openwrt/target/linux/kirkwood/base-files/etc/init.d/hwmon_fancontrol
Thomas Beckler 450ec48d61 kirkwood: use 3 temperature sensors for Zyxel NSA310B
Instead of taking the input of one temperature sensor (temp1), the
script takes into account three temperature sensors to control the
PWM of the cooling fan.

temp1 -> placed on main board
temp2 -> placed on main board
temp3 -> placed on or close to chipset

All three temperatures give valid input for the PWM of the fan on
NSA310 and are actually changing.

Tested on two NSA310.

Signed-off-by: Thomas Beckler <thomas.beckler@hotmail.com>
Reviewed-by: Alberto Bursi <bobafetthotmail@gmail.com>
[commit title/message facelift, code cleanup]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-02-05 22:21:08 +01:00

49 lines
2.0 KiB
Bash
Executable File

#!/bin/sh /etc/rc.common
START=98
boot() {
# configuring (lm85/lm63) onboard temp/fan controller to run the fan on its own
# for more information, please read https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface
case $(board_name) in
iom,ix2-200)
path_to_hwmon='/sys/class/hwmon/hwmon0'
echo 2 > "$path_to_hwmon/pwm1_enable" # fan is on pwm1
;;
seagate,blackarmor-nas220)
path_to_hwmon='/sys/devices/platform/ocp@f1000000/f1011000.i2c/i2c-0/0-002e/hwmon/hwmon0'
# adt7476 fan control chip. 3 temp sensors. Set to 1/4 speed at 35C and max speed at 48C.
echo 7 > "$path_to_hwmon/pwm1_auto_channels_temp"
echo 64 > "$path_to_hwmon/pwm1_auto_point1_pwm"
echo 255 > "$path_to_hwmon/pwm1_auto_point2_pwm"
echo 35000 > "$path_to_hwmon/temp1_auto_point1_temp"
echo 48000 > "$path_to_hwmon/temp1_auto_point2_temp"
echo 35000 > "$path_to_hwmon/temp2_auto_point1_temp"
echo 48000 > "$path_to_hwmon/temp2_auto_point2_temp"
echo 35000 > "$path_to_hwmon/temp3_auto_point1_temp"
echo 48000 > "$path_to_hwmon/temp3_auto_point2_temp"
echo 2 > "$path_to_hwmon/pwm1_enable"
;;
zyxel,nsa310b)
path_to_hwmon='/sys/devices/platform/ocp@f1000000/f1011000.i2c/i2c-0/0-002e/hwmon/hwmon0'
# use the max. value of (temp1) OR (temp2) OR (temp3) as an input
# for the PWM of the cooling fan
echo 123 > "$path_to_hwmon/pwm1_auto_channels"
# Temperature sensor #1 placed on mainboard
echo 30000 > "$path_to_hwmon/temp1_auto_temp_min"
echo 49600 > "$path_to_hwmon/temp1_auto_temp_max"
# Temperature sensor #2 placed on mainboard
# range: 0 to 127000 in steps of 1000 [millicelsius]
echo 30000 > "$path_to_hwmon/temp2_auto_temp_min"
# range: 0 to 127000 in steps of ???? [millicelsius]
echo 49600 > "$path_to_hwmon/temp2_auto_temp_max"
# Temperature sensor #3 placed close to a chipset
# range: 0 to 60000 in steps of 1000 [millicelsius]
echo 23000 > "$path_to_hwmon/temp3_auto_temp_min"
# pre-defined steps: 103000, 122000, 143300, 170000 in [millicelsius]
echo 103000 > "$path_to_hwmon/temp3_auto_temp_max"
;;
esac
}