update_kernel.sh refreshed all patches, no human interaction was needed
Build system: x86_64
Run-tested: Netgear R7800 (ipq806x)
Signed-off-by: John Audia <graysky@archlinux.us>
At this point in v5.4 kernel we cannot use dwc2_readl() and
dwc2_writel() since they rely on the value hsotg->needs_byte_swap
which cannot be obtained before the controller wakes up.
We should use readl() and writel() to wake up the controller before
calling dwc2_check_core_endianness().
Fixes: 6be0da90a1 ("ramips: refresh patches")
Signed-off-by: Alexey Dobrovolsky <dobrovolskiy.alexey@gmail.com>
[fixed Fixes: tag]
Signed-off-by: Petr Štetiar <ynezz@true.cz>
In FS#2738 we can see that patch first introduced in
e8ebcff ("ramips: add a explicit reset to dwc2")
breaks USB functionality since 18.06. Thus, this patch should be removed.
Removed:
- 0032-USB-dwc2-add-device_reset.patch
Fixes: FS#2738
Fixes: FS#2964
Signed-off-by: Alexey Dobrovolsky <dobrovolskiy.alexey@gmail.com>
Upstream pinctrl driver in drivers/staging uses
groups/function/ralink,num-gpios instead of
ralink,group/ralink,function/ralink,nr-gpio
Replace these properties in dts as well as the pinctrl driver in
patches-4.14.
This commit is created using:
sed -i 's/ralink,group/groups/g'
sed -i 's/ralink,function/function/g'
sed -i 's/ralink,nr-gpio/ralink,num-gpios/g'
Signed-off-by: Chuanhong Guo <gch981213@gmail.com>
This hack is needed for old ethernet driver:
On mt7620, we have two exposed RGMII ports that connects to builtin
switch. However, swconfig has no way to interact with phy subsystem.
As a result, we have to register both PHYs to ethernet mac instead
and this patch prevents main ethernet interface from going down due
to phy link changes.
Also rename the patch for its actual purpose.
Signed-off-by: Chuanhong Guo <gch981213@gmail.com>
Instead of resetting flash to 3B address on remove hook, this
implementation only enters 4B mode when needed, which prevents more
unexpected reboot stuck. This implementation makes it only break when
a kernel panic happens during flash operation on 16M+ areas.
Also silent broken-flash-reset warning. We are not dealing with vendors
and it's unpleasant for users to see that unnecessary and long WARN_ON
print.
Signed-off-by: Chuanhong Guo <gch981213@gmail.com>
mt7621 SoC has its own 'ralink_soc_info' structure with some
information about the soc itself. Pcie controller and pcie phy
drivers for this soc which are still in staging git tree make uses
of 'soc_device_attribute' looking for revision 'E2' in order to
know if reset lines are or not inverted. This way of doing things
seems to be necessary in order to make things clean and properly.
Hence, introduce this 'soc_device' to be able to properly use those
attributes in drivers. Also set 'data' pointer points to the struct
'ralink_soc_info' to be able to export also current soc information
using this mechanism.
Signed-off-by: DENG Qingfang <dengqf6@mail2.sysu.edu.cn>