Driver code such as mfd-core.c may pass 0 as argument n to kcalloc,
which eventually results in an allocation size 0.
res = kcalloc(cell->num_resources, sizeof(*res), GFP_KERNEL);
Since 'res' is checked against NULL for success, kmalloc must not return
a NULL pointer in this case. The patch works around this issue by
forcing an allocation size of 1 byte in this case.
Issue #4253
Clock providers such as drivers/clk/sunxi-ng/ccu-sun8i-r.c don't use
regular init calls but declare their init functions via CLK_OF_DECLARE,
which fill the __clk_of_table. Linux populates the table statically by
using special sections declared in the linker script. In contrast, we
populate the table by expanding the macro to global constructor
functions.
The __clk_of_table is then processed by the call of of_clk_init(NULL).
Issue #4253
* Disable trace source and release ownership on subject destruction.
* Note, since the policy module is also destroyed on descruction of the
session component, the traced component must not access the policy
module when acknowledging the disabled state (else: page fault).
Fixesgenodelabs/genode#4247
If the trace subjects are not properly destructed when the TRACE client
disappears, enabled sources will be owned by a non-existing client.
In other words, when a TRACE client disappears all sources owned by the
client must be disabled.
genodelabs/genode#4247
test-trace always passed, although tracing was never enabled because the
trace subject was not within the first 32 subjects.
* increase number of queried subjects
* output error if trace subject was not found
genodelabs/genode#4247
With this commit, the NIC router DHCP client reads out the first DNS domain
name (DHCP option 15) if any from a DHCP reply that generates an IPv4 config
for a domain and stores the name together with the IPv4 config for that domain.
DNS domain names are reported via the new report tag '<dns-domain>' if the
'config' attribute in the config tag '<report>' is set.
Furthermore, the NIC router DHCP server becomes able to obtain a DNS domain
name from another domain that has a DHCP client dynamically (given the config
attribute 'dns_config_from' is set and no static DNS config is given) or
statically from its configuration (new config tag '<dns-domain>') and propagate
this name with DHCP replies (DHCP option 15).
The 'nic_router_dhcp_*' tests are adapted to test the new feautures.
The commit also gets rid of some mirrored files in
'test/nic_router_dhcp/manager'.
Fixes#4246
WARNING: BREAKS CONFIG COMPATIBILITY!
This commit changes the configuration interface of the NIC router in a way that
may break systems that use the component without proper adjustment!
How to adjust:
At each occurrence of the 'dns_server_from' attribute in a NIC router
configuration replace the attribute name with 'dns_config_from'. The attribute
value remains unaltered.
DETAILED DESCRIPTION
The new attribute name 'dns_config_from' reflects that also other aspects of
the DNS configuration of the denominated domain are used by the DHCP server
that holds the attribute. This commit is a preparation for forwarding also the
domain name (DHCP option 15) with the mechanism behind the attribute.
Ref #4246
The fact that the IPv4 config was a struct with all data members public was a
mere leftover of an early state of the NIC router. Today, the router
implementation style is to avoid structs and public data members wherever
possible.
This commit slightly changes the behavior of the router regarding log output.
The router used to print malformed IPv4 configurations to the log only if
the 'verbose' config flag was set using this style:
! [my_domain] malformed dynamic IP config: interface 10.0.2.1/24 ...
Now, malformed IPv4 configurations are only printed if the
'verbose_domain_state' config flag is set (like with any IP4v configuration
states) using this style:
! [my_domain] dynamic IP config: malformed (interface 10.0.2.1/24 ...)
Fixes#4242
The NIC router DHCP server used to add an extra option 6 field to DHCP replies
for each DNS server address. This conflicts with RFC #2132 section 3.8 which
states that the addresses should be listed within one option 6 field without
delimiter. The discrepancy is fixed by this commit.
Ref #4242
File size must be the same as the number of bytes that can be read from
the file. Otherwise, this will trigger a `Truncated_during_read`
exception.
Fixesgenodelabs/genode#4240
Via a new configuration attribute, the user can decide whether the router
should answer dropped fragmented IPv4 with an ICMP "destination unreachable"
packet and, if so, which value the ICMP code field of this packet should have.
The default is that the router doesn't send such responses (silently dropping
fragmented IPv4). The behavior is tested by the 'nic_router_ipv4_fragm' test.
Fixes#4236
If the new attribute 'dropped_fragm_ipv4' of the <report> tag in the NIC router
config is set "yes", the router will report the number of packets that were
dropped per interface respectively domain because fragmented IPv4 is not
supported. The default is not to report the counter. The behavior is tested by
the 'nic_router_ipv4_fragm' test.
Ref #4236
The NIC router used to ignore the IPv4 header fields "More fragments" and
"Fragment offset" completely. Therefore higher-level protocols of fragmented
IPv4 were interpreted wrong because each fragment was considered a self-
standing packet, expecting, for instance UDP/TCP headers somewhere inside of
the UDP/TCP data field. Normally, such packets were dropped as soon as the
UDP/TCP checksum check failed because of the misinterpretation. However,
it was also possible for fragmented IPv4 to pass the router although normally
only partially.
IPv4 fragmentation support in the router would introduce some potential
security risks and is presumably not an easy endeavor. So, for now, we settled
on not supporting IPv4 fragmentation. With this commit, the router simply drops
all fragmented IPv4. This is reflected to the log for each fragment as "drop
packet (fragmented IPv4 not supported)" when 'verbose_packet_drop="yes"' is
configured.
The new test 'run/nic_router_ipv4_fragm' is an automated test for this
behavior. The test is added to the autopilot list.
Ref #4236
- remove redundant file system factory
- remove dead code block
The code was guarded by preprocessor directives checking whether the
contrib code define "_USE_MKFS" is 1. As "_USE_MKFS" is not set one
for our port of FAT, the code was never executed and can be removed.
- remove uneffective config attributes
Apparently, the former XML attributes to the plugin 'drive' and
'codepage' had no effect. I tested them in a scenario with the VFS
block server on a disk-image boot-module as back end. Regardless of
the 'drive' value, the block session label was always "0". Regardless
of the 'codepage' value, the FAT on the disk image succeeded to mount
when not using '--codepage' for 'mkfs.fat' and failed to mount when
using '--codepage' to specify a supported but foreign codepage for
'mkfs.fat' (e.g. "720").
Ref #4220
There was one global static constructor:
! namespace Fatfs { static Constructible<Platform> _platform; }
This caused applications that used the lib or the <fatfs> VFS plugin to end up
in an uncaught exception due to Genode::Component complaining that method
'construct' returned without executing pending static constructors if they
didn't call Genode::Env::exec_static_constructors().
As the use of Genode::Env::exec_static_constructors() is discouraged in Genode,
this commit rather moves the '_platform' object to the scope of the
initializing function and introduces a global static pointer to the object that
gets set by the initializing function. Although this prevents the exception, it
is, technically speaking even worse than the former solution as the new pointer
isn't checked for validity in contrast to the 'Constructible' object.
However, so far, I don't see a clean solution to this problem without the need
for Genode::Env::exec_static_constructors().
Fixes#4220
* the GPU multiplexer now offers the platform service to the Intel
framebuffer driver (driver_manager)
* ajdusted drivers_managed-pc to hand out resources to the GPU driver
* adjust quotas
issue #4233
The platform services is intented to be used by dde_linux's intel_fb_drv
in order to initlialize displays.
* implement and announce platform session
* limit accessible GTT and aperture of client to 64 MB
* forward display engine IRQs to platform client
* move all PCI resources to 'Igd::Resources' class in order to make them
accessible by the platform service and the GPU driver
* fix fence register allocation for id zero (return true)
issue #4233
For mesa-21 the client takes care and manages
the virtual address space of the vGPU by itself and the intel/gpu driver
can't add silently a guard page anymore. Move the patch to the drm/ioctl
of the former mesa version.
Issue #4148#4233
_unmap_dataspace_ggtt requires the cap of Ggtt::Mapping (ring_map, ctx_map)
in order to find the right metadata and to free up the ggtt entries. Also the
pte range is removed already if the metadata was found.
Issue #4148#4233
BREAKS CONFIG COMPATIBILITY:
This commit changes the configuration interface of the NIC router in a way that
may break systems that use the component without proper adjustment!
HOW TO ADJUST:
At each occurrence of the '<uplink ...>' tag in a NIC router configuration
replace the tag name 'uplink' with 'nic-client'. The rest of the tag stays the
same.
The term "uplink" for network interfaces in the router that have a NIC session
client as back end was introduced in a time when Uplink sessions didn't yet
exist. Now, they do and, although both an uplink and an Uplink session
normally describe a network session between router and network device driver,
they are based on two different service types (NIC and Uplink). This can easily
cause confusion when integrating the router (the <uplink> is not related to
Uplink sessions) or trying to understand its functioning (an 'Uplink' object
has nothing to do with the Uplink service).
Therefore, this commit introduces the more specific term "NIC client" for an
interface that is based on a NIC session requested by the router. This doesn't
imply any semantic changes at the NIC router. However, the commit also brings a
broader update of the router's README and removes the term "downlink" that was
used only in documentation to refer to interfaces backed by a NIC session
provided by the router. The term was only associated with this meaning because
it is the natural counterpart to an uplink. This isn't appropriate anymore as
the terms for interface types have moved to a more technical level.
The commit adjusts all scenarios in the basic Genode repositories properly.
Fixes#4238
An interface that received a signal for a link-state change accessed its
domain reference without assuming that it could not be attached to a domain
at that moment. This caused the NIC router to crash with an uncaught exception
of type 'Net::Pointer<Net::Domain>::Invalid'. The commit adds a catch
directive for this exception resulting in the handler doing nothing if not
attached to any domain.
Fixes#4222
The test script failed during preparation of the on-target execution for
USB Armory with the following error:
! can't read "tz_vmm_block_irq": no such variable
Presumably, the script wasn't run anymore since the introduction of the
'tz_vmm_block_irq' variable for i.MX53 QSB. As we do not have infrastructure
for automated testing of the USB Armory and there seems to be not much
interest in using Genode on this platform, this commit simply removes the
support from the script.
Filtering boards in a run script by specs isn't the right way anymore (the
specs do not exist anymore). Nowadays, we have to use [have_board] instead.
Ref #4229
For unknown reasons, the former 'wget genode.org' call, that was meant to test
network in the Trustzone guest on imx53_qsb_tz, didn't succeed anymore although
the same call succeeded on my Sculpt VM Linux. However, 'ping 1.1.1.1' still
works, so, the script now uses this as test for networking instead.
Fixes#4229
So far, in order to create an ARP reply, the NIC router merely created a copy
of the corresponding ARP request and modified only those values that differ.
This approach has the disadvantage of re-using bad parameters from a broken
request. The specific use-case that made this visible was an early version of
the Pine board network driver that used to forward ARP requests with a greater
size than required. The ARP replies of the router re-used this size and
confused other network nodes with that. In general, the NIC router should
rely on the data of incoming packets the least possible. Therefore, with this
commit, the router creates a new ARP reply from scratch and uses only those
values required from the corresponding ARP request.
Fixes#4235