This patch adds support for the Linksys EA7500 V1 router.
Specification:
- CPU: Qualcomm IPQ8064
- RAM: 256MB
- Flash: NAND 128MB
- WiFi: QCA9982 an+ac + QCA9983 bgn
- Ethernet: 5 GBE Ports (WAN+ 4xLAN) (QCA8337)
- USB: 1x USB 3.0 1x USB2.0
- Serial console: RJ-45 115200 8n1 (1V8 Voltage level)
- 2 Buttons
- 1 LED
Known issues:
- Some devices won't flash via web gui
Installation:
- Newer stock images doesn't allow to install custom firmware.
- Please downgrade software to 1.1.2 version. Official firmware:
https://downloads.linksys.com/downloads/firmware/FW_EA7500_1.1.2.172843_prod.gpg.img
- Do it two times to downgrade all stored images.
- Apply factory image via web-gui.
Serial + TFTP method:
- downgrade to 1.1.2 two times
- connect ehternet and serial cable
- set ip address of tftp server to 192.168.1.254
- put openwrt factory image to tftp folder and rename it to macan.bin
- stop device while booting in u-boot
- run command: "run flashimg"
- run command: "setenv boot_part 1"
- run command "saveenv"
- reset
Back to stock:
- Please use old non-gpg image like this 1.1.2:
https://downloads.linksys.com/downloads/firmware/FW_EA7500_1.1.2.172843_prod.img
- ssh to router and copy image to tmp
- use sysupgrade -n -F
Tested by github users: @jack338c and @grzesiczek1
Signed-off-by: Pawel Dembicki <paweldembicki@gmail.com>
[removed i2c4_pins, mdio0_pins, nand_pins, rgmii2_pins from DTSI]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
This commit made the following changes to sync all bootcount scripts:
1. use boot() instead of start()
This script only needs to be executed once when boot is complete.
use boot() to make this explicit.
2. drop sourcing of /lib/functions.sh
This is aready done in /etc/rc.common.
3. ramips: replace board name checking with a case
Signed-off-by: Chuanhong Guo <gch981213@gmail.com>
Consistently handle boot-count reset and upgrade across
ipq40xx, ipq806x, kirkwood, mvebu
Dual-firmware devices often utilize a specific MTD partition
to record the number of times the boot loader has initiated boot.
Most of these devices are NAND, typically with a 2k erase size.
When this code was ported to the ipq40xx platform, the device in hand
used NOR for this partition, with a 16-byte "record" size. As the
implementation of `mtd resetbc` is by-platform, the hard-coded nature
of this change prevented proper operation of a NAND-based device.
* Unified the "NOR" variant with the rest of the Linksys variants
* Added logging to indicate success and failure
* Provided a meaningful return value for scripting
* "Protected" the use of `mtd resetbc` in start-up scripts so that
failure does not end the boot sequence
* Moved Linksys-specific actions into common `/etc/init.d/bootcount`
For upgrade, these devices need to determine which partition to flash,
as well as set certain U-Boot envirnment variables to change the next
boot to the newly flashed version.
* Moved upgrade-related environment changes out of bootcount
* Combined multiple flashes of environment into single one
* Current-partition detection now handles absence of `boot_part`
Runtime-tested: Linksys EA8300
Signed-off-by: Jeff Kletsky <git-commits@allycomm.com>
Signed-off-by: Christian Lamparter <chunkeey@gmail.com>
[checkpatch.pl fixes, traded split strings for 80+ chars per line]
Use the generic board detection method:
- Board name: First compatible string from the device tree
- Board model: Model property from the device tree
Change occurrences of board name in userspace by the compatible
string, and removed target specific board detection script
Replace the definition of SUPPORTED_DEVICES in Device/Default
to extract the dt compatible string from each device definition.
Additionally, for devices supported by lede-17.01, append
the value of BOARD_NAME to SUPPORTED_DEVICES in the device
definition.
Signed-off-by: Luis Araneda <luaraneda@gmail.com>