mirror of
https://github.com/openwrt/openwrt.git
synced 2024-12-19 05:38:00 +00:00
mediatek: fix pwn fan settings for sinovoip bpi-r3
Popular bpi-r3 pwm fans like this one
https://www.amazon.com/youyeetoo-Barebone-Fan-BPI-R3-Integrated/dp/B0CCCTY8PS
will not work properly with current openwrt-23.05/24.10 firmware.
Trying different pwm setting
echo $value > /sys/devices/platform/pwm-fan/hwmon/hwmon1/pwm1
I found:
pwm1 value fan rotation speed cpu temperature notes
-----------------------------------------------------------------
0 maximal 31.5 Celsius too noisy
40 optimal 35.2 Celsius no noise hearable
95 minimal
above 95 does not rotate 55.5 Celsius
-----------------------------------------------------------------
At the moment we have following cooling levels:
cooling-levels = <255 96 0>;
for cpu-active-high, cpu-active-medium and cpu-active-low modes correspondingly.
Thus only cpu-active-high and cpu-active-low are usable. I think this is wrong.
This patch fixes cpu-active-medium settings for bpi-r3 board.
PS: I know, the patch is not ideal as it can break pwm fan for some users.
There are some peoples that use handmade cooling solutions, but:
* discussed cooler is the only 'official' pwm cooler for bpi-r3
available on the market.
* most peoples will use passive cooling available on the market or
the discussed cooler.
* the pwm-fan dts section was added before the official cooler
appears on the market.
Thus it should not be a lot of harm from this fix.
Signed-off-by: Mikhail Kshevetskiy <mikhail.kshevetskiy@gmail.com>
Link: https://github.com/openwrt/openwrt/pull/16974
Signed-off-by: Robert Marko <robimarko@gmail.com>
(cherry picked from commit 3467ea905b
)
Link: https://github.com/openwrt/openwrt/pull/17097
Signed-off-by: Petr Štetiar <ynezz@true.cz>
This commit is contained in:
parent
77de80d9db
commit
f93bba30d7
@ -0,0 +1,11 @@
|
|||||||
|
--- a/arch/arm64/boot/dts/mediatek/mt7986a-bananapi-bpi-r3.dts
|
||||||
|
+++ b/arch/arm64/boot/dts/mediatek/mt7986a-bananapi-bpi-r3.dts
|
||||||
|
@@ -46,7 +46,7 @@
|
||||||
|
compatible = "pwm-fan";
|
||||||
|
#cooling-cells = <2>;
|
||||||
|
/* cooling level (0, 1, 2) - pwm inverted */
|
||||||
|
- cooling-levels = <255 96 0>;
|
||||||
|
+ cooling-levels = <255 40 0>;
|
||||||
|
pwms = <&pwm 0 10000>;
|
||||||
|
status = "okay";
|
||||||
|
};
|
Loading…
Reference in New Issue
Block a user