From 681b652c9dfc4037d4a55b2733e091a4e1a5de18 Mon Sep 17 00:00:00 2001
|
|
From: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>
|
|
Date: Wed, 19 Apr 2023 08:11:46 +0200
|
|
Subject: [PATCH 17/42] thermal/drivers/mediatek: Add temperature constraints
|
|
to validate read
|
|
MIME-Version: 1.0
|
|
Content-Type: text/plain; charset=UTF-8
|
|
Content-Transfer-Encoding: 8bit
|
|
|
|
The AUXADC thermal v1 allows reading temperature range between -20°C to
|
|
150°C and any value out of this range is invalid.
|
|
|
|
Add new definitions for MT8173_TEMP_{MIN_MAX} and a new small helper
|
|
mtk_thermal_temp_is_valid() to check if new readings are in range: if
|
|
not, we tell to the API that the reading is invalid by returning
|
|
THERMAL_TEMP_INVALID.
|
|
|
|
It was chosen to introduce the helper function because, even though this
|
|
temperature range is realistically ok for all, it comes from a downstream
|
|
kernel driver for version 1, but here we also support v2 and v3 which may
|
|
may have wider constraints.
|
|
|
|
Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>
|
|
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
|
|
Link: https://lore.kernel.org/r/20230419061146.22246-3-angelogioacchino.delregno@collabora.com
|
|
---
|
|
drivers/thermal/mediatek/auxadc_thermal.c | 24 +++++++++++++++++------
|
|
1 file changed, 18 insertions(+), 6 deletions(-)
|
|
|
|
--- a/drivers/thermal/mediatek/auxadc_thermal.c
|
|
+++ b/drivers/thermal/mediatek/auxadc_thermal.c
|
|
@@ -116,6 +116,10 @@
|
|
/* The calibration coefficient of sensor */
|
|
#define MT8173_CALIBRATION 165
|
|
|
|
+/* Valid temperatures range */
|
|
+#define MT8173_TEMP_MIN -20000
|
|
+#define MT8173_TEMP_MAX 150000
|
|
+
|
|
/*
|
|
* Layout of the fuses providing the calibration data
|
|
* These macros could be used for MT8183, MT8173, MT2701, and MT2712.
|
|
@@ -689,6 +693,11 @@ static const struct mtk_thermal_data mt7
|
|
.version = MTK_THERMAL_V3,
|
|
};
|
|
|
|
+static bool mtk_thermal_temp_is_valid(int temp)
|
|
+{
|
|
+ return (temp >= MT8173_TEMP_MIN) && (temp <= MT8173_TEMP_MAX);
|
|
+}
|
|
+
|
|
/**
|
|
* raw_to_mcelsius_v1 - convert a raw ADC value to mcelsius
|
|
* @mt: The thermal controller
|
|
@@ -815,14 +824,17 @@ static int mtk_thermal_bank_temperature(
|
|
temp = mt->raw_to_mcelsius(
|
|
mt, conf->bank_data[bank->id].sensors[i], raw);
|
|
|
|
-
|
|
/*
|
|
- * The first read of a sensor often contains very high bogus
|
|
- * temperature value. Filter these out so that the system does
|
|
- * not immediately shut down.
|
|
+ * Depending on the filt/sen intervals and ADC polling time,
|
|
+ * we may need up to 60 milliseconds after initialization: this
|
|
+ * will result in the first reading containing an out of range
|
|
+ * temperature value.
|
|
+ * Validate the reading to both address the aforementioned issue
|
|
+ * and to eventually avoid bogus readings during runtime in the
|
|
+ * event that the AUXADC gets unstable due to high EMI, etc.
|
|
*/
|
|
- if (temp > 200000)
|
|
- temp = 0;
|
|
+ if (!mtk_thermal_temp_is_valid(temp))
|
|
+ temp = THERMAL_TEMP_INVALID;
|
|
|
|
if (temp > max)
|
|