Fix wait-for-it script to work with external signals

The wait-for-it script used during tests would setup a timer
that would send SIGUSR2 to the parent process after the timer ends.
Since node was ignoring additional signals, the timer ending would have
no effect after the node process had replaced the start script. However
when node has pid != 1, SIGUSR2 default behavior is to terminate the
process, meaning the tests would fail after 30 seconds.

The script is now updated so the timer is killed once the services are
ready for the tests.
This commit is contained in:
Felipe Lalanne 2023-01-27 18:01:03 -03:00
parent 6683bca07d
commit 4d74505087

View File

@ -72,21 +72,18 @@ set_abort_timer() {
kill -USR2 "$2"
}
# Flag indicating whether the required services are ready
ready=0
abort_if_not_ready() {
# If the timeout is reached and the required services are not ready, it probably
# means something went wrong so we terminate the program with an error
if [ "${ready}" = "0" ]; then
echo "Something happened, failed to start in ${timeout}s" >&2
exit 1
fi
}
# Trap the signal and start the timer if user timeout is greater than 0
if [ "$timeout" -gt 0 ]; then
trap 'abort_if_not_ready' USR2
set_abort_timer "$timeout" $$ &
timer_pid=$!
fi
# Wait for docker
@ -110,7 +107,9 @@ if [ "${with_supervisor}" = "1" ]; then
done
fi
# Ignore signal if received
ready=1
# Kill the timer since we are ready to start
if [ "$timer_pid" != "" ]; then
kill $timer_pid
fi
exec ${cmd}