User has fixed the HA pair storage redundancy issue:
- netinfra-01 moved to S2 (tsys5), netinfra-02 stays on D2 (tsys4)
- ucs-02 moved to S2 (tsys5), ucs-01 stays on D2 (tsys4)
Both pairs now survive any single storage server failure. Marked as
FIXED in Known Issues.

Revised audit includes:
- Corrected VM placements from fresh qm config data
- Host capacity analysis: tsys1 (118% RAM), tsys5 (135% RAM), tsys9
  (131% RAM) are overcommitted; tsys6 (38%) and tsys7 (30%) have room
- Wnode storage rebalancing plan: move wnode-tsys6 → S4, wnode-tsys7 →
  S1, giving every wnode its own physical disk
- Friday maintenance plan: tsys2 Proxmox install as primary deliverable,
  VM migrations to relieve overloaded hosts, USB-passthrough VMs relocate
  from tsys1 to tsys9
- Cnode quorum: documented as fundamental constraint (3 cnodes, 2 NFS
  servers), accepted for now, revisit post-Friday when local-SSD boot
  becomes available