Panasonic Switch-M8eG PN28080K is a 8 + 1 port gigabit switch, based on
RTL8380M.
Specification:
- SoC : Realtek RTL8380M
- RAM : DDR3 128 MiB (Winbond W631GG8KB-15)
- Flash : SPI-NOR 32 MiB (Macronix MX25L25635FMI-10G)
- Ethernet : 10/100/1000 Mbps x8 + 1
- port 1-8 : TP, RTL8218B (SoC)
- port 9 : SFP, RTL8380M (SoC)
- LEDs/Keys : 7x / 1x
- UART : RS-232 port on the front panel (connector: RJ-45)
- 3:TX, 4:GND, 5:GND, 6:RX (pin number: RJ-45)
- 9600n8
- Power : 100-240 VAC, 50/60 Hz, 0.5 A
- Plug : IEC 60320-C13
- Stock OS : VxWorks based
Flash instruction using initramfs image:
1. Prepare the TFTP server with the IP address 192.168.1.111
2. Rename the OpenWrt initramfs image to "0101A8C0.img" and place it to
the TFTP directory
3. Download the official upgrading firmware (ex: pn28080k_v30000.rom)
and place it to the TFTP directory
4. Boot M8eG and interrupt the U-Boot with Ctrl + C keys
5. Execute the following commands and boot with the OpenWrt initramfs
image
rtk network on
tftpboot 0x81000000
bootm
6. Backup mtdblock files to the computer by scp or anything and reboot
7. Interrupt the U-Boot and execute the following commands to re-create
filesystem in the flash
ffsmount c:/
ffsfmt c:/
this step takes a long time, about ~ 4 mins
8. Execute the following commands to put the official images to the
filesystem
updatert <official image>
example:
updatert pn28080k_v30000.rom
this step takes about ~ 40 secs
9. Set the environment variables of the U-Boot by the following commands
setenv loadaddr 0xb4e00000
setenv bootcmd bootm
saveenv
10: Download the OpenWrt initramfs image and boot with it
tftpboot 0x81000000 0101A8C0.img
bootm
11: On the initramfs image, download the sysupgrade image and perform
sysupgrade with it
sysupgrade <imagename>
12: Wait ~ 120 seconds to complete flashing
Note:
- "Switch-M8eG" is a model name, and "PN28080K" is a model number.
Switch-M8eG has an another (old) model number ("PN28080"), it's not a
Realtek based hardware.
- Switch-M8eG has a "POWER" LED (Green), but it's not connected to any
GPIO pin.
- The U-Boot checks the runtime images in the flash when booting and
fails to execute anything in "bootcmd" variable if the images are not
exsisting.
- A filesystem is formed in the flash (0x100000-0x1DFFFFF) on the stock
firmware and it includes the stock images, configuration files and
checksum files. It's unknown format, can't be managed on the OpenWrt.
To get the enough space for OpenWrt, move the filesystem to the head
of "fs_reserved" partition by execution of "ffsfmt" and "updatert".
- On the other devices in the same series of Switch-M8eG PN28080K, the
INT pin on the PCA9555 is not connected to anywhere.
Back to the stock firmware:
1. Delete "loadaddr" variable and set "bootcmd" to the original value
on U-Boot:
setenv loadaddr
setenv bootcmd 'bootm 0x81000000'
on OpenWrt:
fw_setenv loadaddr
fw_setenv bootcmd 'bootm 0x81000000'
2. Perform reset or reboot
on U-Boot:
reset
on OpenWrt:
reboot
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Reviewed-by: Sander Vanheule <sander@svanheule.net>
The system status LED on Panasonic Switch-M8eG PN28080K is connected to
a PCA9539PW. To use the LED as a status LED of OpenWrt while booting,
enable the pca953x driver and built-in to the kernel.
Also enable CONFIG_GPIO_PCA953X_IRQ to use interrupt via RTL83xx GPIO.
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Acked-by: Sander Vanheule <sander@svanheule.net>
The ZyXEL GS1900-24 v1 is a 24 port switch with two SFP ports, similar to
the other GS1900 switches.
Specifications
--------------
* Device: ZyXEL GS1900-24 v1
* SoC: Realtek RTL8382M 500 MHz MIPS 4KEc
* Flash: 16 MiB
* RAM: Winbond W9751G8KB-25 64 MiB DDR2 SDRAM
* Ethernet: 24x 10/100/1000 Mbps, 2x SFP 100/1000 Mbps
* LEDs:
* 1 PWR LED (green, not configurable)
* 1 SYS LED (green, configurable)
* 24 ethernet port link/activity LEDs (green, SoC controlled)
* 2 SFP status/activity LEDs (green, SoC controlled)
* Buttons:
* 1 "RESET" button on front panel (soft reset)
* 1 button ('SW1') behind right hex grate (hardwired power-off)
* Power: 120-240V AC C13
* UART: Internal populated 10-pin header ('J5') providing RS232;
connected to SoC UART through a SIPEX 3232EC for voltage
level shifting.
* 'J5' RS232 Pinout (dot as pin 1):
2) SoC RXD
3) GND
10) SoC TXD
Serial connection parameters: 115200 8N1.
Installation
------------
OEM upgrade method:
* Log in to OEM management web interface
* Navigate to Maintenance > Firmware > Management
* If "Active Image" has the first option selected, OpenWrt will need to be
flashed to the "Active" partition. If the second option is selected,
OpenWrt will need to be flashed to the "Backup" partition.
* Navigate to Maintenance > Firmware > Upload
* Upload the openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-initramfs-kernel.bin
file by your preferred method to the previously determined partition.
When prompted, select to boot from the newly flashed image, and reboot
the switch.
* Once OpenWrt has booted, scp the sysupgrade image to /tmp and flash it:
> sysupgrade /tmp/openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-squashfs-sysupgrade.bin
U-Boot TFTP method:
* Configure your client with a static 192.168.1.x IP (e.g. 192.168.1.10).
* Set up a TFTP server on your client and make it serve the initramfs
image.
* Connect serial, power up the switch, interrupt U-boot by hitting the
space bar, and enable the network:
> rtk network on
> Since the GS1900-24 v1 is a dual-partition device, you want to keep the
OEM firmware on the backup partition for the time being. OpenWrt can
only be installed in the first partition anyway (hardcoded in the
DTS). To ensure we are set to boot from the first partition, issue the
following commands:
> setsys bootpartition 0
> savesys
* Download the image onto the device and boot from it:
> tftpboot 0x81f00000 192.168.1.10:openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-initramfs-kernel.bin
> bootm
* Once OpenWrt has booted, scp the sysupgrade image to /tmp and flash it:
> sysupgrade /tmp/openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-squashfs-sysupgrade.bin
Signed-off-by: Martin Kennedy <hurricos@gmail.com>
I-O DATA BSH-G24MB is a 24 port gigabit switch, based on RTL8382M.
Specification:
- SoC : Realtek RTL8382M
- RAM : DDR2 128 MiB (Nanya NT5TU128M8HE-AC)
- Flash : SPI-NOR 16 MiB (Macronix MX25L12835FM2I-10G)
- Ethernet : 10/100/1000 Mbps x24
- port 1-8 : RTL8218B
- port 9-16 : RTL8218B (SoC)
- port 17-24 : RTL8218B
- LEDs/Keys : 2x, 1x
- UART : pin header on PCB
- JP2: 3.3V, TX, RX, GND from rear side
- 115200n8
- Power : 100 VAC, 50/60 Hz
- Plug : IEC 60320-C13
Flash instruction using sysupgrade image:
1. Boot BSH-G24MB normally
2. Connect BSH-G24MB to the DHCP enabled network
3. Find the device's IP address and open the WebUI and login
Note: by default, the device obtains IP address from DHCP server of
the network
4. Open firmware update page ("ファームウェア アップデート")
5. Rename the OpenWrt sysupgrade image to "bsh-g24mb_v100.image" and
select it
6. Press apply ("適用") button to perform update
7. Wait ~150 seconds to complete flashing
Note:
- BSH-G24MB has a power-related LED ("電源"), but it's not connected to
the GPIO of the SoC or RTL8231 and cannot be controlled. Instead of
it, use system status LED on other than running-state.
- "sys_loop" LED indicates system status and loop-detection status in
stock firmware.
- BSH-G24MB has 2x os-image partitions named as "RUNTIME"/"RUNTIME2" in
16 MiB SPI-NOR flash and the size of image per partition is only
6848 KiB. The secondary image is never used on stock firmware, so also
use it on OpenWrt to get more space.
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Ensures that the DSA driver sets exactly the same default flags as the
bridge when a port joins or leaves. Without this we end up with a
confusing flag mismatch, where DSA and bridge ports use different sets
of flags.
This is critical as the "learning" mismatch will be harmful to the
network, causing all traffic to be flooded on all ports.
The original commit was buggy, trying to set the flags one-by-one in a
loop. This was not supported by the API and the end result was that
all but the last flag were cleared. This bug was implicitly fixed
upstream by commit e18f4c18ab5b ("net: switchdev: pass flags and mask
to both {PRE_,}BRIDGE_FLAGS attributes").
This is a minimum temporary stop measure fix for the critical lack of
"learning" only. The major API change associated with a full v5.12+
backport is neither required nor wanted. A simpler fix, moving the
call to dsa_port_bridge_flags() out of the loop, has therefore been
merged into this modified backport.
Fixes: afa3ab54c0 ("realtek: Backport bridge configuration for DSA")
Signed-off-by: Bjørn Mork <bjorn@mork.no>
Acked-by: Daniel Golle <daniel@makrotopia.org>
Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
[fix typos in commit message]
Signed-off-by: Stijn Tintel <stijn@linux-ipv6.be>
The I/O base address for the timers was hardcoded into the driver,
or derived from the HW IRQ number as an even more horrible hack. All
supported SoC families have these timers, but with hardcoded addresses
the code cannot be reused right now.
Request the timer's base address from the DT specification, and store it
in a private struct for future reference.
Matching the second interrupt specifier, the address range for the
second timer is added to the DT specification.
Signed-off-by: Sander Vanheule <sander@svanheule.net>
The Realtek timer node for RTL930x doesn't have any child nodes, making
the use of '#address-cells' quite pointless. It is also not an interrupt
controller, meaning it makes no sense to define '#interrupt-cells'.
The I/O address for this node is also wrong, but this is hidden by the
fact that the driver associated with this node bypasses the usual DT
machinery and does it's own thing. Correct the address to have a sane
value, even though it isn't actually used.
Fixes: a75b9e3ecb ("realtek: Adding RTL930X sub-target")
Signed-off-by: Sander Vanheule <sander@svanheule.net>
When driven by a GPIO pin, the system LED needs to be configured as
active high. Otherwise the LED switches off after booting and
initialisation.
Fixes: 47f5a0a3ee ("realtek: Add support for ZyXEL GS1900-48 Switch")
Signed-off-by: Sander Vanheule <sander@svanheule.net>
The default value for a DT node's status property is already "okay", so
there's no need to specify it again. Drop the status property to clean
up the DTS.
Signed-off-by: Sander Vanheule <sander@svanheule.net>
The assigned output index for the event timers was quite low, lower even
than the ethernet interrupt. This means that high network load could
preempt timer interrupts, possibly leading to all sorts of strange
behaviour.
Increase the interrupt output index of the event timers to 5, which is
the highest priority output and corresponds to the (otherwise unused)
MIPS CPU timer interrupt.
Fixes: a75b9e3ecb ("realtek: Adding RTL930X sub-target")
Signed-off-by: Sander Vanheule <sander@svanheule.net>
The RTL8231 is an external chip, and not part of the SoC. That means
it is more appropriate to define it in the board specific (base) files,
instead of the DT include for the SoC itself.
Moving the RTL8231 definition also ensures that boards with no GPIO
expander, or an alternative one, don't have a useless gpio1 node label
defined.
Tested on a Netgear GS110TPPv1.
Signed-off-by: Sander Vanheule <sander@svanheule.net>
The address in some node names doesn't match the actual offset specified
in the DT node. Update the names to fix this.
While fixing the node names, also drop the unused node labels.
Fixes: 0a7565e536 ("realtek: Update rtl839x.dtsi for realtek,rtl-intc, new gpio controller remove RTL8231 node")
Signed-off-by: Sander Vanheule <sander@svanheule.net>
Bootargs for devices in the realtek target were previously consolidated
in commit af2cfbda2b ("realtek: Consolidate bootargs"), since all
devices currently use the same arguments.
Commit a75b9e3ecb ("realtek: Adding RTL930X sub-target") reverted this
without any argumentation, so let's undo that.
Commit 0b8dfe0851 ("realtek: Add RTL931X sub-target") introduced the
old bootargs also for RTL931x, without providing any actual device
support. Until that is done, let's assume vendors will have done what
they did before, and use a baud rate of 115200.
Fixes: a75b9e3ecb ("realtek: Adding RTL930X sub-target")
Signed-off-by: Sander Vanheule <sander@svanheule.net>
A Locking bug in the packet receive path was introduced with PR
#4973. The following patch prevents the driver from locking
after a few minutes with an endless flow of
[ 1434.185085] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000f8
[ 1434.208971] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000fc
[ 1434.794800] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000fc
[ 1435.049187] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000fc
Signed-off-by: Bjørn Mork <bjorn@mork.no>
Signed-off-by: Birger Koblitz <mail@birger-koblitz.de>
When initialising the driver, check if the RTL8231 chip is actually
present at the specified address. If the READY_CODE value does not match
the expected value, return -ENXIO to fail probing.
This should help users to figure out which address an RTL8231 is
configured to use, if measuring pull-up/-down resistors is not an
option.
On an unsuccesful probe, the driver will log:
[ 0.795364] Probing RTL8231 GPIOs
[ 0.798978] rtl8231_init called, MDIO bus ID: 30
[ 0.804194] rtl8231-gpio rtl8231-gpio: no device found at bus address 30
When a device is found, only the first two lines will be logged:
[ 0.453698] Probing RTL8231 GPIOs
[ 0.457312] rtl8231_init called, MDIO bus ID: 31
Signed-off-by: Sander Vanheule <sander@svanheule.net>
Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
The SMI bus ID for RTL8231 currently defaults to 0, and can be
overridden from the devicetree. However, there is no value check on the
DT-provided value, aside from masking which would only cause value
wrap-around.
Change the driver to always require the "indirect-access-bus-id"
property, as there is no real reason to use 0 as default, and perform a
sanity check on the value when probing. This allows the other parts of
the driver to be simplified a bit.
Signed-off-by: Sander Vanheule <sander@svanheule.net>
Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
Set the gpio_chip.base to -1 to use automatic GPIO line indexing.
Setting base to 0 or a positive number is deprecated and should not be
used.
Signed-off-by: Sander Vanheule <sander@svanheule.net>
Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
The RTL8231's gpio_chip.ngpio was set to 36, which is the largest valid
GPIO index. Fix the allowed number of GPIOs by setting ngpio to 37, the
actual line count.
Reported-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Signed-off-by: Sander Vanheule <sander@svanheule.net>
Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
Replace magic values with more self-descriptive code now that I start
to understand more about the design of the PHY (and MDIO controller).
Remove one line before reading RTL8214FC internal PHY id which turned
out to be a no-op and can hence safely be removed (confirmed by
INAGAKI Hiroshi[1])
[1]: df8e6be59a (r66890713)
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
Instead of directly calling SoC-specific functions in order to access
(paged) MII registers or MMD registers, create infrastructure to allow
using the generic phy_*, phy_*_paged and phy_*_mmd functions.
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
* Add missing Clause-45 write support for rtl931x
* Switch to use helper functions in all Clause-45 access functions to
make the code more readable.
* More meaningful/unified debugging output (dynamic kprintf)
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
Import commit ("c6af53f038aa3 net: mdio: add helpers to extract clause
45 regad and devad fields") from Linux 5.17 to allow making the MDIO
code in the ethernet driver more readable.
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
Using the led-set attribute of a port in the dts we allow configuration
of the port leds. Each led-set is being defined in the led-set configuration
of the .dts, giving a specific configuration to steer the port LEDs via a serial
connection.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
The RTL8221B PHY is a newer version of the RTL8226, also supporting
2.5GBit Ethernet. It is found with RTL931X devices such as the
EdgeCore ECS4125-10P
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Both the Aquantia AQR113c and the RTL8226 PHYs in the Zyxel XGS1250 and the
Zyxel XGS1210 require special polling configuration settings in the
RTL930X_SMI_10GPHY_POLLING_REGxx_CFG configuration registers. Set them.
Additionally, for RTL 1GBit phys set the RTL930X_SMI_PRVTE_POLLING_CTRL bits
in the poll mask.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
For SFP slots on the RTL9302, the link status is not correctly detected.
Use the link media status instead.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
We add the RTL931X sub-target with kernel configuration for
a dual core MIPS InterAptive CPU.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
We add HW support routines for the RTL931X SoC family for handling
the Packet Inspection Engine, L2 table handling and STP aging.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
We need to store and restore MC memberships in HW when a port joins or
leaves a bridge as well as when it is enabled or disabled, as these
properties should not change in these situations.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
In order to receive STP information at the kernel level, we make sure
that all Bridge Protocol Data Units are copied to the CPU-Port.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Instead of a generic L2 aging configuration function with complex
logic, we implement an individual function for all SoC types.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Add functionality to enable or disable L2 learning offload and port flooding
for RTL83XX.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Adds the DSA API for bridge configuration (flooding, L2 learning,
and aging) offload as found in Linux 5.12 so that we can implement
it in our drivver.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
This adds LAG support for all 4 SoC families, including support
ofr the use of different distribution algorithm for the load-
balancing between individual links.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Add the LAG configuration API for DSA as found in Linux 5.12 so that we
can implement it in the dsa driver.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Use setting functions instead of register numbers in order to clean up the code.
Also use enums to define inner/outer VLAN types and the filter type.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
The ZyXEL XGS1250-12 Switch is a 11 + 1 port multi-GBit switch with
8 x 1000BaseT, 3 x 1000/2500/5000/10000BaseT Ethernet ports and
1 SFP+ module slot.
Hardware:
- RTL9302B SoC
- Macronix MX25L12833F (16MB flash)
- Nanja NT5CC64M16GP-1 (128MB DDR3 SDRAM)
- RTL8231 GPIO extender to control the port LEDs
- RTL8218D 8x Gigabit PHY
- Aquantia AQR113c 1/2.5/5/10 Gigabit PHYs
- SFP+ 10GBit slot
Power is supplied via a 12V 2A standard barrel connector. At the
right side behind the grid is UART serial connector. A Serial
header can be connected to from the outside of the switch trough
the airvents with a standard 2.54mm header.
Pins are from top to bottom Vcc(3.3V), TX, RX and GND. Serial
connection is via 115200 baud, 8N1.
A reset button is accessble through a hole in the front panel
At the time of this commit, all ethernet ports work under OpenWRT,
including the various NBaseT modes, however the 10GBit SFP+ slot is not
supported.
Installation
--------------
* Connect serial as per the layout above. Connection parameters: 115200 8N1.
* Navigate to 'Management' in the OEM web interface and click on 'Firmware upgrade'
to the left.
* Upload the OpenWrt initramfs image, and wait till the switch reboots.
* Connect to the device through serial and change the U-boot boot command.
> fw_setenv bootcmd 'rtk network on; boota'
* Reboot, scp the sysupgrade image to /tmp, verify the checksum and flash it:
> sysupgrade /tmp/openwrt-realtek-rtl930x-zyxel_xgs1250-12-squashfs-sysupgrade.bin
* Upon reboot, you have a functional OpenWrt installation. Leave the bootcmd
value as is - without 'rtk network on' the switch will fail to initialise
the network.
Web recovery
------------
The XGS1250-12 has a handy web recovery that will load when U-boot does
not find a bootable kernel. In case you would like to trigger the web
recovery manually, partially overwrite the firmware partition with some
zeroes:
# dd if=/dev/zero of=/dev/mtd5 bs=1M count=2
If you have serial connected you'll see U-boot will start the web recovery
and print it's listening on 192.168.1.1, but by default it seems to be on
the OEM default IP for the switch - 192.168.1.3. The web recovery only
listens on HTTP (80) and *not* on 443 (HTTPS) unlike the web UI.
Return to stock
---------------
You can flash the ZyXEL firmware images to return to stock:
# sysupgrade -F -n XGS1250-12_Firmware_V1.00(ABWE.1)C0.bix
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Adds configuration routines for the internal SerDes of the
RTL930X and RTL931X.
Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com>
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
Adds a rtl931x_phylink_mac_config for the RTL931X and improve
the handling of the RTL930X phylink configuration. Add separate
handling of the RTL839x since some configurations are different
from the RTL838X.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
We were using the PHY-ids (the reg entries in the PHY
sections of the .dts) as the port numbers. Now scan the
ports section in the .dts, and use the actual port numbers,
following the phy-handle to the PHY properties.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
When a port is brought up, read the SDS-id via the phy_device
for a given port and use this to configure the SDS when it
is brought up.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
The RTL839X does not have an internal phy and thus does not need to have any
firmware as part of the kernel, especially not firmware for the RTL838X.
Signed-off-by: Birger Koblitz <git@birger-koblitz.de>