4.4 KiB
Flow Hospital
Overview
The flow hospital refers to a built-in node service that manages flows that have encountered an error.
This service is responsible for recording, tracking, diagnosing, recovering and retrying flows. It determines whether errored flows should be retried from their previous checkpoints or have their errors propagate. Flows may be recoverable under certain scenarios (eg. manual intervention may be required to install a missing contract JAR version). For a given errored flow, the flow hospital service determines the next course of action towards recovery and retry.
Note
If the raised exception cannot be handled from the hospital, it will be propagated to the application code. If the exception is not handled by the application code either, then the flow will terminate and any records of it will be removed from the hospital. Below, you can find a list of the errors that are handled by the hospital.
This concept is analogous to exception management handling associated with enterprise workflow software, or retry queues/stores in enterprise messaging middleware for recovering from failure to deliver a message.
Functionality
Flow hospital functionality is enabled by default in . No explicit configuration settings are required.
There are two aspects to the flow hospital:
- run-time behaviour in the node upon failure, including retry and recovery transitions and policies.
- visualisation of failed flows in the Explorer UI.
Run-time behaviour
Specifically, there are two main ways a flow is hospitalized:
A counterparty invokes a flow on your node that isn’t installed (i.e. missing CorDapp): this will cause the flow session initialisation mechanism to trigger a
ClassNotFoundException
. If this happens, the session initiation attempt is kept in the hospital for observation and will retry if you restart the node. Corrective action requires installing the correct CorDapp in the node's "cordapps" directory.Warning
There is currently no retry API. If you don’t want to install the cordapp, you should be able to call killFlow with the UUID associated with the failing flow in the node's log messages.
Once started, if a flow experiences an error, the following failure scenarios are handled:
SQLException
mentioning a deadlock: If this happens, the flow will retry. If it retries more than once, a back off delay is applied to try and reduce contention. Current policy means these types of failed flows will retry forever (unless explicitly killed). No intervention required.- Database constraint violation (
ConstraintViolationException
): This scenario may occur due to natural contention between racing flows as Corda delegates handling using the database's optimistic concurrency control. As the likelihood of re-occurrence should be low, the flow will actually error and fail if it experiences this at the same point more than 3 times. No intervention required. - Finality Flow handling - Corda 3.x (old style)
FinalityFlow
and Corda 4.xReceiveFinalityFlow
handling: If on the receive side of the finality flow, any error will result in the flow being kept in for observation to allow the cause of the error to be rectified (so that the transaction isn’t lost if, for example, associated contract JARs are missing). Intervention is expected to be “rectify error, perhaps uploading attachment, and restart node” (or alternatively reject and call killFlow). FlowTimeoutException
: This is used internally by the notary client flow when talking to an HA notary. It’s used to cause the client to try and talk to a different member of the notary cluster if it doesn't hear back from the original member it sent the request to within a “reasonable” time. The time is hard to document as the notary members, if actually alive, will inform the requester of the ETA of a response. This can occur an infinite number of times. i.e. we never give up notarising. No intervention required.SQLTransientConnectionException
: Database connection pooling errors are dealt with. If this exception occurs, the flow will retry. After retrying a number of times, the errored flow is kept in for observation.
Note
Flows that are kept in for observation are retried upon node restart.