mirror of
https://github.com/openwrt/openwrt.git
synced 2024-12-20 06:08:08 +00:00
n810bm: Set minimum voltage threshold to 3200
SVN-Revision: 25433
This commit is contained in:
parent
2d3ed6dc2d
commit
970b4c6a72
@ -41,8 +41,8 @@ Index: linux-2.6.37/drivers/cbus/Makefile
|
||||
Index: linux-2.6.37/drivers/cbus/n810bm_main.c
|
||||
===================================================================
|
||||
--- /dev/null 1970-01-01 00:00:00.000000000 +0000
|
||||
+++ linux-2.6.37/drivers/cbus/n810bm_main.c 2011-02-09 13:47:23.831144291 +0100
|
||||
@@ -0,0 +1,1169 @@
|
||||
+++ linux-2.6.37/drivers/cbus/n810bm_main.c 2011-02-09 19:05:18.435536304 +0100
|
||||
@@ -0,0 +1,1168 @@
|
||||
+/*
|
||||
+ * Nokia n810 battery management
|
||||
+ *
|
||||
@ -86,7 +86,7 @@ Index: linux-2.6.37/drivers/cbus/n810bm_main.c
|
||||
+#define N810BM_PMM_BLOCK_SIZE 0x600
|
||||
+
|
||||
+#define N810BM_CHECK_INTERVAL (HZ * 2)
|
||||
+#define N810BM_MIN_VOLTAGE_THRES 3300 /* Absolute minimum voltage threshold */
|
||||
+#define N810BM_MIN_VOLTAGE_THRES 3200 /* Absolute minimum voltage threshold */
|
||||
+
|
||||
+
|
||||
+/* RETU_ADC_BSI
|
||||
@ -612,7 +612,6 @@ Index: linux-2.6.37/drivers/cbus/n810bm_main.c
|
||||
+ struct n810bm, periodic_check_work);
|
||||
+ u16 status;
|
||||
+ bool battery_was_present, charger_was_present;
|
||||
+ bool force_charge = 0;
|
||||
+ int mv;
|
||||
+
|
||||
+ mutex_lock(&bm->mutex);
|
||||
@ -646,23 +645,23 @@ Index: linux-2.6.37/drivers/cbus/n810bm_main.c
|
||||
+ bm->charger_present ? "plugged in" : "removed");
|
||||
+ }
|
||||
+
|
||||
+ if (bm->battery_present && !lipocharge_is_charging(&bm->charger)) {
|
||||
+ if ((bm->battery_present && !bm->charger_present) ||
|
||||
+ !n810bm_known_battery_present(bm)){
|
||||
+ /* We're draining the battery */
|
||||
+ mv = n810bm_measure_batt_voltage(bm);
|
||||
+ if (mv < 0)
|
||||
+ n810bm_emergency(bm, "check timer: Failed to measure");
|
||||
+ if (!bm->charger_present) {
|
||||
+ if (mv < N810BM_MIN_VOLTAGE_THRES) {
|
||||
+ n810bm_emergency(bm, "check timer: "
|
||||
+ "Minimum voltage threshold reached");
|
||||
+ }
|
||||
+ force_charge = 1;
|
||||
+ if (mv < 0) {
|
||||
+ n810bm_emergency(bm,
|
||||
+ "check: Failed to measure voltage");
|
||||
+ }
|
||||
+ if (mv < N810BM_MIN_VOLTAGE_THRES) {
|
||||
+ n810bm_emergency(bm,
|
||||
+ "check: Minimum voltage threshold reached");
|
||||
+ }
|
||||
+ }
|
||||
+
|
||||
+ if (bm->charger_present && n810bm_known_battery_present(bm)) {
|
||||
+ /* Known battery and charger are connected */
|
||||
+ if (bm->charger_enabled || force_charge) {
|
||||
+ if (bm->charger_enabled) {
|
||||
+ /* Charger is enabled */
|
||||
+ if (!lipocharge_is_charging(&bm->charger)) {
|
||||
+ //TODO start charging, if battery is below some threshold
|
||||
|
Loading…
Reference in New Issue
Block a user