This patch adds support for the Netgear WN3100RPv2
http://www.netgear.com/support/product/wn3100rpv2.aspx
Specifications:
- SoC: MediaTek MT7620A (580MHz, ramips)
- RAM: 32MB DDR
- Storage: 8MB NOR SPI flash
- Wireless: builtin MT7620A, 2x2:2 with u.FL connectors
- Ethernet: 1x100M
- Stock firmware based on OpenWRT Kamikaze
Like the EX2700, the bootloader expects a secondary image signature,
see https://forum.openwrt.org/viewtopic.php?pid=312577#p312577
This device seems to be same hardware as a WN3000RPv3
Flash instructions:
- Use the Netgear WebUI to upgrade to OpenWRT using the factory image
(see note below),
- Use the sysupgrade image for upgrading versions from OpenWRT,
- TFTP recovery procedure can be used to flash the factory image
(preferred method).
Note:
- The WebUI may not reboot automatically, wait at least 5 minutes before
powercycling the device
Flashing using TFTP:
- Set you IP address to 192.168.1.10/24 (no gateway)
- Connect your machine to the Ethernet port
- Power off the device and wait for 10 seconds,
- Hold the reset button and power on the device (do not release reset),
- Hold the reset button until the green light is flashing (Approx. 15s)
- launch tftp, set mode to binary and connect to 192.168.1.1
- put the factory firmware image
- All leds will switch off (like a power off), this is normal
- Wait for the device to reboot in the new OpenWRT image (max 5 mins)
- The first boot will take longer than usual.
- After boot, the Device IP on the ethernet port is 192.168.1.1
Signed-off-by: Rodolphe de Saint Léger <rdesaintleger@gmail.com>
[drop unneeded includes in dts, wrap commit message]
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
The DWR-961 A1 Wireless Router is based on the MT7620A SoC.
It's a merge of two Amit boards: DWR-960 with ethernet part
of Lava LR-25G001.
ROMID it's taken from Telenor branded version and it works with tested
device. Images from D-Link site for this router are from DWR-953 and it
have ROMID DLK6E2424001. I don't know if it's mistake on web-site
or if it's will require different image.
Specification:
- MediaTek MT7620A (580 Mhz)
- 128 MB of RAM
- 16 MB of FLASH
- 1x 802.11bgn radio
- 1x 802.11ac radio (MT7612 mpcie card)
- 5x 10/100/1000 Mbps Ethernet: 4xLAN and 1xWAN (QCA8337)
- 2x internal, non-detachable antennas (Wifi 2.4G)
- 3x external, detachable antennas (2x LTE, 1x Wifi 5G)
- 1x LTE modem cat 6
- UART (J5) header on PCB (57600 8n1)
- 13x LED, 2x button
- JBOOT bootloader
Installation:
Apply factory image via http web-gui or JBOOT recovery page
How to revert to OEM firmware:
- push the reset button and turn on the power. Wait until LED start
blinking (~10sec.)
- upload original factory image via JBOOT http (IP: 192.168.123.254)
Signed-off-by: Pawel Dembicki <paweldembicki@gmail.com>
The I2C controller used in QorIQ PPC devices requires the mpc-i2c
driver, which is enabled by the I2C_MPC kernel config symbol. Enable
this and its dependencies in the target kernel config, as is done for
the mpc85xx target.
This fixes missing hwmon, rtc and tpm devices on the M300.
Signed-off-by: Stijn Tintel <stijn@linux-ipv6.be>
378b638c70c0 mt76: mt7915: fix unused variable with testmode disabled
4f4309542862 mt76: mt7915: only use u32_get_bits with constant value
de06d828a0bf mt76: mt7921: fix injected MPDU transmission to not use HW A-MSDU
c007ba3ec7a9 mt76: mt7915: simplify conditional
64c74dc93f68 mt76: fix dfs state issue with 160 MHz channels
d3471b0d92c1 mt76: mt7615: honor ret from mt7615_mcu_restart in mt7663u_mcu_init
f4c87b32e0e9 mt76: mt7663u: introduce mt7663u_mcu_power_on routine
82de5987af54 mt76: mt7921: fix up the monitor mode
c501df4086e1 mt76: mt7921: use mt76_hw instead of open coding it
594ee03d5a11 mt76: mt7915: fix DFS no radar detection event
d8d2b383a241 mt76: split single ldpc cap bit into bits
0f336fba20fe mt76: mt7921: make mt7921_init_tx_queues static
00a066ce9914 mt76: mt7921: fix xmit-queue dump for usb and sdio
d6d2479568b2 mt76: mt7921: fix mt7921_queues_acq implementation
d17b74420199 mt76: fix monitor mode crash with sdio driver
c374559eae6f mt76: mt7915: allow beaconing on all chains
b219af63b9ce mt76: connac: add 6 GHz support for wtbl and starec configuration
630384cb3246 mt76: mt7915: add 6 GHz support
28ff1bddc7e8 mt76: mt7915: fix eeprom fields of txpower init values
d4b226cc15e7 mt76: mt7915: add txpower init for 6GHz
31e820d4ce4b mt76: mt7921: get rid of mt7921_wait_for_mcu_init declaration
9fee1faf6028 mt76: mt7915: check for devm_pinctrl_get() failure
31a970940b97 mt76: connac: make read-only array ba_range static const
e49af7036bbc mt76: use le32/16_get_bits() whenever possible
0664d39039c2 mt76: fix invalid rssi report
f16fc9d96105 mt76: mt7915: set band1 TGID field in tx descriptor
67ce2708dcef mt76: mt7915: fix beamforming mib stats
6e899abec818 mt76: mt7915: fix phy cap in mt7915_set_stream_he_txbf_caps()
c6780c85cff2 mt76: mt7915: fix typos in comments
aa6eadc09a83 mt76: usb: add req_type to ___mt76u_rr signature
74a519ab8353 mt76: usb: add req_type to ___mt76u_wr signature
2651d2c66cbd mt76: usb: introduce __mt76u_init utility routine
c03e095eee27 mt76: mt7921: disable runtime pm for usb
41085cdcd7e3 mt76: mt7921: update mt7921_skb_add_usb_sdio_hdr to support usb
e700aba6bae3 mt76: mt7921: move mt7921_usb_sdio_tx_prepare_skb in common mac code
056b7f4ebcc6 mt76: mt7921: move mt7921_usb_sdio_tx_complete_skb in common mac code.
0abf682a3def mt76: mt7921: move mt7921_usb_sdio_tx_status_data in mac common code.
b0c60d5252de mt76: mt7921: add mt7921u driver
053668acdaf8 mt76: mt7921: move mt7921_init_hw in a dedicated work
Signed-off-by: Felix Fietkau <nbd@nbd.name>
Seeing failure to build because of missing symbols related to provisioning
CONFIG_KEXEC and signed images. Without this, if you set
CONFIG_KERNEL_KEXEC=y and try to build, target/linux will hang at:
scripts/kconfig/conf --syncconfig Kconfig
...
kexec system call (KEXEC) [Y/n/?] y
kexec file based system call (KEXEC_FILE) [Y/n/?] y
Verify kernel signature during kexec_file_load() syscall (KEXEC_SIG) [N/y/?] (NEW)
Signed-off-by: Philip Prindeville <philipp@redfish-solutions.com>
Backport patches
381a730182f1 ("net: dsa: Move VLAN filtering syncing out of dsa_switch_bridge_leave")
108dc8741c20 ("net: dsa: Avoid cross-chip syncing of VLAN filtering")
from upstream (currently in net-next) to fix null-pointer dereference.
Signed-off-by: Marek Behún <kabel@kernel.org>
LOCK_STATE_HELD define was omitted during backport of
lockdep_assert_not_held() which leads to build failures of kernels with
CONFIG_LOCKDEP=y:
backports-5.15.8-1/backport-include/linux/lockdep.h:16:47: error: 'LOCK_STATE_HELD' undeclared (first use in this function)
Fix it by adding missing LOCK_STATE_HELD define.
References: PR#9373
Reported-by: Oskari Rauta <oskari.rauta@gmail.com>
Signed-off-by: Petr Štetiar <ynezz@true.cz>
FCC ID: 2AG6R-AN700APIAC
Araknis AN-700-AP-I-AC is an indoor wireless access point with
1 Gb ethernet port, dual-band wireless,
internal antenna plates, and 802.3at PoE+
this board is a Senao device:
the hardware is equivalent to EnGenius EAP1750
the software is modified Senao SDK which is based on openwrt and uboot
including image checksum verification at boot time,
and a failsafe image that boots if checksum fails
**Specification:**
- QCA9558 SOC MIPS 74kc, 2.4 GHz WMAC, 3x3
- QCA9880 WLAN PCI card, 5 GHz, 3x3, 26dBm
- AR8035-A PHY RGMII GbE with PoE+ IN
- 40 MHz clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM NT5TU32M16
- UART console J10, populated, RX shorted to ground
- 4 antennas 5 dBi, internal omni-directional plates
- 4 LEDs power, 2G, 5G, wps
- 1 button reset
NOTE: all 4 gpio controlled LEDS are viewed through the same lightguide
therefore, the power LED is off for default state
**MAC addresses:**
MAC address labeled as ETH
Only one Vendor MAC address in flash at art 0x0
eth0 ETH *:xb art 0x0
phy1 2.4G *:xc ---
phy0 5GHz *:xd ---
**Serial Access:**
the RX line on the board for UART is shorted to ground by resistor R176
therefore it must be removed to use the console
but it is not necessary to remove to view boot log
optionally, R175 can be replaced with a solder bridge short
the resistors R175 and R176 are next to the UART RX pin at J10
**Installation:**
Method 1: Firmware upgrade page:
(if you cannot access the APs webpage)
factory reset with the reset button
connect ethernet to a computer
OEM webpage at 192.168.20.253
username and password 'araknis'
make a new password, login again...
Navigate to 'File Management' page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm
wait about 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fd70000`
wait a minute
connect to ethernet and navigate to
192.168.20.253
Select the factory.bin image and upload
wait about 3 minutes
**Return to OEM:**
Method 1: Serial to load Failsafe webpage (above)
Method 2: delete a checksum from uboot-env
this will make uboot load the failsafe image at next boot
because it will fail the checksum verification of the image
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait a minute
connect to ethernet and navigate to
192.168.20.253
select OEM firmware image and click upgrade
Method 3: backup mtd partitions before upgrade
**TFTP recovery:**
Requires serial console, reset button does nothing
rename initramfs-kernel.bin to '0101A8C0.img'
make available on TFTP server at 192.168.1.101
power board, interrupt boot with serial console
execute `tftpboot` and `bootm 0x81000000`
NOTE: TFTP may not be reliable due to bugged bootloader
set MTU to 600 and try many times
**Format of OEM firmware image:**
The OEM software is built using SDKs from Senao
which is based on a heavily modified version
of Openwrt Kamikaze or Altitude Adjustment.
One of the many modifications is sysupgrade being performed by a custom script.
Images are verified through successful unpackaging, correct filenames
and size requirements for both kernel and rootfs files, and that they
start with the correct magic numbers (first 2 bytes) for the respective headers.
Newer Senao software requires more checks but their script
includes a way to skip them.
The OEM upgrade script is at
/etc/fwupgrade.sh
OKLI kernel loader is required because the OEM software
expects the kernel to be less than 1536k
and the OEM upgrade procedure would otherwise
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035 switch between
the SOC and the ethernet port.
For QCA955x series, the PLL registers for eth0 and eth1
can be see in the DTSI as 0x28 and 0x48 respectively.
Therefore the PLL registers can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x18050028 1` and `md 0x18050048 1`.
The clock delay required for RGMII can be applied at the PHY side,
using the at803x driver `phy-mode` setting through the DTS.
Therefore, the Ethernet Configuration registers for GMAC0
do not need the bits for RGMII delay on the MAC side.
This is possible due to fixes in at803x driver
since Linux 5.1 and 5.3
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: 2AG6R-AN500APIAC
Araknis AN-500-AP-I-AC is an indoor wireless access point with
1 Gb ethernet port, dual-band wireless,
internal antenna plates, and 802.3at PoE+
this board is a Senao device:
the hardware is equivalent to EnGenius EAP1200
the software is modified Senao SDK which is based on openwrt and uboot
including image checksum verification at boot time,
and a failsafe image that boots if checksum fails
**Specification:**
- QCA9557 SOC MIPS 74kc, 2.4 GHz WMAC, 2x2
- QCA9882 WLAN PCI card 168c:003c, 5 GHz, 2x2, 26dBm
- AR8035-A PHY RGMII GbE with PoE+ IN
- 40 MHz clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM NT5TU32M16
- UART console J10, populated, RX shorted to ground
- 4 antennas 5 dBi, internal omni-directional plates
- 4 LEDs power, 2G, 5G, wps
- 1 button reset
NOTE: all 4 gpio controlled LEDS are viewed through the same lightguide
therefore, the power LED is off for default state
**MAC addresses:**
MAC address labeled as ETH
Only one Vendor MAC address in flash at art 0x0
eth0 ETH *:e1 art 0x0
phy1 2.4G *:e2 ---
phy0 5GHz *:e3 ---
**Serial Access:**
the RX line on the board for UART is shorted to ground by resistor R176
therefore it must be removed to use the console
but it is not necessary to remove to view boot log
optionally, R175 can be replaced with a solder bridge short
the resistors R175 and R176 are next to the UART RX pin at J10
**Installation:**
Method 1: Firmware upgrade page:
(if you cannot access the APs webpage)
factory reset with the reset button
connect ethernet to a computer
OEM webpage at 192.168.20.253
username and password 'araknis'
make a new password, login again...
Navigate to 'File Management' page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm
wait about 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fd70000`
wait a minute
connect to ethernet and navigate to
192.168.20.253
Select the factory.bin image and upload
wait about 3 minutes
**Return to OEM:**
Method 1: Serial to load Failsafe webpage (above)
Method 2: delete a checksum from uboot-env
this will make uboot load the failsafe image at next boot
because it will fail the checksum verification of the image
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait a minute
connect to ethernet and navigate to
192.168.20.253
select OEM firmware image and click upgrade
Method 3: backup mtd partitions before upgrade
**TFTP recovery:**
Requires serial console, reset button does nothing
rename initramfs-kernel.bin to '0101A8C0.img'
make available on TFTP server at 192.168.1.101
power board, interrupt boot with serial console
execute `tftpboot` and `bootm 0x81000000`
NOTE: TFTP may not be reliable due to bugged bootloader
set MTU to 600 and try many times
**Format of OEM firmware image:**
The OEM software is built using SDKs from Senao
which is based on a heavily modified version
of Openwrt Kamikaze or Altitude Adjustment.
One of the many modifications is sysupgrade being performed by a custom script.
Images are verified through successful unpackaging, correct filenames
and size requirements for both kernel and rootfs files, and that they
start with the correct magic numbers (first 2 bytes) for the respective headers.
Newer Senao software requires more checks but their script
includes a way to skip them.
The OEM upgrade script is at
/etc/fwupgrade.sh
OKLI kernel loader is required because the OEM software
expects the kernel to be less than 1536k
and the OEM upgrade procedure would otherwise
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035 switch between
the SOC and the ethernet port.
For QCA955x series, the PLL registers for eth0 and eth1
can be see in the DTSI as 0x28 and 0x48 respectively.
Therefore the PLL registers can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x18050028 1` and `md 0x18050048 1`.
The clock delay required for RGMII can be applied at the PHY side,
using the at803x driver `phy-mode` setting through the DTS.
Therefore, the Ethernet Configuration registers for GMAC0
do not need the bits for RGMII delay on the MAC side.
This is possible due to fixes in at803x driver
since Linux 5.1 and 5.3
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: U2M-AN300APIN
Araknis AN-300-AP-I-N is an indoor wireless access point with
1 Gb ethernet port, dual-band wireless,
internal antenna plates, and 802.3at PoE+
this board is a Senao device:
the hardware is equivalent to EnGenius EWS310AP
the software is modified Senao SDK which is based on openwrt and uboot
including image checksum verification at boot time,
and a failsafe image that boots if checksum fails
**Specification:**
- AR9344 SOC MIPS 74kc, 2.4 GHz WMAC, 2x2
- AR9382 WLAN PCI on-board 168c:0030, 5 GHz, 2x2
- AR8035-A PHY RGMII GbE with PoE+ IN
- 40 MHz clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM 1839ZFG V59C1512164QFJ25
- UART console J10, populated, RX shorted to ground
- 4 antennas 5 dBi, internal omni-directional plates
- 4 LEDs power, 2G, 5G, wps
- 1 button reset
NOTE: all 4 gpio controlled LEDS are viewed through the same lightguide
therefore, the power LED is off for default state
**MAC addresses:**
MAC address labeled as ETH
Only one Vendor MAC address in flash at art 0x0
eth0 ETH *:7d art 0x0
phy1 2.4G *:7e ---
phy0 5GHz *:7f ---
**Serial Access:**
the RX line on the board for UART is shorted to ground by resistor R176
therefore it must be removed to use the console
but it is not necessary to remove to view boot log
optionally, R175 can be replaced with a solder bridge short
the resistors R175 and R176 are next to the UART RX pin at J10
**Installation:**
Method 1: Firmware upgrade page:
(if you cannot access the APs webpage)
factory reset with the reset button
connect ethernet to a computer
OEM webpage at 192.168.20.253
username and password 'araknis'
make a new password, login again...
Navigate to 'File Management' page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm
wait about 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fd70000`
wait a minute
connect to ethernet and navigate to
192.168.20.253
Select the factory.bin image and upload
wait about 3 minutes
**Return to OEM:**
Method 1: Serial to load Failsafe webpage (above)
Method 2: delete a checksum from uboot-env
this will make uboot load the failsafe image at next boot
because it will fail the checksum verification of the image
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait a minute
connect to ethernet and navigate to
192.168.20.253
select OEM firmware image and click upgrade
Method 3: backup mtd partitions before upgrade
**TFTP recovery:**
Requires serial console, reset button does nothing
rename initramfs-kernel.bin to '0101A8C0.img'
make available on TFTP server at 192.168.1.101
power board, interrupt boot with serial console
execute `tftpboot` and `bootm 0x81000000`
NOTE: TFTP may not be reliable due to bugged bootloader
set MTU to 600 and try many times
**Format of OEM firmware image:**
The OEM software is built using SDKs from Senao
which is based on a heavily modified version
of Openwrt Kamikaze or Altitude Adjustment.
One of the many modifications is sysupgrade being performed by a custom script.
Images are verified through successful unpackaging, correct filenames
and size requirements for both kernel and rootfs files, and that they
start with the correct magic numbers (first 2 bytes) for the respective headers.
Newer Senao software requires more checks but their script
includes a way to skip them.
The OEM upgrade script is at
/etc/fwupgrade.sh
OKLI kernel loader is required because the OEM software
expects the kernel to be less than 1536k
and the OEM upgrade procedure would otherwise
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035 switch between
the SOC and the ethernet port.
For QCA955x series, the PLL registers for eth0 and eth1
can be see in the DTSI as 0x28 and 0x48 respectively.
Therefore the PLL registers can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x18050028 1` and `md 0x18050048 1`.
The clock delay required for RGMII can be applied at the PHY side,
using the at803x driver `phy-mode` setting through the DTS.
Therefore, the Ethernet Configuration registers for GMAC0
do not need the bits for RGMII delay on the MAC side.
This is possible due to fixes in at803x driver
since Linux 5.1 and 5.3
Signed-off-by: Michael Pratt <mcpratt@pm.me>
Some boards with firmware made with Senao SDK based on Linux 3.3
have the following lines in the OEM upgrade script at
/etc/fwupgrade.sh
local append=""
local CONF_TAR="/tmp/sysupgrade.tgz"
[ -f "$CONF_TAR" ] && append="-j $CONF_TAR"
and
\# check FWINFO filename
[ -z $(ls FWINFO* | grep -i ${modelname}) ] && errcode="1"
This addition also prevents needing to factory reset after flashing
for some boards that also have these lines in the script
\# Support downgrade but do default (Smart v2.x.x.x -> senaowrt v1.x.x.x)
[ $(ls FWINFO* | grep -i ${modelname} | cut -d "-" -f4 | cut -c 2) -lt 2 ] && append=""
Signed-off-by: Michael Pratt <mcpratt@pm.me>
Panasonic Switch-M8eG PN28080K is a 8 + 1 port gigabit switch, based on
RTL8380M.
Specification:
- SoC : Realtek RTL8380M
- RAM : DDR3 128 MiB (Winbond W631GG8KB-15)
- Flash : SPI-NOR 32 MiB (Macronix MX25L25635FMI-10G)
- Ethernet : 10/100/1000 Mbps x8 + 1
- port 1-8 : TP, RTL8218B (SoC)
- port 9 : SFP, RTL8380M (SoC)
- LEDs/Keys : 7x / 1x
- UART : RS-232 port on the front panel (connector: RJ-45)
- 3:TX, 4:GND, 5:GND, 6:RX (pin number: RJ-45)
- 9600n8
- Power : 100-240 VAC, 50/60 Hz, 0.5 A
- Plug : IEC 60320-C13
- Stock OS : VxWorks based
Flash instruction using initramfs image:
1. Prepare the TFTP server with the IP address 192.168.1.111
2. Rename the OpenWrt initramfs image to "0101A8C0.img" and place it to
the TFTP directory
3. Download the official upgrading firmware (ex: pn28080k_v30000.rom)
and place it to the TFTP directory
4. Boot M8eG and interrupt the U-Boot with Ctrl + C keys
5. Execute the following commands and boot with the OpenWrt initramfs
image
rtk network on
tftpboot 0x81000000
bootm
6. Backup mtdblock files to the computer by scp or anything and reboot
7. Interrupt the U-Boot and execute the following commands to re-create
filesystem in the flash
ffsmount c:/
ffsfmt c:/
this step takes a long time, about ~ 4 mins
8. Execute the following commands to put the official images to the
filesystem
updatert <official image>
example:
updatert pn28080k_v30000.rom
this step takes about ~ 40 secs
9. Set the environment variables of the U-Boot by the following commands
setenv loadaddr 0xb4e00000
setenv bootcmd bootm
saveenv
10: Download the OpenWrt initramfs image and boot with it
tftpboot 0x81000000 0101A8C0.img
bootm
11: On the initramfs image, download the sysupgrade image and perform
sysupgrade with it
sysupgrade <imagename>
12: Wait ~ 120 seconds to complete flashing
Note:
- "Switch-M8eG" is a model name, and "PN28080K" is a model number.
Switch-M8eG has an another (old) model number ("PN28080"), it's not a
Realtek based hardware.
- Switch-M8eG has a "POWER" LED (Green), but it's not connected to any
GPIO pin.
- The U-Boot checks the runtime images in the flash when booting and
fails to execute anything in "bootcmd" variable if the images are not
exsisting.
- A filesystem is formed in the flash (0x100000-0x1DFFFFF) on the stock
firmware and it includes the stock images, configuration files and
checksum files. It's unknown format, can't be managed on the OpenWrt.
To get the enough space for OpenWrt, move the filesystem to the head
of "fs_reserved" partition by execution of "ffsfmt" and "updatert".
- On the other devices in the same series of Switch-M8eG PN28080K, the
INT pin on the PCA9555 is not connected to anywhere.
Back to the stock firmware:
1. Delete "loadaddr" variable and set "bootcmd" to the original value
on U-Boot:
setenv loadaddr
setenv bootcmd 'bootm 0x81000000'
on OpenWrt:
fw_setenv loadaddr
fw_setenv bootcmd 'bootm 0x81000000'
2. Perform reset or reboot
on U-Boot:
reset
on OpenWrt:
reboot
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Reviewed-by: Sander Vanheule <sander@svanheule.net>
The system status LED on Panasonic Switch-M8eG PN28080K is connected to
a PCA9539PW. To use the LED as a status LED of OpenWrt while booting,
enable the pca953x driver and built-in to the kernel.
Also enable CONFIG_GPIO_PCA953X_IRQ to use interrupt via RTL83xx GPIO.
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Acked-by: Sander Vanheule <sander@svanheule.net>
The ZyXEL GS1900-24 v1 is a 24 port switch with two SFP ports, similar to
the other GS1900 switches.
Specifications
--------------
* Device: ZyXEL GS1900-24 v1
* SoC: Realtek RTL8382M 500 MHz MIPS 4KEc
* Flash: 16 MiB
* RAM: Winbond W9751G8KB-25 64 MiB DDR2 SDRAM
* Ethernet: 24x 10/100/1000 Mbps, 2x SFP 100/1000 Mbps
* LEDs:
* 1 PWR LED (green, not configurable)
* 1 SYS LED (green, configurable)
* 24 ethernet port link/activity LEDs (green, SoC controlled)
* 2 SFP status/activity LEDs (green, SoC controlled)
* Buttons:
* 1 "RESET" button on front panel (soft reset)
* 1 button ('SW1') behind right hex grate (hardwired power-off)
* Power: 120-240V AC C13
* UART: Internal populated 10-pin header ('J5') providing RS232;
connected to SoC UART through a SIPEX 3232EC for voltage
level shifting.
* 'J5' RS232 Pinout (dot as pin 1):
2) SoC RXD
3) GND
10) SoC TXD
Serial connection parameters: 115200 8N1.
Installation
------------
OEM upgrade method:
* Log in to OEM management web interface
* Navigate to Maintenance > Firmware > Management
* If "Active Image" has the first option selected, OpenWrt will need to be
flashed to the "Active" partition. If the second option is selected,
OpenWrt will need to be flashed to the "Backup" partition.
* Navigate to Maintenance > Firmware > Upload
* Upload the openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-initramfs-kernel.bin
file by your preferred method to the previously determined partition.
When prompted, select to boot from the newly flashed image, and reboot
the switch.
* Once OpenWrt has booted, scp the sysupgrade image to /tmp and flash it:
> sysupgrade /tmp/openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-squashfs-sysupgrade.bin
U-Boot TFTP method:
* Configure your client with a static 192.168.1.x IP (e.g. 192.168.1.10).
* Set up a TFTP server on your client and make it serve the initramfs
image.
* Connect serial, power up the switch, interrupt U-boot by hitting the
space bar, and enable the network:
> rtk network on
> Since the GS1900-24 v1 is a dual-partition device, you want to keep the
OEM firmware on the backup partition for the time being. OpenWrt can
only be installed in the first partition anyway (hardcoded in the
DTS). To ensure we are set to boot from the first partition, issue the
following commands:
> setsys bootpartition 0
> savesys
* Download the image onto the device and boot from it:
> tftpboot 0x81f00000 192.168.1.10:openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-initramfs-kernel.bin
> bootm
* Once OpenWrt has booted, scp the sysupgrade image to /tmp and flash it:
> sysupgrade /tmp/openwrt-realtek-rtl838x-zyxel_gs1900-24-v1-squashfs-sysupgrade.bin
Signed-off-by: Martin Kennedy <hurricos@gmail.com>
Add option to compile kmod-inet-diag, support for INET (TCP, DCCP, etc)
socket monitoring interface used by native Linux tools such as ss.
Signed-off-by: Tianling Shen <cnsztl@immortalwrt.org>
When porting mwan3 from iptables to nftables I tried the new translation
tool for ipset ipset-translate. I noticed that no IPv6 ipset can be
created with the tool. I have reported the problem to the upstream
project and the following patch fixes the problem.
Until this upsream is included in a new release, this patch should be
used in Openwrt.
https://lore.kernel.org/netfilter-devel/20220228190217.2256371-1-pablo@netfilter.org/T/#m09cc3cb738f2e42024c7aecf5b7240d9f6bbc19c
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Applies changes from 7774b86019 to new device committed later. Fix some
whitespace in the DTS. Use standard model name format in DTS.
Fixes: 6c743c3006 ("ramips: Add support for TP-Link TL-WPA8631P v3")
Signed-off-by: Joe Mullally <jwmullally@gmail.com>
Reported-by: Arınç ÜNAL <arinc.unal@arinc9.com>
Keep labels since OpenWrt userland tooling (get_dt_led) depends on them
to find the LED instances referenced by the led-* aliases.
The label for the amber power LED was removed in 4eefdc7adb.
Signed-off-by: Sven Schwermer <sven@svenschwermer.de>
MAC addresses on OEM firmware:
04:xx:xx:xx:xx:c8 factory 0x4 wlan2g
06:xx:xx:xx:xx:c8 [not on flash] wlan5g
Signed-off-by: Chukun Pan <amadeus@jmu.edu.cn>
The wireless mac address difference of this machine is similar
to that of D-Link DIR-853-R1, so use the same practice.
Signed-off-by: Chukun Pan <amadeus@jmu.edu.cn>
Dual-Q H721 is a router platform board, it is the smaller model of
the U7621-06.
The device has the following specifications:
MT7621AT (880 MHz)
256 of RAM (DDR3)
16 MB of FLASH (MX25l12805d SPI)
5x 1 Gbps Ethernet (MT7621 built-in switch)
1x M.2 (NGFF) 3.7V 3A max for 5G M.2 Modem work at USB3.0 mode
1x Minipcie 3.7V 3A max for LTE Modem work at USB2.0 Mode
2x Minipcie for WIFI card
4x Lan+1x Wan 10/100M/1000M RJ45 port
14x LEDs (1x GPIO-controlled)
1x reset button
1x UART header (4-pins)
1x mico SD-card reader
1x DC jack for main power (5~27 V)
The following has been tested and is working:
Ethernet switch
miniPCIe slots (tested with Wi-Fi cards and LTE modem cards)
miniSIM slot (works with normal size simcard)
sysupgrade
reset button
micro SD-card reader
Installation:
This board has no locked down bootloader. The seller can be asked to
install openwrt, so upgrades are standard sysupgrade method.
Recovery:
This board contains a Chinese, closed-source bootloader called Breed
(Boot and Recovery Environment for Embedded Devices). Breed supports web
recovery and to enter it, you keep the reset button pressed for around
5 seconds during boot. Your machine will be assigned an IP through DHCP
and the router will use IP address 192.168.1.1. The recovery website is
in Chinese, but is easy to use. Click on the second item in the list to
access the recovery page, then the second item on the next page is where
you select the firmware. In order to start the recovery, you click the
button at the bottom.
Signed-off-by: Dawsen Gao <dawsen_gao@163.com>
[change author name (used SoB one), add ethernet pinctrl,
apply sorting to device recipe]
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
OpenWrt uses a lot of (b)ash scripts for initial setup. This isn't the
best solution as they almost never consider syncing files / data. Still
this is what we have and we need to try living with it.
Without proper syncing OpenWrt can easily get into an inconsistent state
on power cut. It's because:
1. Actual (flash) inode and data writes are not synchronized
2. Data writeback can take up to 30 seconds (dirty_expire_centisecs)
3. ubifs adds extra 5 seconds (dirty_writeback_centisecs) "delay"
Some possible cases (examples) for new files:
1. Power cut during 5 seconds after write() can result in all data loss
2. Power cut happening between 5 and 35 seconds after write() can result
in empty file (inode flushed after 5 seconds, data flush queued)
Above affects e.g. uci-defaults. After executing some migration script
it may get deleted (whited out) without generated data getting actually
written. Power cut will result in missing data and deleted file.
There are three ways of dealing with that:
1. Rewriting all user-space init to proper C with syncs
2. Trying bash hacks (like creating tmp files & moving them)
3. Adding sync and hoping for no power cut during critical section
This change introduces the last solution that is the simplest. It
reduces time during which things may go wrong from ~35 seconds to
probably less than a second. Of course it applies only to IO operations
performed before /etc/init.d/boot . It's probably the stage when the
most new files get created.
All later changes are usually done using smarter C apps (e.g. busybox or
uci) that creates tmp files and uses rename() that is expected to be
atomic.
Signed-off-by: Rafał Miłecki <rafal@milecki.pl>
Acked-by: Hauke Mehrtens <hauke@hauke-m.de>
Acked-by: Sergey Ryazanov <ryazanov.s.a@gmail.com>
Modems used in ZTE mobile broadband routers require to query the data
session status using the same CID as one used to establish the session,
otherwise they will report the session as "disconnected" despite
reporting correct PDH in previous step. Without this change, IPv6
connection on these modems doesn't establish properly. In IPv4 this bug
is present as well, but for some reason querying of IPv4 status works
using temporary CID, this however seems noncompliant with QMI
specifications, so fix it as well.
Signed-off-by: Lech Perczak <lech.perczak@gmail.com>
The ChipIdea USB kernel driver gained support for disabling glue drivers
in 5.8, see upstream commmit: 95caa2ae70fd ("usb: chipidea: allow
disabling glue drivers if EMBEDDED").
This enables 'CONFIG_USB_CHIPIDEA_IMX' in the 'imx' target kernel config
which brings back USB support.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
This driver is needed to boot from CompactFlash on the Siemens Futro S400.
The device has an AMD NX1500 CPU, which seems to be unsupported by the
geode subtarget, so it must use legacy.
Signed-off-by: Matthias Schiffer <mschiffer@universe-factory.net>
Add patch found in Teltonika RUT9_R_00.07.01.4 GPL SDK download[1]
adding USB IDs of the MeigLink SLM750 to the relevant kernel drivers.
Newer versions of Teltonika's 2G/3G/4G RUT9XX WWAN router series come
with this kind of modem.
[1]: https://wiki.teltonika-networks.com/view/GPL
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
Previously libxt_socket.so was included in iptables-mod-tproxy. It was
missed out when trying to make kmod-ipt-socket and kmod-ipt-tproxy
separate packages
Fixes: 4f443c88 ("netfilter: separate packages for kmod-ipt-socket and kmod-ipt-tproxy")
Signed-off-by: Yousong Zhou <yszhou4tech@gmail.com>
Artifacts can only be uploaded from inside the GITHUB_WORKSPACE. While
the Linux CI jobs run inside that per default, a special case-sensitive
mount outside the GITHUB_WORKSPACE is used for macOS builds.
To make log artifacts work for both macOS and Linux, move logs/ folder
to GITHUB_WORKSPACE on failures.
Signed-off-by: Paul Spooren <mail@aparcar.org>
By switching EPHY_LED4_N_JTRST_N from EPHY_LED4_N to GPIO#39
we can control USB port power an all current revisions of MR3020v3.
It was not a thing on some first revisions, pin was unused.
But for now on all current MR3020v3 boards EPHY_LED4_N_JTRST_N pin
is connected to USB power key.
Also it was not used as EPHY indicator on any revision of the board.
Signed-off-by: Dmitry Chigiryov <dmitry.chigiryov@ya.ru>
[changed author address (used SoB one)]
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
In commit ee66fe4ea9 ("ramips: convert DEVICE_TITLE to new variables"),
DEVICE_VENDOR of some unbranded devices were set incorrectly:
* WR512-3GN is not a dev board from Ralink.
* "XDX-RN502J" is the whole model name and should be not split.
This patch sets their DEVICE_VENDOR to "Unbranded", and changes their DTS
model properties accordingly.
Ref: d0bf15f235 ("ramips: add support for A5-V11 board (resubmit)")
Ref: 9085b05d9e ("ramips: rt305x: support for wr512-3gn-like routers")
Ref: 0e486d2fd2 ("ramips: add support for unbranded XDX-RN502J board")
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
Zbtlink ZBT-WG1608 is a Wi-Fi router intendent to use with WWAN (4G/5G)
modems.
Specifications:
* SoC: MediaTek MT7621A
* RAM: 256/512 MiB
* Flash: 16/32 MiB (SPI NOR)
* Wi-Fi:
* MediaTek MT7603E : 2.4Ghz
* MediaTek MT7613BE : 5Ghz
* Ethernet: 10/100/1000 Mbps Ethernet x5 ports (4xLAN + WAN)
* M.2: 1x slot with USB&SIM
* EM7455/EM12-G/EM160R/RM500Q-AE
* USB: 1x 3.0 Type-A port
* External storage: 1x microSD (SDXC) slot
* UART: console (115200 baud)
* LED:
* 1 power indicator
* 1 WLAN 2.4G controlled (wlan 2G)
* 3 SoC controlled (wlan 5G, wwan, internet)
* 5 per Eth phy (4xLAN + WAN)
MAC Addresses:
* LAN : f8:5e:3c:xx:xx:e0 (Factory, 0xe000 (hex))
* WAN : f8:5e:3c:xx:xx:e1 (Factory, 0xe006 (hex))
* 2.4 GHz: f8:5e:3c:xx:xx:de (Factory, 0x0004 (hex))
* 5 GHz : f8:5e:3c:xx:xx:df (Factory, 0x8004 (hex))
Installation:
* Vendor's firmware is OpenWrt (LEDE) based, so the sysupgrade image can
be directly used to install OpenWrt. Firmware must be upgraded using the
'force' and 'do not save configuration' command line options (or
correspondig web interface checkboxes) since the vendor firmware is from
the pre-DSA era.
Recovery Mode:
* Press reset button, power up the device, wait for about 10sec.
* Upload sysupgrade image through the firmware recovery mode web page at
192.168.1.1.
Signed-off-by: Kim Namu <namu@theseed.io>
Asus RT-AC1200 is a 2.4/5GHz dual band AC router,
based on MediaTek MT7628AN.
Specification:
* SoC: MT7628AN
* RAM: DDR2 64 MiB
* Flash: 16 MiB NOR (W25Q128BV)
* Wi-Fi:
* 2.4GHz: SoC Built-in
* 5GHz: MT7612EN
* Ethernet: 5x 100Mbps
* Switch: SoC built-in
* USB: 1x 2.0
Flash Layout:
0x0000000-0x0030000 : "bootloader"
0x0030000-0x0040000 : "nvram"
0x0040000-0x0050000 : "factory"
0x0050000-0x1000000 : "firmware"
MAC address:
LAN: factory 0x28
WAN: factory 0x22
2.4G: factory 0x4
5G: factory 0x8004
Installation via **recovery** mode:
1. Download the Asus recovery firmware (windows) tool from
http://dlcdnet.asus.com/pub/ASUS/LiveUpdate/Release/Wireless/Rescue.zip
2. Set your ethernet IP manually 192.168.1.5 / 255.255.255.0 with NO
gateway.
3. Plug in your ethernet to LAN port 1 on the router.
4. Load up the recovery software with the firmware file, but don't press
"Upload" yet.
5. Plug in the router to power WHILE HOLDING the reset button in. While
CONTINUING to hold the button, select "Upload" Continue to hold the
reset button in until it finishes and verifies!
6. If that doesn't work try pressing "Upload" first just before you do
step 5. At some point while holding reset the rescue tool will finally
detect and upload the firmware. That's when you can let go of the
reset button.
7. The router will reboot and not much will happen. Wait a minute or 2.
8. Power off and on the router again. Voila. Set everything your Ethernet
IP back to DHCP (automatically) and you're good to go.
Revert to stock firmware:
1. Install stock image via recovery mode.
Tested-by: Ivan Pavlov <AuthorReflex@gmail.com>
Signed-off-by: Ray Wang <raywang777@foxmail.com>
Zip always try to generate new encryption header depending on execution
time and process id, which is far from being reproducible. This commit
changes the zip srand() seed to a predictable value to generate
reproducible random bytes for the encryption header. This will compromise
the goal of secure archive encryption, but it would not be a big problem
for our purpose.
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
Remove "--mtime" option introduced in commit 18c9faa032 ("tools: zip:
add option for reproducible archives") and instead fetch SOURCE_DATE_EPOCH
environment variable directly in the code.
Ref: https://sourceforge.net/p/infozip/patches/25/
Signed-off-by: Sungbo Eo <mans0n@gorani.run>