mirror of
https://github.com/openwrt/openwrt.git
synced 2025-02-20 17:32:57 +00:00
mt7622: remove 300 MHz from dts
Due to the bug described here[1], remove the 300 MHz clock to avoid a low voltage condition that can cause a hang when rebooting the RT3200/E8450. This solution is probably better than the script-based work-around[2]. 1. https://forum.openwrt.org/t/belkin-rt3200-linksys-e8450-wifi-ax-discussion/94302/1490 2. https://github.com/openwrt/openwrt/pull/5025 Signed-off-by: John Audia <therealgraysky@proton.me> Tested-by: Rui Salvaterra <rsalvaterra@gmail.com> Tested-by: John Audia <therealgraysky@proton.me>
This commit is contained in:
parent
79af0593a3
commit
d0d6b8e183
@ -0,0 +1,25 @@
|
||||
--- a/arch/arm64/boot/dts/mediatek/mt7622.dtsi
|
||||
+++ b/arch/arm64/boot/dts/mediatek/mt7622.dtsi
|
||||
@@ -23,11 +23,17 @@
|
||||
cpu_opp_table: opp-table {
|
||||
compatible = "operating-points-v2";
|
||||
opp-shared;
|
||||
- opp-300000000 {
|
||||
- opp-hz = /bits/ 64 <300000000>;
|
||||
- opp-microvolt = <950000>;
|
||||
- };
|
||||
-
|
||||
+ /* Due to the bug described at the link below, remove the 300 MHz clock to avoid a low
|
||||
+ * voltage condition that can cause a hang when rebooting the RT3200/E8450.
|
||||
+ *
|
||||
+ * https://forum.openwrt.org/t/belkin-rt3200-linksys-e8450-wifi-ax-discussion/94302/1490
|
||||
+ *
|
||||
+ * opp-300000000 {
|
||||
+ * opp-hz = /bits/ 64 <300000000>;
|
||||
+ * opp-microvolt = <950000>;
|
||||
+ * };
|
||||
+ *
|
||||
+ */
|
||||
opp-437500000 {
|
||||
opp-hz = /bits/ 64 <437500000>;
|
||||
opp-microvolt = <1000000>;
|
Loading…
x
Reference in New Issue
Block a user