because there are still quite a few links to the old name and URL even
within our own repository.
Reformat docsite slightly to make the white papers more prominent.
Also link to the Chinese/Japanese translations of the old paper.
Make the build script do both platform/intro and tech white papers.
* Add discussion of state pointers and the tokens SDK.
Fix ugly hyperlink boxes.
Comment out "market infrastructure" section for now as it was never implemented. It will come back in a later PR that creates a "future work" section.
* Address review comments.
Tech white paper refresh, part 1.
In part 1:
* A new section is added on package namespace ownership and the no-overlap rule.
* The spelling of "serialize" is standardized on the US spelling used by the code, and add some content on serialization to the docs.
* Make a variety of smaller edits intended to make it read better.
* Spelling fixes.
* The discussion of C-I is temporarily removed, pending later re-addition in a new privacy section.
* Reference states are described.
* More TODOs are added to help me keep track of things that are needed.
* The discussion of time and clock sync is updated.
* The discussion of identity lookups is removed.
- Handle errors in Jackson and checkpoint deserialisation. A file
notifying the user that the checkpoint dump failed is created when
errors occur.
- Handle message deserialisation errors. A string placeholder is used
if an error occurs.
- Add more information about subflows (include their `FlowLogic`)
- Increase clarity in checkpoint output field names
* CORDA-3904 Add `flowCallStackSummary`
Add `flowCallStackSummary` to the output which contains the same content
as `flowCallStack` minus each subflow's `FlowLogic`. The `FlowLogic`
contains a ton of info which is normally repeated in each subflow.
Adding the summary gives an overview of the steps the flow executed
and which step it is currently on.
The `suspendedOn` field is put underneath the summary and the original
call stack is moved below the suspended info.
This puts the most useful information towards the top of the json file.
* CORDA-2617: Add failover listeners to terminate node process
This is a backport of changes done in Corda Enterprise.
It will be triggered in case of:
a) Loss of connectivity to in-built Artemis for Bridge Control;
b) Loss of connectivity to in-built Artemis for P2P connectivity.
Note on merge to CE: Disregard these changes and take whatever CE already has.
* CORDA-2617: Update documentation on stability of Corda Node
* CORDA-2617: Documentation update after discussion with @mnesbit