Added a new field Completed to the in-memory object FlowState.
FlowState.Completed is corresponds to flow_state=Null in the DB.
This change will save disk space.
* Introduce CordaSessionFactoryFactory interface and the H2 implememntation
* Load SessionFactoryFactory via service loader
* Add Postgres SessionFactoryFactory
* Add extraConfiguration function for SessionFactoryFactory implementations to expose special config values.
* Run serialisation tests with both in-process and out-of-process nodes.
* Add custom serialisers and whitelists to Driver's AMQPServerSerializationScheme.
* Run serialisation tests with both in-process and out-of-process nodes.
* Add custom serialisers and whitelists to Driver's AMQPServerSerializationScheme.
* Stop capturing 'FlowLogic' references in flowAsyncOperation;
Creating concrete classes removes the implicit reference to FlowLogic (as this) being included in the anonymous object
* Modify test code so that lambdas no longer get implicit references to their enclosing 'FlowLogic'
* Stop capturing 'FlowLogic' references in flowAsyncOperation;
Creating concrete classes removes the implicit reference to FlowLogic (as this) being included in the anonymous object
* Modify test code so that lambdas no longer get implicit references to their enclosing 'FlowLogic'
* CORDA-3601 Record a flow's finish time
Record a flow's finish time by updating its metadata record. It is set
in `updateCheckpoint` by checking the status of the checkpoint. If it is
`COMPLETED` it will set the `finishInstant` on the metadata object and
update it.
* CORDA-3601 Record flow finish time for all finished statuses
Update the flow finish time for the following statuses:
- COMPLETED
- KILLED
- FAILED
* CORDA-3601 Use platform clock in `DBCheckpointStorage`
* CORDA-3669 Do not execute `ExecuteAsyncOperation` multiple times
When a `FlowExternalOperation` or `FlowExternalAsyncOperation` executes
and completes a flag (`isFlowResumed`) is switched to true.
This flag was used inside of `DoRemainingWorkTransition` to decide
whether to skip over the execution of an event.
Since this flag was being switched to true when the external operation's
future completed, it was possible for _unexpected_ events to be placed
in the fiber's queue that would retrigger the
`FlowIORequest.ExecuteAsyncOperation`, that is held as the checkpoint's
next `FlowIORequest`to process.
By using the existing `StateMachineState.isTransactionTracked` (and
renaming it to `isWaitingForFuture`) we can decide to not process the
`FlowIORequest.ExecuteAsyncOperation` if it has already been called
before. This moves this code path in line with
`FlowIORequest.WaitForLedgerCommit`.
Random `DoRemainingWork` events can now be pushed to the fiber's queue
without causing the `FlowIORequest.ExecuteAsyncOperation` to execute
again.
* CORDA-3668: Prevent AttachmentURLConnection from assigning ALL_PERMISSIONS to classes inside an attachment.
* Strengthen the comment warning about AttachmentURLConnection.getPermission.
* NOTICK Increase timeouts in external operation tests
It seems these tests are timing out when they shouldn't be when running
on the CI servers.
To resolve this, the timeouts of `getOrThrow` calls have been increased
to a minute.
Reliance on timeouts has also been reduced through using locks. This
should speed up tests that don't need to wait for the timeout anymore to
progress.
* NOTICK Remove hospital checking code
* NOTICK Change locking code
* CORDA-3596 Record flow metadata
Record flow metadata during the zero'th checkpoint that occurs before
calling the flow's `call` function.
This required adding an RPC call's arguments to the `InvocationContext`
that gets created. These arguments are then accessible within the
statemachine and from the `Checkpoint` class. The arguments are then
extracted when recording a flow's metadata inside of
`DBCheckpointStorage`.
Updated the size of the started by column to 128 since it was not long
enough to hold the fully qualified class of a service that started a
flow.
* CORDA-3596 Remove arguments from in-memory checkpoint
When executing a flows first real suspend (from flow code) the arguments
contained in the `InvocationContext` are removed. This saves holding
these arguments for the whole lifecyle of a flow.
* CORDA-3596 Increase `cordapp_name` column to 128
* CORDA-3596 Join metadata by `flow_id`
Due to changes in where metadata is recorded, there is no need for
having `invocation_id` as the metadata table's primary key. The
`flow_id` is now the primary key of the table and is used to join to the
main checkpoints table.
The `invocation_id` has been removed from the checkpoints table since it
is not needed for the join anymore.
* CORDA-3596 Remove `received_time` from metadata table
* CORDA-3596 Remove unused `StartReason` enum
* CORDA-3596 Simple `DBCheckpointStorageTests` for metadata
* CORDA-3596 Truncate really long flow names