openwrt/target/linux/ath79/dts/qca9557_engenius_enstationac-v1.dts

111 lines
1.8 KiB
Plaintext
Raw Normal View History

ath79: add support for Senao Engenius EnStationAC v1 FCC ID: A8J-ENSTAC Engenius EnStationAC v1 is an outdoor wireless access point/bridge with 2 gigabit ethernet ports on 2 external ethernet switches, 5 GHz only wireless, internal antenna plates, and proprietery PoE. Specification: - QCA9557 SOC - QCA9882 WLAN (PCI card, 5 GHz, 2x2, 26dBm) - AR8035-A switch (RGMII GbE with PoE+ IN) - AR8031 switch (SGMII GbE with PoE OUT) - 40 MHz reference clock - 16 MB FLASH MX25L12845EMI-10G - 2x 64 MB RAM NT5TU32M16FG - UART at J10 (unpopulated) - internal antenna plates (19 dbi, directional) - 7 LEDs, 1 button (power, eth, wlan, RSSI) (reset) MAC addresses: MAC addresses are labeled as ETH and 5GHz Vendor MAC addresses in flash are duplicate eth0 ETH *:d3 art 0x0/0x6 eth1 ---- *:d4 --- phy0 5GHz *:d5 --- Installation: 2 ways to flash factory.bin from OEM: - if you get Failsafe Mode from failed flash: only use it to flash Original firmware from Engenius or risk kernel loop or halt which requires serial cable Method 1: Firmware upgrade page: OEM webpage at 192.168.1.1 username and password "admin" Navigate to "Firmware" page from left pane Click Browse and select the factory.bin image Upload and verify checksum Click Continue to confirm and wait 3 minutes Method 2: Serial to load Failsafe webpage: After connecting to serial console and rebooting... Interrupt uboot with any key pressed rapidly execute `run failsafe_boot` OR `bootm 0x9fd70000` wait a minute connect to ethernet and navigate to "192.168.1.1/index.htm" Select the factory.bin image and upload wait about 3 minutes Return to OEM: If you have a serial cable, see Serial Failsafe instructions otherwise, uboot-env can be used to make uboot load the failsafe image *DISCLAIMER* The Failsafe image is unique to Engenius boards. If the failsafe image is missing or damaged this will not work DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt ssh into openwrt and run `fw_setenv rootfs_checksum 0` reboot, wait 3 minutes connect to ethernet and navigate to 192.168.1.1/index.htm select OEM firmware image from Engenius and click upgrade TFTP recovery: rename initramfs to 'vmlinux-art-ramdisk' make available on TFTP server at 192.168.1.101 power board hold or press reset button repeatedly NOTE: for some Engenius boards TFTP is not reliable try setting MTU to 600 and try many times Format of OEM firmware image: The OEM software of EnStationAC is a heavily modified version of Openwrt Altitude Adjustment 12.09. One of the many modifications is to the sysupgrade program. Image verification is performed simply by the successful ungzip and untar of the supplied file and name check and header verification of the resulting contents. To form a factory.bin that is accepted by OEM Openwrt build, the kernel and rootfs must have specific names... openwrt-ar71xx-enstationac-uImage-lzma.bin openwrt-ar71xx-enstationac-root.squashfs and begin with the respective headers (uImage, squashfs). Then the files must be tarballed and gzipped. The resulting binary is actually a tar.gz file in disguise. This can be verified by using binwalk on the OEM firmware images, ungzipping then untaring. Newer EnGenius software requires more checks but their script includes a way to skip them, otherwise the tar must include a text file with the version and md5sums in a deprecated format. The OEM upgrade script is at /etc/fwupgrade.sh. OKLI kernel loader is required because the OEM software expects the kernel to be no greater than 1536k and the factory.bin upgrade procedure would otherwise overwrite part of the kernel when writing rootfs. Note on PLL-data cells: The default PLL register values will not work because of the external AR8033 switch between the SOC and the ethernet PHY chips. For QCA955x series, the PLL registers for eth0 and eth1 can be see in the DTSI as 0x28 and 0x48 respectively. Therefore the PLL registers can be read from uboot for each link speed after attempting tftpboot or another network action using that link speed with `md 0x18050028 1` and `md 0x18050048 1`. For eth0 at 1000 speed, the value returned was ae000000 but that didn't work, so following the logical pattern from the rest of the values, the guessed value of a3000000 works better. later discovered that delay can be placed on the PHY end only with phy-mode as 'rgmii-id' and set register to 0x82... Tested from master, all link speeds functional Signed-off-by: Michael Pratt <mcpratt@pm.me> [fixed SoB to match From:] Signed-off-by: Petr Štetiar <ynezz@true.cz>
2020-08-25 04:17:28 +00:00
// SPDX-License-Identifier: GPL-2.0-or-later OR MIT
#include "qca955x_senao_loader.dtsi"
ath79: add support for Senao Engenius EnStationAC v1 FCC ID: A8J-ENSTAC Engenius EnStationAC v1 is an outdoor wireless access point/bridge with 2 gigabit ethernet ports on 2 external ethernet switches, 5 GHz only wireless, internal antenna plates, and proprietery PoE. Specification: - QCA9557 SOC - QCA9882 WLAN (PCI card, 5 GHz, 2x2, 26dBm) - AR8035-A switch (RGMII GbE with PoE+ IN) - AR8031 switch (SGMII GbE with PoE OUT) - 40 MHz reference clock - 16 MB FLASH MX25L12845EMI-10G - 2x 64 MB RAM NT5TU32M16FG - UART at J10 (unpopulated) - internal antenna plates (19 dbi, directional) - 7 LEDs, 1 button (power, eth, wlan, RSSI) (reset) MAC addresses: MAC addresses are labeled as ETH and 5GHz Vendor MAC addresses in flash are duplicate eth0 ETH *:d3 art 0x0/0x6 eth1 ---- *:d4 --- phy0 5GHz *:d5 --- Installation: 2 ways to flash factory.bin from OEM: - if you get Failsafe Mode from failed flash: only use it to flash Original firmware from Engenius or risk kernel loop or halt which requires serial cable Method 1: Firmware upgrade page: OEM webpage at 192.168.1.1 username and password "admin" Navigate to "Firmware" page from left pane Click Browse and select the factory.bin image Upload and verify checksum Click Continue to confirm and wait 3 minutes Method 2: Serial to load Failsafe webpage: After connecting to serial console and rebooting... Interrupt uboot with any key pressed rapidly execute `run failsafe_boot` OR `bootm 0x9fd70000` wait a minute connect to ethernet and navigate to "192.168.1.1/index.htm" Select the factory.bin image and upload wait about 3 minutes Return to OEM: If you have a serial cable, see Serial Failsafe instructions otherwise, uboot-env can be used to make uboot load the failsafe image *DISCLAIMER* The Failsafe image is unique to Engenius boards. If the failsafe image is missing or damaged this will not work DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt ssh into openwrt and run `fw_setenv rootfs_checksum 0` reboot, wait 3 minutes connect to ethernet and navigate to 192.168.1.1/index.htm select OEM firmware image from Engenius and click upgrade TFTP recovery: rename initramfs to 'vmlinux-art-ramdisk' make available on TFTP server at 192.168.1.101 power board hold or press reset button repeatedly NOTE: for some Engenius boards TFTP is not reliable try setting MTU to 600 and try many times Format of OEM firmware image: The OEM software of EnStationAC is a heavily modified version of Openwrt Altitude Adjustment 12.09. One of the many modifications is to the sysupgrade program. Image verification is performed simply by the successful ungzip and untar of the supplied file and name check and header verification of the resulting contents. To form a factory.bin that is accepted by OEM Openwrt build, the kernel and rootfs must have specific names... openwrt-ar71xx-enstationac-uImage-lzma.bin openwrt-ar71xx-enstationac-root.squashfs and begin with the respective headers (uImage, squashfs). Then the files must be tarballed and gzipped. The resulting binary is actually a tar.gz file in disguise. This can be verified by using binwalk on the OEM firmware images, ungzipping then untaring. Newer EnGenius software requires more checks but their script includes a way to skip them, otherwise the tar must include a text file with the version and md5sums in a deprecated format. The OEM upgrade script is at /etc/fwupgrade.sh. OKLI kernel loader is required because the OEM software expects the kernel to be no greater than 1536k and the factory.bin upgrade procedure would otherwise overwrite part of the kernel when writing rootfs. Note on PLL-data cells: The default PLL register values will not work because of the external AR8033 switch between the SOC and the ethernet PHY chips. For QCA955x series, the PLL registers for eth0 and eth1 can be see in the DTSI as 0x28 and 0x48 respectively. Therefore the PLL registers can be read from uboot for each link speed after attempting tftpboot or another network action using that link speed with `md 0x18050028 1` and `md 0x18050048 1`. For eth0 at 1000 speed, the value returned was ae000000 but that didn't work, so following the logical pattern from the rest of the values, the guessed value of a3000000 works better. later discovered that delay can be placed on the PHY end only with phy-mode as 'rgmii-id' and set register to 0x82... Tested from master, all link speeds functional Signed-off-by: Michael Pratt <mcpratt@pm.me> [fixed SoB to match From:] Signed-off-by: Petr Štetiar <ynezz@true.cz>
2020-08-25 04:17:28 +00:00
#include <dt-bindings/gpio/gpio.h>
#include <dt-bindings/input/input.h>
/ {
compatible = "engenius,enstationac-v1", "qca,qca9557";
model = "EnGenius EnStationAC v1";
aliases {
label-mac-device = &eth0;
led-boot = &led_power;
led-failsafe = &led_power;
led-running = &led_power;
led-upgrade = &led_power;
};
keys {
compatible = "gpio-keys";
reset {
label = "reset";
gpios = <&gpio 17 GPIO_ACTIVE_LOW>;
debounce-interval = <60>;
linux,code = <KEY_RESTART>;
};
};
leds {
compatible = "gpio-leds";
led_power: power {
label = "amber:power";
gpios = <&gpio 22 GPIO_ACTIVE_LOW>;
default-state = "on";
};
wlan {
label = "green:wlan";
gpios = <&gpio 21 GPIO_ACTIVE_LOW>;
linux,default-trigger = "phy0tpt";
};
rssilow {
label = "red:rssilow";
gpios = <&gpio 19 GPIO_ACTIVE_LOW>;
};
rssimedium {
label = "amber:rssimedium";
gpios = <&gpio 23 GPIO_ACTIVE_LOW>;
};
rssihigh {
label = "green:rssihigh";
gpios = <&gpio 18 GPIO_ACTIVE_LOW>;
};
};
};
&partitions {
art: partition@ff0000 {
label = "art";
reg = <0xff0000 0x010000>;
read-only;
ath79: add support for Senao Engenius EnStationAC v1 FCC ID: A8J-ENSTAC Engenius EnStationAC v1 is an outdoor wireless access point/bridge with 2 gigabit ethernet ports on 2 external ethernet switches, 5 GHz only wireless, internal antenna plates, and proprietery PoE. Specification: - QCA9557 SOC - QCA9882 WLAN (PCI card, 5 GHz, 2x2, 26dBm) - AR8035-A switch (RGMII GbE with PoE+ IN) - AR8031 switch (SGMII GbE with PoE OUT) - 40 MHz reference clock - 16 MB FLASH MX25L12845EMI-10G - 2x 64 MB RAM NT5TU32M16FG - UART at J10 (unpopulated) - internal antenna plates (19 dbi, directional) - 7 LEDs, 1 button (power, eth, wlan, RSSI) (reset) MAC addresses: MAC addresses are labeled as ETH and 5GHz Vendor MAC addresses in flash are duplicate eth0 ETH *:d3 art 0x0/0x6 eth1 ---- *:d4 --- phy0 5GHz *:d5 --- Installation: 2 ways to flash factory.bin from OEM: - if you get Failsafe Mode from failed flash: only use it to flash Original firmware from Engenius or risk kernel loop or halt which requires serial cable Method 1: Firmware upgrade page: OEM webpage at 192.168.1.1 username and password "admin" Navigate to "Firmware" page from left pane Click Browse and select the factory.bin image Upload and verify checksum Click Continue to confirm and wait 3 minutes Method 2: Serial to load Failsafe webpage: After connecting to serial console and rebooting... Interrupt uboot with any key pressed rapidly execute `run failsafe_boot` OR `bootm 0x9fd70000` wait a minute connect to ethernet and navigate to "192.168.1.1/index.htm" Select the factory.bin image and upload wait about 3 minutes Return to OEM: If you have a serial cable, see Serial Failsafe instructions otherwise, uboot-env can be used to make uboot load the failsafe image *DISCLAIMER* The Failsafe image is unique to Engenius boards. If the failsafe image is missing or damaged this will not work DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt ssh into openwrt and run `fw_setenv rootfs_checksum 0` reboot, wait 3 minutes connect to ethernet and navigate to 192.168.1.1/index.htm select OEM firmware image from Engenius and click upgrade TFTP recovery: rename initramfs to 'vmlinux-art-ramdisk' make available on TFTP server at 192.168.1.101 power board hold or press reset button repeatedly NOTE: for some Engenius boards TFTP is not reliable try setting MTU to 600 and try many times Format of OEM firmware image: The OEM software of EnStationAC is a heavily modified version of Openwrt Altitude Adjustment 12.09. One of the many modifications is to the sysupgrade program. Image verification is performed simply by the successful ungzip and untar of the supplied file and name check and header verification of the resulting contents. To form a factory.bin that is accepted by OEM Openwrt build, the kernel and rootfs must have specific names... openwrt-ar71xx-enstationac-uImage-lzma.bin openwrt-ar71xx-enstationac-root.squashfs and begin with the respective headers (uImage, squashfs). Then the files must be tarballed and gzipped. The resulting binary is actually a tar.gz file in disguise. This can be verified by using binwalk on the OEM firmware images, ungzipping then untaring. Newer EnGenius software requires more checks but their script includes a way to skip them, otherwise the tar must include a text file with the version and md5sums in a deprecated format. The OEM upgrade script is at /etc/fwupgrade.sh. OKLI kernel loader is required because the OEM software expects the kernel to be no greater than 1536k and the factory.bin upgrade procedure would otherwise overwrite part of the kernel when writing rootfs. Note on PLL-data cells: The default PLL register values will not work because of the external AR8033 switch between the SOC and the ethernet PHY chips. For QCA955x series, the PLL registers for eth0 and eth1 can be see in the DTSI as 0x28 and 0x48 respectively. Therefore the PLL registers can be read from uboot for each link speed after attempting tftpboot or another network action using that link speed with `md 0x18050028 1` and `md 0x18050048 1`. For eth0 at 1000 speed, the value returned was ae000000 but that didn't work, so following the logical pattern from the rest of the values, the guessed value of a3000000 works better. later discovered that delay can be placed on the PHY end only with phy-mode as 'rgmii-id' and set register to 0x82... Tested from master, all link speeds functional Signed-off-by: Michael Pratt <mcpratt@pm.me> [fixed SoB to match From:] Signed-off-by: Petr Štetiar <ynezz@true.cz>
2020-08-25 04:17:28 +00:00
};
};
&mdio0 {
status = "okay";
phy1: ethernet-phy@1 {
reg = <1>;
eee-broken-100tx;
eee-broken-1000t;
};
phy2: ethernet-phy@2 {
reg = <2>;
eee-broken-100tx;
eee-broken-1000t;
at803x-override-sgmii-link-check;
};
};
&eth0 {
status = "okay";
mtd-mac-address = <&art 0x0>;
phy-handle = <&phy1>;
phy-mode = "rgmii-id";
pll-data = <0x82000000 0x80000101 0x80001313>;
};
&eth1 {
status = "okay";
mtd-mac-address = <&art 0x0>;
mtd-mac-address-increment = <1>;
phy-handle = <&phy2>;
pll-data = <0x03000000 0x00000101 0x00001313>;
qca955x-sgmii-fixup;
};