qualcommax: ipq807x: 301w: correct PHY mode for AQR

Interfaces that have AQR-s attached to them are using USXGMII and not just
the default SGMII.
This was fine until SSDK added some sanity checking and now on Qnap 301W it
would fail with:
[   24.740197] nss-dp 3a001800.dp5 10g-1 (uninitialized): failed to connect to phy device
[   24.740264] nss-dp: probe of 3a001800.dp5 failed with error -14

So, lets fix 10G AQR ports by declaring the correct PHY mode.

Signed-off-by: Robert Marko <robimarko@gmail.com>
This commit is contained in:
Robert Marko 2024-02-17 13:41:36 +01:00
parent dadad6bb73
commit b38a1d6c65

View File

@ -485,12 +485,14 @@
&dp5 {
status = "okay";
qcom,mactype = <1>;
phy-mode = "usxgmii";
phy-handle = <&aqr113c_8>;
label = "10g-1";
};
&dp6_syn {
status = "okay";
phy-mode = "usxgmii";
phy-handle = <&aqr113c_0>;
label = "10g-2";
};