The former 'Genode::Timed_semaphore' mechanism is moved to the private
part of the two remaining users, namely dde_rump and the libc. Note
there are now two private copies of 'timed_semaphore.h'. This should be
regarded as an interim step until the use of this mechanism is removed
from both users.
This patch also cleans up the mechanism from legacy Genode API calls and
global side effects (alarm-thread singleton). The test/timed_semaphore
is now located at the libports repository as it now tests a mechanism of
the libc. The former timed_semaphore library is no more.
Fixes#3121
Since the timer and timeout handling is part of the base library (the
dynamic linker), it belongs to the base repository.
Besides moving the timer and its related infrastructure (alarm, timeout
libs, tests) to the base repository, this patch also moves the timer
from the 'drivers' subdirectory directly to 'src' and disamibuates the
timer's build locations for the various kernels. Otherwise the different
timer implementations could interfere with each other when using one
build directory with multiple kernels.
Note that this patch changes the include paths for the former os/timer,
os/alarm.h, os/duration.h, and os/timed_semaphore.h to base/.
Issue #3101
Our overall nightly test time greatly decreases when the timeouts for
the single tests are not that over-pessimistic. Using the slowest
platforms as reference, this commit reduces the test timeouts.
Ref #3027
Introduce the uplink tag:
! <config>
! <uplink label="wifi" domain="uplink">
! <uplink label="wired" domain="wired_bridge">
! <uplink domain="wired_bridge">
! <config/>
For each uplink tag, the NIC router requests a NIC session with the
corresponding label or an empty label if there is no label attribute.
These NIC sessions get attached to the domain that is set in their
uplink tag as soon as the domain appears. This means their lifetime is
not bound to the domain. Uplink NIC sessions can be safely moved from
one domain to another without being closed by reconfiguring the
corresponding domain attribute.
Attention: This may render previously valid NIC router configurations
useless. A domain named "uplink" doesn't automatically request a NIC
session anymore. To fix these configurations, just add
! <uplink domain="uplink"/>
or
! <uplink label="[LABEL]" domain="uplink"/>
as direct subtag of the <config> tag.
Issue #2840