61 Commits

Author SHA1 Message Date
alex-nitrokey
30236ffbaa
Delete AES keys of Nitrokey Storage after reset
If smartcard Nitrokey Storage was factory-reset, we delete AES keys on
it as well.

Explaination: After oem-factory-reset was started the AES on the Nitrokey Storage that is used for the encrypted volume and the password safe is is not usable anymore because the smart card was factory-reset. To make it usable, a user needs to delete it via Nitrokey App. By doing so, the HOTP secret is deleted as well, resulting in a bad warning in Heads. Therefore, we are resetting AES key right after factory-reset with hotp_verification
2020-06-30 18:29:42 +02:00
tlaurion
94476bb470
Merge pull request #747 from MrChromebox/factory_reset_no_tpm
oem-factory-reset: Handle non-TPM case
2020-06-28 15:26:16 -04:00
tlaurion
fab603153b
Merge pull request #646 from alex-nitrokey/custom-userinfo
Add option to choose GnuPG userinfo during OEM reset
2020-06-17 14:00:31 -04:00
Matt DeVillier
cbad9b6637
oem-factory-reset: Handle non-TPM case
Guard TPM-related bits by checking CONFIG_TPM = y

Signed-off-by: Matt DeVillier <matt.devillier@puri.sm>
2020-06-09 12:45:39 -05:00
alex-nitrokey
a16b97b6ea
Add more input validation
Based on tlaurion's work done here
ff148e4daf/initrd/bin/factory-reset-libremkey.sh (L53)
2020-03-26 15:05:51 +01:00
Matt DeVillier
83a67d2798
oem-factory-reset: fix GPG key backup filename
fix $GPG_GEN_KEY getting clobbered when using a custom password

Signed-off-by: Matt DeVillier <matt.devillier@puri.sm>
2020-02-19 16:47:51 -06:00
alex-nitrokey
f0f6e80e95
Add option to choose GnuPG userinfo during OEM reset 2020-01-02 17:29:11 +01:00
Martin Kepplinger
81df949632 oem-factory-reset: Fix description for rebooting when finished
As is in many cases in Heads, not any key will work, just Enter.

Signed-off-by: Martin Kepplinger <martin.kepplinger@puri.sm>
2019-11-26 18:10:39 +01:00
Matt DeVillier
4db6fbd51a
oem-factory-reset: enforce 8-char min on custom password
Since the custom password is used to set the GPG admin
password as well as the TPM and GPG user passwords, an
8-character minimum is required. Inform the user of this,
and validate custom password length upon entry.

Signed-off-by: Matt DeVillier <matt.devillier@puri.sm>
2019-11-25 12:44:56 -06:00
Kyle Rankin
018279b2bf
Add ability to enter custom password for OEM reset
Normally we resort to default passwords for OEM reset, however we have a
use case where it would be convenient to set a custom password instead.
This patch adds a simple prompt (that defaults to the defaults if you
hit Enter) that enables someone using the OEM reset to enter a single
password that will replace the defaults (TPM, GPG Admin, GPG User).
2019-11-18 11:31:55 -06:00
Matt DeVillier
f067d9af23
initrd/bin: add OEM Factory Reset
Add oem-factory-reset script which performs an unattended
reset and configuration of the device's TPM, GPG security token,
and boot device / boot selection.

Signed-off-by: Matt DeVillier <matt.devillier@puri.sm>
2019-08-21 17:10:23 -05:00