The 'WHITESPACE' case of the _calc_len method wrongly accessed the
character before checking upper bound of the token. The problem is fixed
by switching the order of both conditions.
Fixes#3756
The former 'Genode::Timed_semaphore' mechanism is moved to the private
part of the two remaining users, namely dde_rump and the libc. Note
there are now two private copies of 'timed_semaphore.h'. This should be
regarded as an interim step until the use of this mechanism is removed
from both users.
This patch also cleans up the mechanism from legacy Genode API calls and
global side effects (alarm-thread singleton). The test/timed_semaphore
is now located at the libports repository as it now tests a mechanism of
the libc. The former timed_semaphore library is no more.
Fixes#3121
Since the timer and timeout handling is part of the base library (the
dynamic linker), it belongs to the base repository.
Besides moving the timer and its related infrastructure (alarm, timeout
libs, tests) to the base repository, this patch also moves the timer
from the 'drivers' subdirectory directly to 'src' and disamibuates the
timer's build locations for the various kernels. Otherwise the different
timer implementations could interfere with each other when using one
build directory with multiple kernels.
Note that this patch changes the include paths for the former os/timer,
os/alarm.h, os/duration.h, and os/timed_semaphore.h to base/.
Issue #3101
* In base-foc/recipes/src/ replace base-foc with base-foc-pc
* To base-foc/recipes/src add base-foc-arndale, base-foc-pbxa9
* Ensure that the correct base-foc recipe is choosen by the run module
'boot_dir/foc'