The cross-rack trunk (ch1, 4×1G) between core-sw01 and tor3-stor is
still static mode=on — no failure detection if a cable dies. Adding
command files to convert both switches to LACP during Friday's
maintenance window. Core hash stays layer-2-3 (5448 hardware limit);
stor hash stays layer-2-3-4 (already set).
💘 Generated with Crush
Assisted-by: Crush:glm-5.2
26 lines
922 B
Plaintext
26 lines
922 B
Plaintext
! #369/#394: Convert cross-rack trunk ch1 from static (mode=on) to LACP
|
|
! Switch: core-sw01 (Dell PowerConnect 5448, rack 5)
|
|
! WHEN: Friday maintenance window — BOTH switches must change together
|
|
! RISK: Brief storage-net outage during transition (seconds)
|
|
!
|
|
! Current: g13-g16 in ch1, mode=on (static, no failure detection)
|
|
! Target: g13-g16 in ch1, mode=auto (LACP active partner negotiation)
|
|
!
|
|
! NOTE: core-sw01 hash stays layer-2-3 (hardware limit — best available)
|
|
! tor3-stor hash stays layer-2-3-4 (already set)
|
|
!
|
|
! IMPORTANT: Run this SIMULTANEOUSLY with tor3-stor change.
|
|
! If one side is LACP and other is static, trunk goes down until
|
|
! both sides match. Plan for ~30s storage-net outage.
|
|
!
|
|
enable
|
|
configure
|
|
interface range ethernet g13-g16
|
|
no channel-group
|
|
channel-group 1 mode auto
|
|
exit
|
|
exit
|
|
show interfaces status port-channel 1
|
|
show lacp port-channel 1
|
|
copy running-config startup-config
|