Daniel González Cabanelas ddf9bea738 mvebu: LS421DE: fix low performance issue
The Buffalo Linkstation LS421DE isn't able to enable the Level 2 cache
(AKA Aurora cache). As of result of this, the throughput is about half of
the expected, e.g when doing network data transfers.

Fix it by adding the broken-idle property in the coherency fabric node.

Signed-off-by: Daniel González Cabanelas <dgcbueu@gmail.com>
Signed-off-by: maurerr <mariusd84@gmail.com>
2021-09-01 08:07:22 +00:00
..
2020-06-03 20:34:14 +02:00