# TODO.md — Pending User Actions **Date:** 2026-07-27 **Items needing user input or physical action.** --- ## 1. tsys2 Windows hardware inventory (run on the Windows host) pfv-tsys2 is currently Windows 10. Before rebuilding it as Proxmox, gather hardware data so the architecture plan can account for it. ### Option A: PowerShell (recommended — single command, copy-paste output) Open **PowerShell as Administrator** and run: ```powershell # Full hardware inventory in one shot Write-Output "=== COMPUTER ===" Get-CimInstance Win32_ComputerSystem | Select-Object Manufacturer, Model, SystemType, TotalPhysicalMemory | Format-List Write-Output "`n=== CPU ===" Get-CimInstance Win32_Processor | Select-Object Name, NumberOfCores, NumberOfLogicalProcessors, MaxClockSpeed | Format-List Write-Output "`n=== MEMORY STICKS ===" Get-CimInstance Win32_PhysicalMemory | Select-Object Manufacturer, PartNumber, Capacity, Speed, ConfiguredClockSpeed, DeviceLocator, FormFactor | Format-Table -AutoSize Write-Output "`n=== DISKS ===" Get-PhysicalDisk | Select-Object FriendlyName, MediaType, BusType, Size, SpindleSpeed | Format-Table -AutoSize Write-Output "`n=== DISK PARTITIONS ===" Get-Disk | Select-Object Number, FriendlyName, Size, PartitionStyle, OperationalStatus | Format-Table -AutoSize Write-Output "`n=== NETWORK ADAPTERS ===" Get-NetAdapter | Select-Object Name, InterfaceDescription, Status, LinkSpeed, MacAddress | Format-Table -AutoSize Write-Output "`n=== GPU(s) ===" Get-CimInstance Win32_VideoController | Select-Object Name, AdapterRAM, DriverVersion, VideoProcessor | Format-List Write-Output "`n=== PCIe SLOTS ===" Get-CimInstance Win32_SystemSlot | Select-Object SlotDesignation, CurrentUsage, Status | Format-Table -AutoSize Write-Output "`n=== USB DEVICES (storage + network only) ===" Get-PnpDevice -PresentOnly | Where-Object { $_.Class -in @('DiskDrive','Net','USB') } | Select-Object Class, FriendlyName, Status | Format-Table -AutoSize ``` Copy the full output into a file (e.g., `tsys2-hardware.txt`) or paste it directly into the chat. ### Option B: Command Prompt (cmd.exe) fallbacks If PowerShell is unavailable for some reason, these cmd commands give a subset: ```cmd :: Computer model and serial wmic computersystem get manufacturer,model wmic bios get serialnumber :: CPU wmic cpu get name,numberofcores,numberoflogicalprocessors,maxclockspeed :: RAM (total) wmic computersystem get totalphysicalmemory :: RAM sticks (per-slot detail) wmic memorychip get manufacturer,capacity,speed,partnumber,devicelocator :: Disks wmic diskdrive get model,size,interfacetype,mediatype :: Network adapters wmic nic where netenabled=true get name,speed,macaddress :: GPU wmic path win32_videocontroller get name,adapterram,driverversion ``` ### What I'm looking for - **Disk inventory**: Are there any SSDs/NVMe available locally? (Determines whether wnode-tsys2 can use local storage like the other wnodes.) - **Network adapters**: How many onboard NICs? Model? (Determines whether tsys2 needs a USB dongle for storage network like tsys4/9, or has a real onboard NIC available.) - **RAM layout**: Is all 32 GB in 1 stick, 2 sticks, or 4 sticks? (Affects memory bandwidth for HPC workloads — dual-channel matters.) - **GPU detail**: Confirm the Quadro M1200 model and VRAM for passthrough planning. - **PCIe slots**: Is there a free PCIe slot for adding a NIC or HBA? - **Service tag confirmation**: `GH1XZG2` (already on file from spreadsheet). --- ## 2. Friday maintenance window (physical hardware) ### tsys4 — install PCIe NIC + add RAM 1. Power down tsys4 (graceful shutdown via Proxmox UI or `shutdown -h now`). 2. Install the **PCIe NIC** (Intel i350-T2 or similar 1 GbE dual-port). 3. Add **RAM**: 16 GB → 64 GB DDR3 ECC. 4. Power on, then update `/etc/network/interfaces` to replace `enx8cae4ccda926` (USB dongle) with the new PCIe NIC device name. 5. Reboot to activate new NIC and NFS nconnect. 6. Run `validate-fixes.sh pfv-tsys4` to confirm. ### tsys5 — plug storage cable + install NVMe 1. Plug the **second ethernet cable** into tsys5's dedicated storage NIC. 2. Verify bond0 recovery: `cat /proc/net/bonding/bond0` — look for "Number of ports: 2" and a real partner MAC (not all zeros). 3. Apply bond hash fix (same as tsys6/7): ```bash echo "layer3+4" > /sys/class/net/bond0/bonding/xmit_hash_policy ``` 4. Install the **PCI NVMe drive**. 5. Format NVMe as local directory storage (see TODO section 3 below). 6. Reboot tsys5 to activate NFS nconnect. 7. Run `validate-fixes.sh pfv-tsys5` to confirm. --- ## 3. tsys5 NVMe format/mount decision (after Friday install) **Recommendation: local-only, not NFS-exported.** Format as Proxmox directory storage so it shows up as a VM image target in the Proxmox UI. After the NVMe is physically installed and visible in Proxmox: 1. Identify the device: `lsblk` or `ls /dev/nvme*` 2. Format and add to Proxmox: ```bash # Option A: LVM-thin (thin provisioning, snapshots) pvcreate /dev/nvme0n1 vgcreate nvme-pool /dev/nvme0n1 lvcreate -l 100%FREE -T nvme-pool/data # Then in Proxmox UI: Datacenter > Storage > Add > LVM-Thin # ID: nvme-local # Volume Group: nvme-pool # Thin Pool: data # Content: Disk image, Container template # Option B: Directory (simpler, no thin provisioning) mkfs.ext4 /dev/nvme0n1 mkdir -p /mnt/nvme mount /dev/nvme0n1 /mnt/nvme # Add to /etc/fstab for persistence # Then in Proxmox UI: Datacenter > Storage > Add > Directory # ID: nvme-local # Directory: /mnt/nvme # Content: Disk image, Container template ``` 3. Use for wnode-tsys5 boot disk (highest impact) and sectestbed VM scratch. --- ## 4. Post-hardware validation (run after Friday work) 1. Re-run iperf matrix: `./iperf-full-matrix.sh` 2. Validate tsys4 and tsys5: `./validate-fixes.sh pfv-tsys4 && ./validate-fixes.sh pfv-tsys5` 3. Update PROJECT.md with post-hardware iperf numbers. --- ## 5. Open questions for next session - Are the hosts a Proxmox cluster (`pvecm status`) or standalone installs? Determines whether live migration is available. - What k8s distribution is in use? (k3s, kubeadm, RKE2?) - Container runtime? (containerd, cri-o?) - Is there a local container image registry mirror? - What specific ETL tools? (GDAL, PostGIS, xarray, Dask?) - HPC job scheduler? (plain k8s Jobs, Argo Workflows, Volcano?) - What uses tsys5's SDR + parallel port before planning tsys5 role changes? - tsys3 thermal state (laptop in rack for years) — check `sensors`.