Drop custom 'mtd-cal-data' and switch to 'nvmem-cells' based solution
for fetching radio calibration data and its MAC address.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
All the QCA9531 based boards from ALFA Network are based on the same
design and share a common DTSI: 'qca9531_alfa-network_r36a.dtsi'.
Instead of defining 'nvmem-cells' for the MAC address in every device's
DTS, move definition to the common DTSI file.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
The uart node is enabled on all devices except one (GL-USB150 *).
Thus, let's not have a few hundred nodes to enable it, but do not
disable it in the first place.
Where the majority of devices is using it, also move the serial0
alias to the DTSI.
*) Since GL-USB150 even defines serial0 alias, the missing uart
is probably just a mistake. Anyway, disable it for now so this
patch stays cosmetic.
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
None of the spi drivers on ath79 uses the num-cs property.
Cc: Chuanhong Guo <gch981213@gmail.com>
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Acked-by: Chuanhong Guo <gch981213@gmail.com>
ALFA Network N2Q is an outdoor N300 AP/CPE based on Qualcomm/Atheros
QCA9531 v2. This model is a successor of the old N2 which was based
on Atheros AR7240. FCC ID: 2AB8795311.
Specifications:
- Qualcomm/Atheros QCA9531 v2
- 650/400/200 MHz (CPU/DDR/AHB)
- 128 MB of RAM (DDR2)
- 16 MB of flash (SPI NOR)
- 2T2R 2.4 GHz Wi-Fi with ext. PA (Skyworks SE2623L) and LNA
- 2x 10/100 Mbps Ethernet with passive PoE input in one port (24 V)
- PoE pass through in second port (controlled by GPIO)
- support for optional 802.3af/at PoE module
- 1x mini PCIe slot (PCIe bus, extra 4.2 V for high power cards)
- 2x IPEX/U.FL connectors on PCB
- 1x USB 2.0 mini Type-B (power controlled by GPIO)
- 8x LED (7 of them are driven by GPIO)
- 1x button (reset)
- external h/w watchdog (EM6324QYSP5B, enabled by default)
- UART (4-pin, 2.54 mm pitch) header on PCB
- LEDs (2x 5-pin, 2.54 mm pitch) header on PCB
Flash instruction:
You can use sysupgrade image directly in vendor firmware which is based
on LEDE/OpenWrt. Alternatively, you can use web recovery mode in U-Boot:
1. Configure PC with static IP 192.168.1.2/24.
2. Connect PC with one of RJ45 ports, press the reset button, power up
device, wait for first blink of all LEDs (indicates network setup),
then keep button for 3 following blinks and release it.
3. Open 192.168.1.1 address in your browser and upload sysupgrade image.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>