Author: Joseph Myers <joseph@codesourcery.com>
|
|
Date: 2016-10-24
|
|
|
|
Building glibc for powerpc64 with recent (2.27.51.20161012) binutils,
|
|
with multi-arch enabled, I get the error:
|
|
|
|
../sysdeps/powerpc/powerpc64/power6/memset.S: Assembler messages:
|
|
../sysdeps/powerpc/powerpc64/power6/memset.S:254: Error: operand out of range (5 is not between 0 and 1)
|
|
../sysdeps/powerpc/powerpc64/power6/memset.S:254: Error: operand out of range (128 is not between 0 and 31)
|
|
../sysdeps/powerpc/powerpc64/power6/memset.S:254: Error: missing operand
|
|
|
|
Indeed, cmpli is documented as a four-operand instruction, and looking
|
|
at nearby code it seems likely cmpldi was intended. This patch fixes
|
|
this powerpc64 code accordingly, and makes a corresponding change to
|
|
the powerpc32 code.
|
|
|
|
Note: this patch is not tested beyond verifying that the powerpc64
|
|
code builds where it failed to build before the patch. In particular,
|
|
I have not done execution testing (the systems I usually use for
|
|
testing powerpc are pre-power6 so wouldn't use this code) or tested
|
|
the powerpc32 change.
|
|
|
|
---
|
|
sysdeps/powerpc/powerpc32/power6/memset.S (memset): Use cmplwi instead of cmpli.
|
|
sysdeps/powerpc/powerpc64/power6/memset.S (memset): Use cmpldi instead of cmpli.
|
|
|
|
--- a/sysdeps/powerpc/powerpc32/power6/memset.S
|
|
+++ b/sysdeps/powerpc/powerpc32/power6/memset.S
|
|
@@ -394,7 +394,7 @@ L(cacheAlignedx):
|
|
/* A simple loop for the longer (>640 bytes) lengths. This form limits
|
|
the branch miss-predicted to exactly 1 at loop exit.*/
|
|
L(cacheAligned512):
|
|
- cmpli cr1,rLEN,128
|
|
+ cmplwi cr1,rLEN,128
|
|
blt cr1,L(cacheAligned1)
|
|
dcbz 0,rMEMP
|
|
addi rLEN,rLEN,-128
|
|
|
|
--- a/sysdeps/powerpc/powerpc64/power6/memset.S
|
|
+++ b/sysdeps/powerpc/powerpc64/power6/memset.S
|
|
@@ -251,7 +251,7 @@ L(cacheAlignedx):
|
|
/* A simple loop for the longer (>640 bytes) lengths. This form limits
|
|
the branch miss-predicted to exactly 1 at loop exit.*/
|
|
L(cacheAligned512):
|
|
- cmpli cr1,rLEN,128
|
|
+ cmpldi cr1,rLEN,128
|
|
blt cr1,L(cacheAligned1)
|
|
dcbz 0,rMEMP
|
|
addi rLEN,rLEN,-128
|