Flows that are kept for overnight observation:
- Save their Checkpoint.status as 'HOSPITALIZED' in the database
- Save the error that caused the hospitalization in the database
A new Event was added for this reason. Whenever the hospital determines
a flow for hospitalization, it adds this Event in the flow's fiber queue.
When processed it creates a new DB transaction, stores the checkpoint status along with
the error, and it adds a 'FlowContinuation.ProcessEvents' continuation so that the fiber keeps
processing events (effectively since there are no more events in the fiber's channel, the fiber will suspend).
Flows that error:
- Their checkpoints are kept in the database
- Save their Checkpoint.status as 'FAILED'
- Save the error that caused the error in the database
Upon erroring, the flow's Checkpoint.status gets updated('FAILED') and the checkpoint is stored
in the database instead of getting removed. The flow then propagates the error to counterparties,
sets its future with the error and gets removed from memory.
* ENT-4967: Require no classifier for corda-node-djvm, corda-deserializers-djvm.
* Also remove classifiers from core, serialization and finance-contracts.
* Compile corda-serialization-djvm for Java 8 and remove its classifier.
the current code doesn't forward the exception to the logging system, this means that any cause inside the exception is lost as with all of the stacktraces (both the one of the thrown exception and the one belonging to its cause).
The correct way to log an exception is to pass both the message and the exception to the logging system.
* CORDA-3690: Changed algorithm name used in signature from ECDSA to EC. JDK11 checks with in key generation.
* CORDA-3690: Remove the SHA512WITHSPHINCS256 signature scheme from the generate key pair and sign test.
* CORDA-3690: Algorithm in SignatureScheme has changed to EC from ECDSA so change test to match.
Co-authored-by: Adel El-Beik <adelel-beik@19LDN-MAC108.local>
Added a new field Completed to the in-memory object FlowState.
FlowState.Completed is corresponds to flow_state=Null in the DB.
This change will save disk space.
* Introduce CordaSessionFactoryFactory interface and the H2 implememntation
* Load SessionFactoryFactory via service loader
* Add Postgres SessionFactoryFactory
* Add extraConfiguration function for SessionFactoryFactory implementations to expose special config values.
* Run serialisation tests with both in-process and out-of-process nodes.
* Add custom serialisers and whitelists to Driver's AMQPServerSerializationScheme.
* Run serialisation tests with both in-process and out-of-process nodes.
* Add custom serialisers and whitelists to Driver's AMQPServerSerializationScheme.
* Stop capturing 'FlowLogic' references in flowAsyncOperation;
Creating concrete classes removes the implicit reference to FlowLogic (as this) being included in the anonymous object
* Modify test code so that lambdas no longer get implicit references to their enclosing 'FlowLogic'
* Stop capturing 'FlowLogic' references in flowAsyncOperation;
Creating concrete classes removes the implicit reference to FlowLogic (as this) being included in the anonymous object
* Modify test code so that lambdas no longer get implicit references to their enclosing 'FlowLogic'
* CORDA-3601 Record a flow's finish time
Record a flow's finish time by updating its metadata record. It is set
in `updateCheckpoint` by checking the status of the checkpoint. If it is
`COMPLETED` it will set the `finishInstant` on the metadata object and
update it.
* CORDA-3601 Record flow finish time for all finished statuses
Update the flow finish time for the following statuses:
- COMPLETED
- KILLED
- FAILED
* CORDA-3601 Use platform clock in `DBCheckpointStorage`
* CORDA-3669 Do not execute `ExecuteAsyncOperation` multiple times
When a `FlowExternalOperation` or `FlowExternalAsyncOperation` executes
and completes a flag (`isFlowResumed`) is switched to true.
This flag was used inside of `DoRemainingWorkTransition` to decide
whether to skip over the execution of an event.
Since this flag was being switched to true when the external operation's
future completed, it was possible for _unexpected_ events to be placed
in the fiber's queue that would retrigger the
`FlowIORequest.ExecuteAsyncOperation`, that is held as the checkpoint's
next `FlowIORequest`to process.
By using the existing `StateMachineState.isTransactionTracked` (and
renaming it to `isWaitingForFuture`) we can decide to not process the
`FlowIORequest.ExecuteAsyncOperation` if it has already been called
before. This moves this code path in line with
`FlowIORequest.WaitForLedgerCommit`.
Random `DoRemainingWork` events can now be pushed to the fiber's queue
without causing the `FlowIORequest.ExecuteAsyncOperation` to execute
again.
* CORDA-3668: Prevent AttachmentURLConnection from assigning ALL_PERMISSIONS to classes inside an attachment.
* Strengthen the comment warning about AttachmentURLConnection.getPermission.
* NOTICK Increase timeouts in external operation tests
It seems these tests are timing out when they shouldn't be when running
on the CI servers.
To resolve this, the timeouts of `getOrThrow` calls have been increased
to a minute.
Reliance on timeouts has also been reduced through using locks. This
should speed up tests that don't need to wait for the timeout anymore to
progress.
* NOTICK Remove hospital checking code
* NOTICK Change locking code