openwrt/target/linux/bcm27xx/patches-5.10/950-0716-drm-gud-Add-async_flush-module-parameter.patch
Álvaro Fernández Rojas 8299d1f057 bcm27xx: add kernel 5.10 support
Rebased RPi foundation patches on linux 5.10.59, removed applied and reverted
patches, wireless patches and defconfig patches.

bcm2708: boot tested on RPi B+ v1.2
bcm2709: boot tested on RPi 4B v1.1 4G
bcm2711: boot tested on RPi 4B v1.1 4G

Signed-off-by: Álvaro Fernández Rojas <noltari@gmail.com>
2021-08-21 19:07:07 +02:00

56 lines
2.2 KiB
Diff

From e0eb7ca2dd07ca8878b67cc20e75f9d7e46d80f4 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?Noralf=20Tr=C3=B8nnes?= <noralf@tronnes.org>
Date: Sat, 3 Jul 2021 16:13:21 +0200
Subject: [PATCH] drm/gud: Add async_flush module parameter
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: 8bit
[ drm-misc commit a0356899ebe8ecde0da9c5685cc47154db973a5e ]
Provide a way for userspace to choose synchronous flushing/pageflips.
This helps save CPU and power.
It is also useful for test scripts since userspace can know when a flush
has happended and wait before doing the next visual test.
Cc: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Noralf Trønnes <noralf@tronnes.org>
Reviewed-by: Peter Stuge <peter@stuge.se>
Link: https://patchwork.freedesktop.org/patch/msgid/20210703141321.35494-2-noralf@tronnes.org
---
drivers/gpu/drm/gud/gud_pipe.c | 15 +++++++++++++++
1 file changed, 15 insertions(+)
--- a/drivers/gpu/drm/gud/gud_pipe.c
+++ b/drivers/gpu/drm/gud/gud_pipe.c
@@ -24,6 +24,19 @@
#include "gud_internal.h"
/*
+ * Some userspace rendering loops runs all displays in the same loop.
+ * This means that a fast display will have to wait for a slow one.
+ * For this reason gud does flushing asynchronous by default.
+ * The down side is that in e.g. a single display setup userspace thinks
+ * the display is insanely fast since the driver reports back immediately
+ * that the flush/pageflip is done. This wastes CPU and power.
+ * Such users might want to set this module parameter to false.
+ */
+static bool gud_async_flush = true;
+module_param_named(async_flush, gud_async_flush, bool, 0644);
+MODULE_PARM_DESC(async_flush, "Enable asynchronous flushing [default=true]");
+
+/*
* FIXME: The driver is probably broken on Big Endian machines.
* See discussion:
* https://lore.kernel.org/dri-devel/CAKb7UvihLX0hgBOP3VBG7O+atwZcUVCPVuBdfmDMpg0NjXe-cQ@mail.gmail.com/
@@ -577,6 +590,8 @@ void gud_pipe_update(struct drm_simple_d
if (gdrm->flags & GUD_DISPLAY_FLAG_FULL_UPDATE)
drm_rect_init(&damage, 0, 0, fb->width, fb->height);
gud_fb_queue_damage(gdrm, fb, &damage);
+ if (!gud_async_flush)
+ flush_work(&gdrm->work);
}
if (!crtc->state->enable)