalidate-fixes.sh pfv-tsys5- Update PROJECT.md with post-hardware numbers
Version control
This project is tracked in a local git repo (main branch). Use atomic
commits with conventional commit messages (e.g., docs: add disk utilization to storage section, feat: add tsys9 validation support). Never push to
remote unless explicitly asked.
Key scripts
| Script | Purpose |
|---|---|
scripts/check.sh |
Read-only data collector |
scripts/apply-tunings.sh |
Tier 0 tunings (dry-run/apply/rollback) |
scripts/fix-bond-nfs.sh |
Fix NFS options + bond hash |
validate-fixes.sh |
Validation of all applied changes |
iperf-full-matrix.sh |
Full iperf suite |
deploy-check.sh |
Deploy check.sh to hosts via SSH |