openwrt/target/linux/mediatek/patches-6.1/805-v6.2-thermal-drivers-mtk-use-function-pointer-for-raw_to_.patch
Daniel Golle d85438f454 mediatek: copy patches and files for Linux 6.1
First step only copies patches-5.15 and files-5.15 to
patches-6.1 and files-6.1 respectively.

Signed-off-by: Daniel Golle <daniel@makrotopia.org>
2023-07-07 14:01:39 +02:00

57 lines
1.9 KiB
Diff

From 69c17529e8418da3eec703dde31e1b01e5b0f7e8 Mon Sep 17 00:00:00 2001
From: Daniel Golle <daniel@makrotopia.org>
Date: Wed, 18 Jan 2023 02:48:41 +0000
Subject: [PATCH 1/2] thermal/drivers/mtk: use function pointer for
raw_to_mcelsius
Instead of having if-else logic selecting either raw_to_mcelsius_v1 or
raw_to_mcelsius_v2 in mtk_thermal_bank_temperature introduce a function
pointer raw_to_mcelsius to struct mtk_thermal which is initialized in the
probe function.
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
---
drivers/thermal/mtk_thermal.c | 17 ++++++++++-------
1 file changed, 10 insertions(+), 7 deletions(-)
--- a/drivers/thermal/mtk_thermal.c
+++ b/drivers/thermal/mtk_thermal.c
@@ -292,6 +292,8 @@ struct mtk_thermal {
const struct mtk_thermal_data *conf;
struct mtk_thermal_bank banks[MAX_NUM_ZONES];
+
+ int (*raw_to_mcelsius)(struct mtk_thermal *mt, int sensno, s32 raw);
};
/* MT8183 thermal sensor data */
@@ -656,13 +658,9 @@ static int mtk_thermal_bank_temperature(
for (i = 0; i < conf->bank_data[bank->id].num_sensors; i++) {
raw = readl(mt->thermal_base + conf->msr[i]);
- if (mt->conf->version == MTK_THERMAL_V1) {
- temp = raw_to_mcelsius_v1(
- mt, conf->bank_data[bank->id].sensors[i], raw);
- } else {
- temp = raw_to_mcelsius_v2(
- mt, conf->bank_data[bank->id].sensors[i], raw);
- }
+ temp = mt->raw_to_mcelsius(
+ mt, conf->bank_data[bank->id].sensors[i], raw);
+
/*
* The first read of a sensor often contains very high bogus
@@ -1085,6 +1083,11 @@ static int mtk_thermal_probe(struct plat
mtk_thermal_release_periodic_ts(mt, auxadc_base);
}
+ if (mt->conf->version == MTK_THERMAL_V1)
+ mt->raw_to_mcelsius = raw_to_mcelsius_v1;
+ else
+ mt->raw_to_mcelsius = raw_to_mcelsius_v2;
+
for (ctrl_id = 0; ctrl_id < mt->conf->num_controller ; ctrl_id++)
for (i = 0; i < mt->conf->num_banks; i++)
mtk_thermal_init_bank(mt, i, apmixed_phys_base,