On brcm47xx boards, the model ID is the combination of the "boardtype" nvram
variable and an optional supplemental "boardnum" variable while the human
readable model name is usually exposed in the "machine" field of the
/proc/cpuinfo file.
Move the extraction of the board nvram variables and model name string into
the 01_sysinfo file and rework the 01_detect board configuration script to
solely use the prepared sysinfo values without performing own detection
logic.
As a consequence, we can drop the ucidef_set_board_id() and
ucidef_set_model_name() invocations in favor to the generic behaviour
which copies the /tmp/sysinfo/{board_name,model} values into the board.json
"id" and "name" fields respectively.
Since "01_detect" only contains network configuration logic after this
change, move it to "01_network" and rename the contained "detect_by_xxx"
functions to "configure_by_xxx" instead, to avoid potential confusion.
Fixes FS#1576
Acked-by: Rafał Miłecki <rafal@milecki.pl>
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
(cherry picked from commit d7d10f2c1e)
This reverts commit 31e9445b7e.
"Linksys E1200 V1" is not a valid board name, as the brcm47xx arch code
can not detect this device. Stefan Lippers-Hollmann also found a typo in
this patch "cybetran" instead of "cybertan".
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
The generic preinit code is now able to setup network and switch vlan settings
from the /etc/board.json file, therefor drop the target specific code.
Fixes FS#790.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
Extracting TRX to separated file in /tmp/ requires extra RAM which may
not be available on some chepaer devices. Instead of that lets pass a
proper extracting command to the default_do_upgrade.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 45901
This makes sysupgrade reject firmware images for different devices.
Right now only support for 2 sample devices is implemented.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 45170
This will allow simple sysupgrade-s including simpler reverting to the
original firmware.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 43799
[base-files] shell-scripting: fix wrong usage of '==' operator
normally the '==' is used for invoking a regex parser and is a bashism.
all of the fixes just want to compare a string. the used busybox-ash
will silently "ignore" this mistake, but make it portable/clean at least.
this patch does not change the behavior/logic of the scripts.
Signed-off-by: Bastian Bittorf <bittorf@bluebottle.com>
SVN-Revision: 42911
ARGC is a 'C-ism', but not known/valid in shell-syntax - insert the correct
var $# (=number of args) here. under normal conditions this had no impact,
but we should at least correct it. the error was observable like this:
root@box:~ [ -e "/etc/functions.sh" ] && . /etc/functions.sh
root@box:~ [ -e "/lib/functions.sh" ] && . /lib/functions.sh
root@box:~ . /lib/upgrade/platform.sh
root@box:~ . /lib/upgrade/common.sh
root@box:~ platform_check_image /tmp/myfirmware.bin
ash: bad number
root@box:~ echo $?
0
Signed-off-by: Bastian Bittorf <bittorf@bluebottle.com>
SVN-Revision: 40915
Remove the code used on the old switch driver.
The Ethernet drive is loaded as a module and needs some time to get up
therefor we added some wait function.
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
SVN-Revision: 39254
Some time ago, after switching to the mainline bcm47xxpart driver
following patch has been applied:
commit 03cef8725d2062335ffc3de50fc037b294fd458c
Author: hauke <hauke@3c298f89-4303-0410-b956-a3cf2f4a3e73>
Date: Sat Apr 6 22:22:26 2013 +0000
brcm47xx: use old partition names again for kernel 3.8
This fixes sysupgrade. The partition names are used all over the Internet in various howtos.
Thank you russell for spotting this problem.
I propose to revert this change and make sysupgrade use "firmware"
instead. This makes brcm47xx compatible with widely used ar71xx and
after all "firmware" sounds like a much better name for... the firmware.
This change doesn't affect "sysupgrade" usage, because it never takes a
partition name as a parameter. This change only affects users using mtd
tool directly. Hopefully there are not many howtos using "mtd" command.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 38973
This fixes some problems with the switch handling
* It now send the messages again to indicate a button for failsafe mode should be pressed
* it does not leak packages between wan and lan any more
* the switch works again in normal mode
The Ethernet connection has to be up when the switch driver switch-robo
is insmoded therefor we just do it again.
Explicitly set enable_vlan to prevent leaking packages.
This should close#13869, #13868 and #13716
SVN-Revision: 37286
The Broadcom switch driver says that vlan0 should not be used with any switch other than bcm5325.
This makes OpenWrt always use vlan1 and vlan2 instead.
SVN-Revision: 35704
Adds specification of the correct cpu_port for Linksys E3000V1 and WRT610NV2
in /lib/preinit/05_init_interfaces_brcm. The list of devices will need to
be expanded. Is there a way to determine the correct cpu_port to use in a
generic sense; for instance, if "/proc/switch/eth0/port/8" exists, or if
"/sys/class/net/eth0/device/driver/module/drivers/bcma:bgmac" exists? Could
a similar method be used in "/etc/init.d/netconfig"?
Signed-off-by: Nathan Hintz <nlhintz@hotmail.com>
SVN-Revision: 35491
This Ethernet driver is in early development stage and still has some problems.
This was working on my bcm4716 based device.
Thanks to Rafał Miłecki <zajec5@gmail.com> for writing this driver.
SVN-Revision: 34995
The behaviour of calling 'mount' differed depending on whether it called
the busybox-mount, the mount of util-linux, the mount defined in
/lib/functions.sh and /lib/functions/boot.sh
/etc/preinit even included /lib/functions.sh and /lib/functions/boot.sh,
both re-defining 'mount'.
SVN-Revision: 34792
Sometimes the port 0 was the WAN port or there could be some device
where the port 0 is not wired to an actual Ethernet port. Now telnet in
failsafe will listen on all ports of the switch so user do not have to
search for the correct port any more. This change will make the switch
leak traffic between the WAN and the LAN port, but you should not use
failsafe while connected to a untrusted network.
SVN-Revision: 33544