mirror of
https://github.com/openwrt/openwrt.git
synced 2024-12-30 18:47:06 +00:00
2fc170cc21
1 Commits
Author | SHA1 | Message | Date | |
---|---|---|---|---|
Michael Pratt
|
146aaeafb7 |
ath79: add support for Senao WatchGuard AP300
FCC ID: Q6G-AP300 WatchGuard AP300 is an indoor wireless access point with 1 Gb ethernet port, dual-band wireless, internal antenna plates, and 802.3at PoE+ this board is a Senao device: the hardware is equivalent to EnGenius EAP1750 the software is modified Senao SDK which is based on openwrt and uboot including image checksum verification at boot time, and a failsafe image that boots if checksum fails **Specification:** - QCA9558 SOC MIPS 74kc, 2.4 GHz WMAC, 3x3 - QCA9880 WLAN PCI card 168c:003c, 5 GHz, 3x3, 26dBm - AR8035-A PHY RGMII GbE with PoE+ IN - 40 MHz clock - 32 MB FLASH S25FL512S - 2x 64 MB RAM NT5TU32M16 - UART console J10, populated - GPIO watchdog GPIO 16, 20 sec toggle - 6 antennas 5 dBi, internal omni-directional plates - 5 LEDs power, eth0 link/data, 2G, 5G - 1 button reset **MAC addresses:** MAC address labeled as ETH Only one Vendor MAC address in flash at art 0x0 eth0 ETH *:3c art 0x0 phy1 ---- *:3d --- phy0 ---- *:3e --- **Serial console access:** For this board, its not certain whether UART is possible it is likely that software is blocking console access the RX line on the board for UART is shorted to ground by resistor R176 the resistors R175 and R176 are next to the UART RX pin at J10 however console output is garbage even after this fix **Installation:** Method 1: OEM webpage use OEM webpage for firmware upgrade to upload factory.bin Method 2: root shell access downgrade XTM firewall to v2.0.0.1 downgrade AP300 firmware: v1.0.1 remove / unpair AP from controller perform factory reset with reset button connect ethernet to a computer login to OEM webpage with default address / pass: wgwap enable SSHD in OEM webpage settings access root shell with SSH as user 'root' modify uboot environment to automatically try TFTP at boot time (see command below) rename initramfs-kernel.bin to test.bin load test.bin over TFTP (see TFTP recovery) (optionally backup all mtdblocks to have flash backup) perform a sysupgrade with sysupgrade.bin NOTE: DHCP is not enabled by default after flashing **TFTP recovery:** server ip: 192.168.1.101 reset button seems to do nothing at boot time... only possible with modified uboot environment, running this command in the root shell: fw_setenv bootcmd 'if ping 192.168.1.101; then tftp 0x82000000 test.bin && bootm 0x82000000; else bootm 0x9f0a0000; fi' and verify that it is correct with fw_printenv then, before boot, the device will attempt TFTP from 192.168.1.101 looking for file 'test.bin' to return uboot environment to normal: fw_setenv bootcmd 'bootm 0x9f0a0000' **Return to OEM:** user should make backup of MTD partitions and write the backups back to mtd devices in order to revert to OEM (see installation method 2) It may be possible to use sysupgrade with an OEM image as well... (not tested) **OEM upgrade info:** The OEM upgrade script is at /etc/fwupgrade.sh OKLI kernel loader is required because the OEM software expects the kernel to be no greater than 1536k and the factory.bin upgrade procedure would otherwise overwrite part of the kernel when writing rootfs. **Note on eth0 PLL-data:** The default Ethernet Configuration register values will not work because of the external AR8035 switch between the SOC and the ethernet port. For QCA955x series, the PLL registers for eth0 and eth1 can be see in the DTSI as 0x28 and 0x48 respectively. Therefore the PLL registers can be read from uboot for each link speed after attempting tftpboot or another network action using that link speed with `md 0x18050028 1` and `md 0x18050048 1`. The clock delay required for RGMII can be applied at the PHY side, using the at803x driver `phy-mode`. Therefore the PLL registers for GMAC0 do not need the bits for delay on the MAC side. This is possible due to fixes in at803x driver since Linux 5.1 and 5.3 **Note on WatchGuard Magic string:** The OEM upgrade script is a modified version of the generic Senao sysupgrade script which is used on EnGenius devices. On WatchGuard boards produced by Senao, images are verified using a md5sum checksum of the upgrade image concatenated with a magic string. this checksum is then appended to the end of the final image. This variable does not apply to all the senao devices so set to null string as default Tested-by: Alessandro Kornowski <ak@wski.org> Tested-by: John Wagner <john@wagner.us.org> Signed-off-by: Michael Pratt <mcpratt@pm.me> |