/v2/projects/{project_id}/links/{link_id}/start_capture ------------------------------------------------------------------------------------------------------------------------------------------ .. contents:: POST /v2/projects/**{project_id}**/links/**{link_id}**/start_capture ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Start capture on a link instance. By default we consider it as an Ethernet link Parameters ********** - **link_id**: Link UUID - **project_id**: Project UUID Response status codes ********************** - **400**: Invalid request - **201**: Capture started Input ******* .. raw:: html
Name Mandatory Type Description
capture_file_name string Read only property. The name of the capture file if capture is running
data_link_type enum Possible values: DLT_ATM_RFC1483, DLT_EN10MB, DLT_FRELAY, DLT_C_HDLC, DLT_PPP_SERIAL
Output ******* .. raw:: html
Name Mandatory Type Description
capture_file_name ['string', 'null'] Read only property. The name of the capture file if capture is running
capture_file_path ['string', 'null'] Read only property. The full path of the capture file if capture is running
capturing boolean Read only property. True if a capture running on the link
filters object Packet filter. This allow to simulate latency and errors
link_id string Link UUID
link_type enum Possible values: ethernet, serial
nodes array List of the VMS
project_id string Project UUID
suspend boolean Suspend the link