On boards which don't have a distinct internet and dsl led, use the
shared LED to indicate the xdsl line state and any traffic that is
send/received via the netdev. This traffic doesn't necessarily need to
be internet traffic.
Rename the shared LED of existing configs to "dsl", to match the new
defaults. The configuration of the to be renamed LED is identical with
the new defaults.
Signed-off-by: Mathias Kresin <dev@kresin.me>
Allows to use a single LED for line init status indication and to show
any rx/tx activity on a synchronized dsl line.
Signed-off-by: Martin Schiller <ms@dev.tdt.de>
Signed-off-by: Mathias Kresin <dev@kresin.me>
As of now OTP is being correctly parsed and the driver requires to parse pre-caldata to follow corresponding routine.
Rename cal file into pre-calfile so the board initialized correctly with API 2 board data (board-2.bin).
Also remove the now unneeded for qca9984 board.bin symlink to 5GHz calfile.
Signed-off-by: Pavel Kubelun <be.dissent@gmail.com>
The Cisco ON100 device is a Kirkwood based router:
SoC: Marvell 88F6282 1600Mhz
SDRAM memory: 512MB DDR3 1333Mhz
Gigabit ethernet: 2x Marvell 88E1310 (over RGMII)
Flash memory: 512MB
2 bi-colour status LEDs (green/red)
1 Reset button
1 USB 2.0 port (on back)
1 SDIO slot (on back)
This commit adds a target profile of "Cisco Systems ON100" under the target
system "Marvell Kirkwood".
Flashing can be performed over tftp, once "dhcp" has been issued:
tftpboot ${loadaddr} lede-kirkwood-on100-squashfs-factory.bin
nand erase 0x0c0000 ${filesize}
nand write ${loadaddr} 0x0c0000 ${filesize}
Once flashed, set environment variables to boot:
setenv bootcmd nand read \${loadaddr} 0x0c0000 0x540000\; setenv bootargs
\; bootm
saveenv
Signed-off-by: Makoto Takeuchi <mak0@lxsys.co.uk>
Evaluation boards are left in component form to ease flashing
using vendor tooling and instructions. These boards also do
not include the EOF marker in the UBIFS as the bootloaders
are recent and easily upgradeable.
The end product boards use factory.bin images based on the
dts layout and include EOF markers as bootloader UBI support
is not determined.
Signed-off-by: Ben Whitten <ben.whitten@gmail.com>
Signed-off-by: Mathias Kresin <dev@kresin.me>
All TP-Link TL-WR710N versions share the same machine code.
This has been working since the beginning as we don't use double-quotes
to protect spaces inside command line values. Thus, kernel interprets
'board=TL-WR710N v2' as 'board=TL-WR710N' and separate parameter 'v2'.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
Keep TP-Link devices definitions in alphabetical order whenever it's
possible. Also group together similar devices or devices from the same
series.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
TP-Link TL-WR942N v1 is a 2.4 GHz single-band N450 router, based on
Qualcomm/Atheros QCA9561.
Specification:
- 775/650/258 MHz (CPU/DDR/AHB)
- 128 MB of RAM (DDR2)
- 16 MB of FLASH (SPI NOR)
- 3T3R 2.4 GHz
- 5x 10/100 Mbps Ethernet
- 2x USB 2.0
- 11x LED (most are controlled by 74HC595)
- 2x button
- UART header on PCB*
* Serial console is disabled in OEM non-beta firmwares and corresponding
GPIO pins 14 and 15 are assigned to control USB1 and USB2 LEDs by
production (non-beta) U-Boot and firmware.
Currently not working:
1. USB1 and USB2 LEDs if UART RX and TX pins are assigned to their GPIOs
by some U-Boot versions.
Flash instruction under vendor GUI:
1. Download "lede-ar71xx-generic-tl-wr942n-v1-squashfs-factory.bin".
2. Go to WEB interface and perform usual firmware upgrade.
FLash instruction under U-Boot recovery mode (doesn't work in beta
firmware):
1. Setup PC with static IP "192.168.0.66/24" and tftp server.
2. Change "*-factory" image filename to "WR942v1_recovery.bin" and make
it available to download from your tftp server.
3. Press "reset" button and power up the router, wait till "WPS" LED
turns on.
Flash instruction under U-Boot, using UART (can be done only with
preinstalled UART-enabled U-Boot version!):
1. Use "tpl" to stop autobooting and obtain U-Boot CLI access.
2. Setup ip addresses for U-Boot and your tftp server.
3. Issue below commands:
tftp 0x81000000 lede-ar71xx-generic-tl-wr942n-v1-sysupgrade.bin
erase 0x9f020000 +$filesize
cp.b 0x81000000 0x9f020000 $filesize
reset
Signed-off-by: Serg Studzinskii <serguzhg@gmail.com>
[minor code style fixes, extended commit message]
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
Use "GL.iNet" as vendor name (based on information from the vendor, this
is registered name of the company) and align model names with official
website.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
Most of the custom Build/* functions in ar71xx target are rarely used by
image building code for devices from more than one subtarget. As they
don't need to be always included, move them to corresponding *.mk files.
Signed-off-by: Piotr Dymacz <pepe2k@gmail.com>
ag71xx_ethtool_set_ringparam() will return an uninitialized value on
success.
Found-by: Coverity Scan #1330877
Signed-off-by: Alexander Couzens <lynxis@fe80.eu>
Instead of bit banging SPI to talk to the GPIO chip, use the hardware
led controllers intended for controlling the LEDs.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Fixes the following security vulnerabilities:
CVE-2017-8890
The inet_csk_clone_lock function in net/ipv4/inet_connection_sock.c in the
Linux kernel through 4.10.15 allows attackers to cause a denial of service
(double free) or possibly have unspecified other impact by leveraging use
of the accept system call.
CVE-2017-9074
The IPv6 fragmentation implementation in the Linux kernel through 4.11.1
does not consider that the nexthdr field may be associated with an invalid
option, which allows local users to cause a denial of service (out-of-bounds
read and BUG) or possibly have unspecified other impact via crafted socket
and send system calls.
CVE-2017-9075
The sctp_v6_create_accept_sk function in net/sctp/ipv6.c in the Linux kernel
through 4.11.1 mishandles inheritance, which allows local users to cause a
denial of service or possibly have unspecified other impact via crafted
system calls, a related issue to CVE-2017-8890.
CVE-2017-9076
The dccp_v6_request_recv_sock function in net/dccp/ipv6.c in the Linux
kernel through 4.11.1 mishandles inheritance, which allows local users to
cause a denial of service or possibly have unspecified other impact via
crafted system calls, a related issue to CVE-2017-8890.
CVE-2017-9077
The tcp_v6_syn_recv_sock function in net/ipv6/tcp_ipv6.c in the Linux kernel
through 4.11.1 mishandles inheritance, which allows local users to cause a
denial of service or possibly have unspecified other impact via crafted
system calls, a related issue to CVE-2017-8890.
CVE-2017-9242
The __ip6_append_data function in net/ipv6/ip6_output.c in the Linux kernel
through 4.11.3 is too late in checking whether an overwrite of an skb data
structure may occur, which allows local users to cause a denial of service
(system crash) via crafted system calls.
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-8890
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9074
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9075
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9076
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9077
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9242
Ref: https://www.kernel.org/pub/linux/kernel/v4.x/ChangeLog-4.9.31
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
Fixes the following security vulnerabilities:
CVE-2017-8890
The inet_csk_clone_lock function in net/ipv4/inet_connection_sock.c in the
Linux kernel through 4.10.15 allows attackers to cause a denial of service
(double free) or possibly have unspecified other impact by leveraging use
of the accept system call.
CVE-2017-9074
The IPv6 fragmentation implementation in the Linux kernel through 4.11.1
does not consider that the nexthdr field may be associated with an invalid
option, which allows local users to cause a denial of service (out-of-bounds
read and BUG) or possibly have unspecified other impact via crafted socket
and send system calls.
CVE-2017-9075
The sctp_v6_create_accept_sk function in net/sctp/ipv6.c in the Linux kernel
through 4.11.1 mishandles inheritance, which allows local users to cause a
denial of service or possibly have unspecified other impact via crafted
system calls, a related issue to CVE-2017-8890.
CVE-2017-9076
The dccp_v6_request_recv_sock function in net/dccp/ipv6.c in the Linux
kernel through 4.11.1 mishandles inheritance, which allows local users to
cause a denial of service or possibly have unspecified other impact via
crafted system calls, a related issue to CVE-2017-8890.
CVE-2017-9077
The tcp_v6_syn_recv_sock function in net/ipv6/tcp_ipv6.c in the Linux kernel
through 4.11.1 mishandles inheritance, which allows local users to cause a
denial of service or possibly have unspecified other impact via crafted
system calls, a related issue to CVE-2017-8890.
CVE-2017-9242
The __ip6_append_data function in net/ipv6/ip6_output.c in the Linux kernel
through 4.11.3 is too late in checking whether an overwrite of an skb data
structure may occur, which allows local users to cause a denial of service
(system crash) via crafted system calls.
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-8890
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9074
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9075
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9076
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9077
Ref: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-9242
Ref: https://www.kernel.org/pub/linux/kernel/v4.x/ChangeLog-4.4.71
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
CONFIG_SG_POOL symbol is selected only by CONFIG_SCSI, since the last
one is disabled by default then disable CONFIG_SG_POOL by default too.
And explicitly enable it only for platforms that use CONFIG_SCSI.
Signed-off-by: Sergey Ryazanov <ryazanov.s.a@gmail.com>
Add HAVE_IRQ_EXIT_ON_IRQ_STACK kernel configuration symbol that was
missed during backporting separate IRQ stack for MIPS from upstream.
Signed-off-by: Sergey Ryazanov <ryazanov.s.a@gmail.com>