2022-10-05 17:44:42 +00:00
|
|
|
From cd47d86ab09f1f3ec5c86441d4fe95e0cf597c06 Mon Sep 17 00:00:00 2001
|
|
|
|
From: Daniel Golle <daniel@makrotopia.org>
|
|
|
|
Date: Tue, 13 Sep 2022 00:56:24 +0100
|
|
|
|
Subject: [PATCH] thermal/drivers/mediatek: add support for MT7986 and MT7981
|
|
|
|
|
|
|
|
Add support for V3 generation thermal found in MT7986 and MT7981 SoCs.
|
|
|
|
|
|
|
|
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
|
|
|
|
---
|
|
|
|
drivers/thermal/mtk_thermal.c | 202 +++++++++++++++++++++++++++++++++-
|
|
|
|
1 file changed, 198 insertions(+), 4 deletions(-)
|
|
|
|
|
|
|
|
--- a/drivers/thermal/mtk_thermal.c
|
|
|
|
+++ b/drivers/thermal/mtk_thermal.c
|
|
|
|
@@ -150,6 +150,21 @@
|
|
|
|
#define CALIB_BUF1_VALID_V2(x) (((x) >> 4) & 0x1)
|
|
|
|
#define CALIB_BUF1_O_SLOPE_SIGN_V2(x) (((x) >> 3) & 0x1)
|
|
|
|
|
|
|
|
+/*
|
|
|
|
+ * Layout of the fuses providing the calibration data
|
|
|
|
+ * These macros could be used for MT7981 and MT7986.
|
|
|
|
+ */
|
|
|
|
+#define CALIB_BUF0_ADC_GE_V3(x) (((x) >> 0) & 0x3ff)
|
|
|
|
+#define CALIB_BUF0_ADC_OE_V3(x) (((x) >> 10) & 0x3ff)
|
|
|
|
+#define CALIB_BUF0_DEGC_CALI_V3(x) (((x) >> 20) & 0x3f)
|
|
|
|
+#define CALIB_BUF0_O_SLOPE_V3(x) (((x) >> 26) & 0x3f)
|
|
|
|
+#define CALIB_BUF1_VTS_TS1_V3(x) (((x) >> 0) & 0x1ff)
|
|
|
|
+#define CALIB_BUF1_VTS_TS2_V3(x) (((x) >> 21) & 0x1ff)
|
|
|
|
+#define CALIB_BUF1_VTS_TSABB_V3(x) (((x) >> 9) & 0x1ff)
|
|
|
|
+#define CALIB_BUF1_VALID_V3(x) (((x) >> 18) & 0x1)
|
|
|
|
+#define CALIB_BUF1_O_SLOPE_SIGN_V3(x) (((x) >> 19) & 0x1)
|
|
|
|
+#define CALIB_BUF1_ID_V3(x) (((x) >> 20) & 0x1)
|
|
|
|
+
|
|
|
|
enum {
|
|
|
|
VTS1,
|
|
|
|
VTS2,
|
|
|
|
@@ -163,6 +178,7 @@ enum {
|
|
|
|
enum mtk_thermal_version {
|
|
|
|
MTK_THERMAL_V1 = 1,
|
|
|
|
MTK_THERMAL_V2,
|
|
|
|
+ MTK_THERMAL_V3,
|
|
|
|
};
|
|
|
|
|
|
|
|
/* MT2701 thermal sensors */
|
|
|
|
@@ -245,6 +261,27 @@ enum mtk_thermal_version {
|
|
|
|
/* The calibration coefficient of sensor */
|
|
|
|
#define MT8183_CALIBRATION 153
|
|
|
|
|
|
|
|
+/* AUXADC channel 11 is used for the temperature sensors */
|
|
|
|
+#define MT7986_TEMP_AUXADC_CHANNEL 11
|
|
|
|
+
|
|
|
|
+/* The total number of temperature sensors in the MT7986 */
|
|
|
|
+#define MT7986_NUM_SENSORS 1
|
|
|
|
+
|
|
|
|
+/* The number of banks in the MT7986 */
|
|
|
|
+#define MT7986_NUM_ZONES 1
|
|
|
|
+
|
|
|
|
+/* The number of sensing points per bank */
|
|
|
|
+#define MT7986_NUM_SENSORS_PER_ZONE 1
|
|
|
|
+
|
|
|
|
+/* MT7986 thermal sensors */
|
|
|
|
+#define MT7986_TS1 0
|
|
|
|
+
|
|
|
|
+/* The number of controller in the MT7986 */
|
|
|
|
+#define MT7986_NUM_CONTROLLER 1
|
|
|
|
+
|
|
|
|
+/* The calibration coefficient of sensor */
|
|
|
|
+#define MT7986_CALIBRATION 165
|
|
|
|
+
|
|
|
|
struct mtk_thermal;
|
|
|
|
|
|
|
|
struct thermal_bank_cfg {
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -386,6 +423,14 @@ static const int mt7622_mux_values[MT762
|
2022-10-05 17:44:42 +00:00
|
|
|
static const int mt7622_vts_index[MT7622_NUM_SENSORS] = { VTS1 };
|
|
|
|
static const int mt7622_tc_offset[MT7622_NUM_CONTROLLER] = { 0x0, };
|
|
|
|
|
|
|
|
+/* MT7986 thermal sensor data */
|
|
|
|
+static const int mt7986_bank_data[MT7986_NUM_SENSORS] = { MT7986_TS1, };
|
|
|
|
+static const int mt7986_msr[MT7986_NUM_SENSORS_PER_ZONE] = { TEMP_MSR0, };
|
|
|
|
+static const int mt7986_adcpnp[MT7986_NUM_SENSORS_PER_ZONE] = { TEMP_ADCPNP0, };
|
|
|
|
+static const int mt7986_mux_values[MT7986_NUM_SENSORS] = { 0, };
|
|
|
|
+static const int mt7986_vts_index[MT7986_NUM_SENSORS] = { VTS1 };
|
|
|
|
+static const int mt7986_tc_offset[MT7986_NUM_CONTROLLER] = { 0x0, };
|
|
|
|
+
|
|
|
|
/*
|
|
|
|
* The MT8173 thermal controller has four banks. Each bank can read up to
|
|
|
|
* four temperature sensors simultaneously. The MT8173 has a total of 5
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -549,6 +594,30 @@ static const struct mtk_thermal_data mt8
|
2022-10-05 17:44:42 +00:00
|
|
|
.version = MTK_THERMAL_V1,
|
|
|
|
};
|
|
|
|
|
|
|
|
+/*
|
|
|
|
+ * MT7986 uses AUXADC Channel 11 for raw data access.
|
|
|
|
+ */
|
|
|
|
+static const struct mtk_thermal_data mt7986_thermal_data = {
|
|
|
|
+ .auxadc_channel = MT7986_TEMP_AUXADC_CHANNEL,
|
|
|
|
+ .num_banks = MT7986_NUM_ZONES,
|
|
|
|
+ .num_sensors = MT7986_NUM_SENSORS,
|
|
|
|
+ .vts_index = mt7986_vts_index,
|
|
|
|
+ .cali_val = MT7986_CALIBRATION,
|
|
|
|
+ .num_controller = MT7986_NUM_CONTROLLER,
|
|
|
|
+ .controller_offset = mt7986_tc_offset,
|
|
|
|
+ .need_switch_bank = true,
|
|
|
|
+ .bank_data = {
|
|
|
|
+ {
|
|
|
|
+ .num_sensors = 1,
|
|
|
|
+ .sensors = mt7986_bank_data,
|
|
|
|
+ },
|
|
|
|
+ },
|
|
|
|
+ .msr = mt7986_msr,
|
|
|
|
+ .adcpnp = mt7986_adcpnp,
|
|
|
|
+ .sensor_mux_values = mt7986_mux_values,
|
|
|
|
+ .version = MTK_THERMAL_V3,
|
|
|
|
+};
|
|
|
|
+
|
|
|
|
/**
|
|
|
|
* raw_to_mcelsius - convert a raw ADC value to mcelsius
|
|
|
|
* @mt: The thermal controller
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -603,6 +672,22 @@ static int raw_to_mcelsius_v2(struct mtk
|
2022-10-05 17:44:42 +00:00
|
|
|
return (format_2 - tmp) * 100;
|
|
|
|
}
|
|
|
|
|
|
|
|
+static int raw_to_mcelsius_v3(struct mtk_thermal *mt, int sensno, s32 raw)
|
|
|
|
+{
|
|
|
|
+ s32 tmp;
|
|
|
|
+
|
|
|
|
+ if (raw == 0)
|
|
|
|
+ return 0;
|
|
|
|
+
|
|
|
|
+ raw &= 0xfff;
|
|
|
|
+ tmp = 100000 * 15 / 16 * 10000;
|
|
|
|
+ tmp /= 4096 - 512 + mt->adc_ge;
|
|
|
|
+ tmp /= 1490;
|
2022-10-31 19:50:40 +00:00
|
|
|
+ tmp *= raw - mt->vts[sensno] - 2900 - mt->adc_oe + 512;
|
2022-10-05 17:44:42 +00:00
|
|
|
+
|
|
|
|
+ return mt->degc_cali * 500 - tmp;
|
|
|
|
+}
|
|
|
|
+
|
|
|
|
/**
|
|
|
|
* mtk_thermal_get_bank - get bank
|
|
|
|
* @bank: The bank
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -659,9 +744,12 @@ static int mtk_thermal_bank_temperature(
|
2022-10-05 17:44:42 +00:00
|
|
|
if (mt->conf->version == MTK_THERMAL_V1) {
|
|
|
|
temp = raw_to_mcelsius_v1(
|
|
|
|
mt, conf->bank_data[bank->id].sensors[i], raw);
|
|
|
|
- } else {
|
|
|
|
+ } else if (mt->conf->version == MTK_THERMAL_V2) {
|
|
|
|
temp = raw_to_mcelsius_v2(
|
|
|
|
mt, conf->bank_data[bank->id].sensors[i], raw);
|
|
|
|
+ } else {
|
|
|
|
+ temp = raw_to_mcelsius_v3(
|
|
|
|
+ mt, conf->bank_data[bank->id].sensors[i], raw);
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -887,6 +975,26 @@ static int mtk_thermal_extract_efuse_v2(
|
2022-10-05 17:44:42 +00:00
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
+static int mtk_thermal_extract_efuse_v3(struct mtk_thermal *mt, u32 *buf)
|
|
|
|
+{
|
|
|
|
+ if (!CALIB_BUF1_VALID_V3(buf[1]))
|
|
|
|
+ return -EINVAL;
|
|
|
|
+
|
|
|
|
+ mt->adc_oe = CALIB_BUF0_ADC_OE_V3(buf[0]);
|
|
|
|
+ mt->adc_ge = CALIB_BUF0_ADC_GE_V3(buf[0]);
|
|
|
|
+ mt->degc_cali = CALIB_BUF0_DEGC_CALI_V3(buf[0]);
|
|
|
|
+ mt->o_slope = CALIB_BUF0_O_SLOPE_V3(buf[0]);
|
|
|
|
+ mt->vts[VTS1] = CALIB_BUF1_VTS_TS1_V3(buf[1]);
|
|
|
|
+ mt->vts[VTS2] = CALIB_BUF1_VTS_TS2_V3(buf[1]);
|
|
|
|
+ mt->vts[VTSABB] = CALIB_BUF1_VTS_TSABB_V3(buf[1]);
|
|
|
|
+ mt->o_slope_sign = CALIB_BUF1_O_SLOPE_SIGN_V3(buf[1]);
|
|
|
|
+
|
|
|
|
+ if (CALIB_BUF1_ID_V3(buf[1]) == 0)
|
|
|
|
+ mt->o_slope = 0;
|
|
|
|
+
|
|
|
|
+ return 0;
|
|
|
|
+}
|
|
|
|
+
|
|
|
|
static int mtk_thermal_get_calibration_data(struct device *dev,
|
|
|
|
struct mtk_thermal *mt)
|
|
|
|
{
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -897,6 +1005,7 @@ static int mtk_thermal_get_calibration_d
|
2022-10-05 17:44:42 +00:00
|
|
|
|
|
|
|
/* Start with default values */
|
|
|
|
mt->adc_ge = 512;
|
|
|
|
+ mt->adc_oe = 512;
|
|
|
|
for (i = 0; i < mt->conf->num_sensors; i++)
|
|
|
|
mt->vts[i] = 260;
|
|
|
|
mt->degc_cali = 40;
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -924,8 +1033,10 @@ static int mtk_thermal_get_calibration_d
|
2022-10-05 17:44:42 +00:00
|
|
|
|
|
|
|
if (mt->conf->version == MTK_THERMAL_V1)
|
|
|
|
ret = mtk_thermal_extract_efuse_v1(mt, buf);
|
|
|
|
- else
|
|
|
|
+ else if (mt->conf->version == MTK_THERMAL_V2)
|
|
|
|
ret = mtk_thermal_extract_efuse_v2(mt, buf);
|
|
|
|
+ else
|
|
|
|
+ ret = mtk_thermal_extract_efuse_v3(mt, buf);
|
|
|
|
|
|
|
|
if (ret) {
|
|
|
|
dev_info(dev, "Device not calibrated, using default calibration values\n");
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -956,6 +1067,10 @@ static const struct of_device_id mtk_the
|
2022-10-05 17:44:42 +00:00
|
|
|
.data = (void *)&mt7622_thermal_data,
|
|
|
|
},
|
|
|
|
{
|
|
|
|
+ .compatible = "mediatek,mt7986-thermal",
|
|
|
|
+ .data = (void *)&mt7986_thermal_data,
|
|
|
|
+ },
|
|
|
|
+ {
|
|
|
|
.compatible = "mediatek,mt8183-thermal",
|
|
|
|
.data = (void *)&mt8183_thermal_data,
|
|
|
|
}, {
|
2022-10-20 19:20:41 +00:00
|
|
|
@@ -1070,7 +1185,8 @@ static int mtk_thermal_probe(struct plat
|
2022-10-05 17:44:42 +00:00
|
|
|
goto err_disable_clk_auxadc;
|
|
|
|
}
|
|
|
|
|
|
|
|
- if (mt->conf->version == MTK_THERMAL_V2) {
|
|
|
|
+ if (mt->conf->version == MTK_THERMAL_V2 ||
|
|
|
|
+ mt->conf->version == MTK_THERMAL_V3) {
|
|
|
|
mtk_thermal_turn_on_buffer(apmixed_base);
|
|
|
|
mtk_thermal_release_periodic_ts(mt, auxadc_base);
|
|
|
|
}
|