Add a new dtsi which contains the common parts of Fortinet
FortiGate/FortiWiFi 3xE series devices.
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
Rename the common dtsi of Fortinet FortiGate 30E/50E for the preparation
of adding support for the other FortiGate/FortiWiFi 3xE/5xE devices.
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
On IIJ SA-W2, some multiple LEDs have no "function" property and only
"color" property is available for the newer binding of LED on Linux
Kernel.
9d93b6d091 ("mvebu: drop redundant label with new LED color/function
format") removes "label" property from LEDs, then, multiple "<color>:"
(ex.: "green:"/"red:") will be appeared and renamed to "<color>:_<num>"
(ex.: "green:_1", "green:_2", ...) by kernel.
log:
[ 1.911118] leds-gpio leds: Led green: renamed to green:_1 due to name collision
[ 1.918600] leds-gpio leds: Led red: renamed to red:_1 due to name collision
[ 1.925727] leds-gpio leds: Led green: renamed to green:_2 due to name collision
[ 1.933202] leds-gpio leds: Led red: renamed to red:_2 due to name collision
[ 1.940321] leds-gpio leds: Led green: renamed to green:_3 due to name collision
[ 1.947797] leds-gpio leds: Led red: renamed to red:_3 due to name collision
[ 1.954939] leds-gpio leds: Led green: renamed to green:_4 due to name collision
[ 1.962456] leds-gpio leds: Led green: renamed to green:_5 due to name collision
/sys/class/leds:
root@OpenWrt:/# ls /sys/class/leds/
green: green:_3 green:status red:_2
green:_1 green:_4 red: red:_3
green:_2 green:_5 red:_1 red:status
Fix this issue by adding missing "function" (and "function-enumerator")
property to those LEDs on IIJ SA-W2.
Fixes: 9d93b6d091 ("mvebu: drop redundant label with new LED color/function format")
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
On Fortinet FortiGate 30E/50E, some multiple LEDs have no "function"
property and only "color" property is available for the new binding of
LED on Linux Kernel.
9d93b6d091 ("mvebu: drop redundant label with new LED color/function
format") removes "label" property from LEDs, then, multiple "<color>:"
(ex.: "green:"/"red:"/"amber:") will be appeared as LED names and
renamed to "<color>:_<num>" (ex.: "green:_1", "green:_2", ...) by
kernel.
log:
[ 12.425170] leds-gpio gpio-leds: Led green: renamed to green:_1 due to name collision
[ 12.520390] leds-gpio gpio-leds: Led amber: renamed to amber:_1 due to name collision
[ 12.614931] leds-gpio gpio-leds: Led green: renamed to green:_2 due to name collision
[ 12.709895] leds-gpio gpio-leds: Led green: renamed to green:_3 due to name collision
[ 12.804439] leds-gpio gpio-leds: Led amber: renamed to amber:_2 due to name collision
[ 12.898969] leds-gpio gpio-leds: Led green: renamed to green:_4 due to name collision
[ 12.993504] leds-gpio gpio-leds: Led amber: renamed to amber:_3 due to name collision
[ 13.088033] leds-gpio gpio-leds: Led green: renamed to green:_5 due to name collision
[ 13.182570] leds-gpio gpio-leds: Led green: renamed to green:_6 due to name collision
[ 13.277103] leds-gpio gpio-leds: Led amber: renamed to amber:_4 due to name collision
[ 13.371636] leds-gpio gpio-leds: Led green: renamed to green:_7 due to name collision
/sys/class/leds:
root@OpenWrt:/# ls /sys/class/leds/
amber: amber:_4 green:_2 green:_6 red:alarm
amber:_1 amber:alarm green:_3 green:_7 red:status
amber:_2 green: green:_4 green:status
amber:_3 green:_1 green:_5 red:
Fix this issue by adding missing "function" (and "function-enumerator")
property those to LEDs on Fortinet FortiGate devices.
Note: there is no appropriate function for "ha" LEDs in
dt-bindings/leds/common.h, so use the hardcoded string for them instead.
Fixes: 9d93b6d091 ("mvebu: drop redundant label with new LED color/function format")
Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
As of 6.6, all upstream DTSes are moved to their respective vendor subdir.
OpenWrt already followed this practice for ARM64, but not yet for 32 bit
ARM (Armada 37x/38x).
Signed-off-by: Stijn Segers <foss@volatilesystems.org>